This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively.  相似文献   

2.
集热器测试系统利用两级温控,采用PID控制方法,把进水温度的漂移控制在±0.2℃以内;利用变频器采用位置式PID算法进行控制,将流量控制在±1%的精度范围内.对热管式真空管太阳能集热器进行了瞬时效率的测试,通过测试,证明了此种集热器热效率高,有广泛应用的前景.  相似文献   

3.
中建立太阳能驱劝的埃里克森热机系统的一般循环模型,探讨回热损失的内不可逆性因素对其循环效率和集热器最佳工作温度的影响,导出系统的最大效率和太阳能集热器的最佳工作温度,所得的结论对此类循环的研究提供新的理论依据。  相似文献   

4.
分析了换热器对集热器效率的影响,确定了换热器对集热器的削弱因子;提出了二次换热平板型太阳热水系统的能量方程。对自然循环二次换热平板型太阳热水系统系统的热性能进行了测试与分析,测试表明,自然循环二次换热平板型太阳热水器的平均日效率低于普通平板型太阳热水器,但高于真空管太阳热水器。  相似文献   

5.
为进一步提高太阳能利用效率和太阳能辅助空气源热泵供热系统的性能,提出了一种新型太阳能空气源热泵供热系统,并研究了该供热系统的性能和特性.基于自行设计的10kW空气源热泵,建立了供热系统的数学模型,通过模拟得出了不同环境温度和出水温度下供热系统的运行特性和性能规律.结果表明:基于新型太阳能辅助空气源热泵供热系统,热泵的性能得到较大的提高.当环境温度为7℃时,空气源热泵的COP最大可增加26%.这为进一步研究新型太阳能辅助空气源热泵供热系统在供暖季节的性能奠定了基础.  相似文献   

6.
分析福州地区典型气象年数据,表明该地区全年太阳辐射量和日照时数较大,太阳能和空气能资源较为优越。综合考虑入射太阳光余弦效应、太阳辐照量和热水负荷的变化,3种不同方法分别计算得到集热器最佳倾角,并比较分析倾角精确度及对应辅助加热量,最大限度地提高系统太阳能利用率,为实际太阳能热泵系统应用提供可靠理论支持。  相似文献   

7.
Parabolic trough collectors (PTCs) are employed for a variety of applications including steam generation and hot water generation. This paper deals with the experimental results and an economic analysis of a new fibre reinforced plastic (FRP) based solar PTC with an embedded electronic controlled tracking system designed and developed for hot water generation in a restaurant in Madurai, India. The new collector performance has been tested according to ASHRAE Standard 93 (1986). The performance of a new PTC hot water generation system with a well mixed hot water storage tank is investigated by a series of extensive tests over ten months period. The average maximum storage tank water temperature observed was 74.91℃, when no energy is withdrawn from the tank to the load during the collection period. The total cost of the new economic FRP based solar PTC for hot water generation with an embedded electronic controlled tracking system is Rs. 25000 (US$ 573) only. In the present work, life cycle savings (LCS) method is employed for a detailed economic analysis of the PTC system. A computer program is used as a tool for the economic analysis. The present worth of life cycle solar savings is evaluated for the new solar PTC hot water generation system that replaces an existing electric water heating system in the restaurant and attains a value of Rs. 23171.66 after 15 years, which is a significant saving. The LCS method and the MATLAB computer simulation program presented in this paper can be used to estimate the LCS of other renewable energy systems.  相似文献   

8.
太阳能供热采暖系统是指将太阳能转换成热能,供给建筑物冬季采暖和全年其他用热的系统。本研究提出了太阳能-空气源复合热源热泵系统,采用辅助加热炉为辅助热源和采用辅助热泵为辅助热源,系统由集热模块、控制模块、采暖模块组成,采用防过热选择性吸收涂层的集热器和防过热旁路散热器,解决了系统过热问题;同时对空气源热泵、辅助加热设备与太阳能集热器结合系统的运行性能进行了研究,优化了系统运行控制策略。  相似文献   

9.
INTRODUCTION Efforts of rational and effective energy man-agement, as well as environmental considerations, increase the interest in using renewable energy sources, especially solar energy. Because of discrep-ancy between the energy supply and demand in solar heating applications, a thermal energy storage (TES) device has to be used for the most effective utilization of the energy source. Energy storage combined with solar collectors and photovoltaic systems have been developed over the…  相似文献   

10.
水温是太阳能集热系统智能控制的核心信号源之一,其采集过程是太阳能集热系统控制的典型任务。针对当前水温检测采用两通道水温检测装置,由于通道太少,导致系统成本增加的问题,文中提出了研究多通道水温检测装置的方法,通过设计PIC单片机硬件电路、信号采集发送程序、仿真及调试,使多通道水温检测装置可根据用户需要采集多组水温数据,增强了太阳能集热系统的工程适应能力。  相似文献   

11.
以小型数据服务机房为研究对象,对机房使用列间空调后的气流组织进行了分析。利用CFD(流体动力学)软件对房间内的气体流动情况进行模拟,绘制温度、矢量风速计算云图,对比了冷通道封闭前后房间温度场、风场的变化,分析封闭前后室内换热情况。研究发现,冷通道封闭后离地0.5、1.5m处平均温度较封闭前平均温度下降2℃左右,机柜顶面下降1℃左右。封闭冷通道能够优化气流组织,有效避免气流短路,机房内局部热点消失,无效换热减少。  相似文献   

12.
介绍了一种应用于制冷空调领域的新型溶液除湿冷水机组,该系统可以由60~80℃的低品位热能驱动,如太阳能平板集热、余热废热等.对该系统建立了数学模型,理论分析了蒸发温度、再生温度、环境空气温湿度、封闭制冷循环和再生循环空气流量等参数对系统性能的影响.结果表明:系统在参考工况下制冷量为2.5kW,性能系数达0.37,制冷性能良好;再生温度和环境空气含湿量对系统制冷量和性能系数的影响较大,而环境空气温度的影响较小;同时,为了使得系统能够经济运行,再生空气流量不宜过大,而封闭制冷循环空气的流量也需要合理选择.  相似文献   

13.
菲涅尔跟踪式太阳能集热器是一根管的太阳能集热器,工作方式是在太阳能真空管下方放置许多条形镜面,通过微电脑的程序跟踪和光感跟踪结合的方式实现条形镜面将太阳光精确地反射聚焦到太阳能集热器上,从而实现太阳能的中温利用,提高太阳能热水器的热效.  相似文献   

14.
A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results,in which the solar collector was combined serially with a ground-coupled heat pump(GCHP).The universal optimal equations were solved by the constrained variable metric method considering both the performance and economics.Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating.The results indicated a system coefficient of performance(COP)of 3.9 for the optimal method under the seriaI heating mode,and 3.2 for the conventional one.In addition,the optimum solution also showed advantages in energy and cost saving.1eading to a 16.7%improvement in the heat pump performance at 17.2%less energy consumption and 11.8%lower annual cost,respectively.  相似文献   

15.
提出一种低倍瓦式聚光集热器,对其瓦式抛物面聚集器的结构设计、工作原理、光路传输进行理论分析。同时,基于数学推导和建模,通过MATLAB软件,理论模拟该集热器的几何特性、聚集性能等,并分析影响因素,对重要的设计参数进行优化研究。瓦式聚光集热器能将建筑屋顶空调节能与太阳能集热系统统一起来,对低成本高效太阳能热利用技术具有重要的意义。  相似文献   

16.
太阳能空间斯特林热机性能的优化分析   总被引:1,自引:0,他引:1  
建立太阳能驱动的空间斯特林热机的循环模型,应用有限时间热力学理论和太阳能集热器的辐射损失模型,研究受热阻和回热损失影响的太阳能斯特林热机循环性能,导出空间热机效率的基本优化关系,确定太阳能集热器的最佳工作温度和效率界限,讨论各种不可逆性对空间热机性能的影响,所得结论可为太阳能空间斯特林热机的优化设计提供新的理论指导。  相似文献   

17.
作者研究发的太阳能-空气双源热泵热水系统,将太阳能热泵与水蓄热结合,根据用户的需要和室外气象条件的变化,具有单独太阳能制热水、单独空气源制热水、制热水兼制冷、单独制冷、供暖等多种功能,可以节约能源,减少环境污染,是绿色建筑值得推广的一项技术。该系统运行稳定,能效比高,不但可以作为一项新技术在实际工程上推广,而且能够进行科研实验,又可供学生进行系统的测试、调试,作为教学仪器使用。  相似文献   

18.
关中西部冬小麦蒸发蒸腾与棵间蒸发试验研究   总被引:1,自引:0,他引:1  
小麦生育期内土壤蒸发平均约占总蒸发蒸腾量的32%,播种返青期是小麦生长的初期阶段,以蒸发耗水为主,蒸发平均约占总蒸发蒸腾量的65%;返青收获期以蒸腾耗水为主,蒸发平均仅占20%,但蒸发耗水量却与前期相差不大。减少棵间蒸发(E)对冬小麦水分利用率的提高有很重要的作用。  相似文献   

19.
用35~65℃恒温水浴对津春5号、新白玉、津研4号3个品种的黄瓜种子进行热击处理15-40min,结果表明45℃,20min处理津研4号种子的萌芽率明显升高,达到95%,平均株高和健壮度均较好;而45℃,30min处理津春5号与新白玉种子的效果较好.浸泡(8h)加热击(20min,45℃)依次处理以上3个品种的黄瓜种子,其萌芽率分别达到68.3%,74.7%和97.7%.表明适当温度和时间的热处理可以提高黄瓜种子的萌芽率.  相似文献   

20.
将热管系统的蒸发器作为连铸结晶器,通过测试蒸发室及熔融室内的温度,揭示热管运行温度和熔融室温度的关系。结果表明:在普通环境温度下和物质熔融温度为160℃时.热管工作温度为50-70℃,热管系统蒸发器面积和冷凝器面积之比从1:15增加到1:30时。热管工作温度降低较快,下降约23%;当面积比从1:30增加到1:60时,下降约8%:将热管系统运用于连铸生产时.增大热管系统的冷凝器面积,可以降低热管工作温度。但降低程度随面积比的增大而减小;当用于镁合金连铸时,热管的运行温度将超过100℃.  相似文献   