首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The purpose of this study was to quantify the reliability of kinematic and kinetic variables using a sample of pre-peak-height-velocity (PHV) male athletes sprinting on a non-motorised treadmill. Following variables were measured and their normative data presented, average and peak velocity, average and peak power, average and peak horizontal force, average and peak vertical force, average step frequency, average step length, average work. Twenty-five participants performed three 5-s all-out sprints from a standing split start on a non-motorised treadmill on three separate occasions. Per cent change in the means (-3.66 to 3.35%) and coefficients of variation (0.56–7.81%) were thought reliable for all variables. However, average step rate, average horizontal force and average vertical force did not meet the standards (≥0.70) set for acceptable intraclass correlation coefficients (ICC). Due to the homogeneous group, it was expected to receive low ICC values. Therefore, youth sprinting performance can be tested reliably on a non-motorised treadmill, especially if the per cent change in the mean and CV are deemed the important reliability measures. Normative data are given for the participant’s age as well as their maturity level for kinematic and kinetic variables.  相似文献   

2.
Eccentric contractions that provide spring energy can also cause muscle damage. The aim of this study was to explore leg and vertical stiffness following muscle damage induced by an eccentric exercise protocol. Twenty active males completed 60 minutes of backward-walking on a treadmill at 0.67 m/s and a gradient of ? 8.5° to induce muscle damage. Tests were performed immediately before; immediately post; and 24, 48, and 168 hours post eccentric exercise. Tests included running at 3.35 m/s and hopping at 2.2 Hz using single- and double-legged actions. Leg and vertical stiffness were measured from kinetic and kinematic data, and electromyography (EMG) of five muscles of the preferred limb were recorded during hopping. Increases in pain scores (over 37%) occurred post-exercise and 24 and 48 hours later (p < 0.001). A 7% decrease in maximal voluntary contraction occurred immediately post-exercise (p = 0.019). Changes in knee kinematics during single-legged hopping were observed 168 hours post (p < 0.05). No significant changes were observed in EMG, creatine kinase activity, leg, or vertical stiffness. Results indicate that knee mechanics may be altered to maintain consistent levels of leg and vertical stiffness when eccentric exercise-induced muscle damage is present in the lower legs.  相似文献   

3.
In-shoe plantar pressure systems are commonly used in clinical and research settings to assess foot function during functional tasks. Recently, Tekscan® has updated their F-Scan® in-shoe plantar pressure system; however, this system’s test–retest reliability has not been established. Therefore, the purpose of this study was to determine the test–retest reliability of the F-Scan® 7 system in recreationally active individuals during treadmill walking. Seventeen healthy adults completed 2 sessions of treadmill walking. For each session, participants were fitted for shoes and pressure insoles and walked on a treadmill at a self-selected pace for 30 s. Following the sessions, the test–retest reliability peak pressure, pressure time integral, average pressure and pressure contact area over 4 regions of the foot (heel, mid-foot, forefoot and toes) was assessed by calculating intraclass coefficients (ICC 2,k) and coefficient of variation percentage (CoV%). Pressure contact area consistently had the highest ICCs and lowest CoV% (ICCs: 0.91–0.98; CoV%: 2.7–7.8%). Whereas, the forefoot and toe regions had the highest ICCs for all 4 measures (ICCs: 0.83–0.98; CoV%: 3.1–13.4%). During treadmill walking in healthy recreationally active individuals, the reliability of the new Tekscan F-Scan® ranged from poor to high and was dependent on the measure and region of the foot.  相似文献   

4.
Research has focused on the effects of acute strike pattern modifications on lower extremity joint stiffness and running economy (RE). Strike pattern modifications on running biomechanics have mostly been studied while runners complete short running bouts. This study examined the effects of an imposed forefoot strike (FFS) on RE and ankle and knee joint stiffness before and after a long run in habitual rearfoot strike (RFS) runners. Joint kinetics and RE were collected before and after a long run. Sagittal joint kinetics were computed from kinematic and ground reaction force data that were collected during over-ground running trials in 13 male runners. RE was measured during treadmill running. Knee flexion range of motion, knee extensor moment and ankle joint stiffness were lower while plantarflexor moment and knee joint stiffness were greater during imposed FFS compared with RFS. The long run did not influence the difference in ankle and knee joint stiffness between strike patterns. Runners were more economical during RFS than imposed FFS and RE was not influenced by the long run. These findings suggest that using a FFS pattern towards the end of a long run may not be mechanically or metabolically beneficial for well-trained male RFS runners.  相似文献   

5.
This study analysed the modulation of jump performance, vertical stiffness as well as joint and intralimb coordination throughout a 30-s vertical jump test. Twenty male athletes performed the test on a force plate while undergoing kinematic analysis. Jump height, power output, ground contact time, vertical stiffness, maximum knee and hip flexion angles, and coordination by continuous relative phase (CRP) were analysed. Analysis of variance was used to compare variables within deciles, and t-tests were used to compare CRP data between the initial and final jumps. Results showed reduction in jump height, power output, and vertical stiffness, with an increase in contact time found during the test. Maximum knee and hip flexion angles declined, but hip angle decreased earlier (10–20% of the test) than knee angle (90–100%). No changes were observed in CRP for thigh–leg coupling when comparing initial and final jumps, but the trunk–thigh coupling was more in-phase near the end of the test. We conclude that fatigue causes reduction in jump performance, as well as changes in stiffness and joint angles. Furthermore, changes in intralimb coordination appear at the last 10% of the test, suggesting a neuromotor mechanism to counterbalance the loss of muscle strength.  相似文献   

6.
Little is known about the reliability, validity and smallest detectable differences of selected kinetic and temporal variables recorded by the Zebris FDM-THQ instrumented treadmill especially during running. Twenty male participants (age = 31.9 years (±5.6), height = 1.81 m (±0.08), mass = 80.2 kg (±9.5), body mass index = 24.53 kg/m2 (±2.53)) walked (5 km/h) and ran (10 and 15 km/h) on an instrumented treadmill, wearing running shoes fitted with Pedar-X insoles. A test-double retest protocol was conducted over two consecutive days. Maximal vertical force (Fmax), contact time (CT) and flight time (FT) data from 10 consecutive steps were collected. Within- and between-day reliability, smallest detectable differences (SDD) and validity (95% limits of agreement (LOA)) were calculated. ICC values for the Zebris for Fmax were acceptable (ICC ≥ 0.7) while CT and FT reliability indices were predominantly good (ICC ≥ 0.8) to excellent (ICC ≥ 0.9). The Zebris significantly underestimated Fmax when compared with the Pedar-X. The 95% LOA increased with speed. SDD ranged between 96 N and 169 N for Fmax, 0.017s and 0.055s for CT and 0.021s and 0.026s for FT. In conclusion, Zebris reliability was acceptable to excellent for the variables examined, but inferior in comparison with Pedar-X. With increased running speeds, a bias effect (underestimation) existed for the Zebris compared with Pedar-X.  相似文献   

7.
Ground reaction force measurements are a fundamental element of kinetic analyses of locomotion, yet they are traditionally constrained to laboratory settings or stationary frames. This study assessed the validity and reliability of a new wireless in-shoe system (Novel Loadsol/Pedoped) for field-based ground reaction force measurement in hopping, walking, and running. Twenty participants bilaterally hopped on a force plate and walked (5 km/hr) and ran (10 km/hr) on an instrumented treadmill on two separate days while wearing the insoles. GRFs were recorded simultaneously on each respective system. Peak GRF in hopping and peak GRF, contact time (CT), and impulse (IMP) in walking and running were compared on a per-hop and step-by-step basis. In hopping, the insoles demonstrated excellent agreement with the force plate (ICC: 0.96). In walking and running, the insoles demonstrated good-to-excellent agreement with the treadmill across all measures (ICCs: 0.88–0.96) and were reliable across sessions (ICCs within 0.00–0.03). A separate verification study with ten participants was conducted to assess a correction algorithm for further agreement improvement but demonstrated little meaningful change in systemic agreements. These results indicated that the Novel Loadsol system is a valid and reliable tool for wireless ground reaction force measurement in hopping, walking, and running.  相似文献   

8.
9.
ABSTRACT

Wearable resistance training involves added load attached directly to the body during sporting movements. The effects of load position during running are not yet fully established. Therefore, the purpose of this research was to determine spatio-temporal and kinetic characteristics during submaximal running using upper, lower and whole-body wearable resistance (1–10% body mass (BM)). Twelve trained male runners completed eight 2-min treadmill running bouts at 3.9 m/s with and without wearable resistance. The first and last bouts were unloaded, while the middle 6 were randomised wearable resistance conditions: upper body (UB) 5% BM, lower body (LB) 1%, 3%, 5% BM and whole body (WB) 5%, 10% BM. Wearable resistance of 1–10% BM resulted in a significant increase in heart rate (5.40–8.84%), but minimal impact on spatio-temporal variables. Loads of 5% BM and greater caused changes in vertical stiffness, vertical and horizontal force, and impulse. Functional and effective propulsive force (2.95%, 2.88%) and impulse (3.40%, 3.38%) were significantly (p < 0.05) greater with LB5% than UB5%. Wearable resistance may be used to increase muscular kinetics during running without negatively impacting spatio-temporal variables. The application of these findings will vary depending on athlete goals. Future longitudinal studies are required to validate training contentions.  相似文献   

10.
ABSTRACT

The purpose of this study was to investigate the effects of slope on three-dimensional running kinematics at high speed. Thirteen male sprinters ran at high speed (7.5 m/s) on a motorised treadmill in each a level and a 5.0% slope condition. Three-dimensional motion analysis was conducted to compare centre of mass (CoM) energetics, pelvis segment and lower limb joints kinematics. We found that contact time was not affected by the slope, whereas flight time and step length were significantly shorter in uphill compared to level running. Uphill running reduced negative CoM work and increased positive CoM work compared to level running. Ankle, knee and hip joints were more flexed at initial ground contact, but only the knee was more extended at the end of stance in uphill compared to level running. Additionally, the hip joint was more abducted, and the free leg side of the pelvis was more elevated at the end of stance in uphill running. Our results demonstrate that joint motion must be developed from a more flexed/adducted position at initial contact through a greater range of motion compared to level running in order to meet the greater positive CoM work requirements in uphill running at high speed.  相似文献   

11.
Weighted vests are widely used to improve running economy and performance. However, it is not well-studied how running mechanics are adapted to counteract the higher peak vertical ground reaction forces (Fpeak) while running with such a device. Therefore, the present study aimed to investigate the effects of different loading conditions on running mechanics at different velocities. Thirteen subjects participated in two separate sessions one week apart. In the first session, maximal aerobic speed (MAS) was determined through a maximal incremental running test while in the second session, they were instructed to run during one minute under different loading (0%, +10% and +20% of body mass [BM]) and velocity (60%, 80% and 100% of MAS) conditions in a random order. Spatiotemporal data were recorded and then running mechanics modelled using the spring-mass model. The main results indicated that vertical and leg stiffness (Kvert and Kleg, respectively) were increased (P?P?>?.05) when load was changed. At the same time, alterations of the running kinematics were observed such as longer contact times, reduced flight times, stride frequencies and step lengths, as well as an increase of the centre of mass dynamics. Based on these results it is assumed that runners maintain a certain stiffness level for each velocity despite different loading conditions. As a consequence, Fpeak increases and this probably causes spatiotemporal adjustments in the movement kinematics.  相似文献   

12.
Muscular power is important for maintaining physical functioning with aging. Proper quantification of the reliability of muscular power tests is crucial to inform monitoring of individuals and sample size planning for interventional studies. This study evaluated short- and long-term reliability of leg extensor power measurement in 72 adults (age 62.7 ± 8.6 years). Participants completed four repeat trials on the Nottingham leg extensor power rig, with a further trial twelve weeks later. Mean change, typical error, and intraclass correlation coefficients (ICC) were calculated. For short-term reliability, mean change in power output was trivial after two trials (1.2–4.8%). Typical errors were small following four trials in the dominant leg of males (10.9–5.8%), three in the non-dominant leg of males (9.9–6.2%) and the dominant leg of females (10.0–9.6%) and two in the non-dominant leg in females (8.3%). Intraclass correlation coefficients (ICCs) were very high (0.88–0.96). For long-term reliability, mean change remained trivial (1.0–2.5%), typical errors remained small (5.8–8.6%), and ICCs very high (0.94–0.96). The leg extensor power rig is a reliable method for assessing lower body muscular power, both short- and long-term, with only minimal habituation effects.  相似文献   

13.
目的:确定跑步疲劳进程中下肢生物力学模式的变化,包括垂直和前后地面反作用力(ground reaction force,GRF)、垂直地面反作用力(vertical ground reaction force,vGRF)负载率、关节力学和刚度。方法:14名男性受试,采用Vicon红外摄像头和Bertec三维测力跑台,每隔2 min采集受试疲劳干预中的15 s GRF数据以及标记点轨迹。受试需穿着统一的跑鞋在测力跑台以恒速3.33 m/s跑至疲劳。满足以下标准时,干预结束:1)最大心率大于当下年龄的90%;2)受试不能继续跑步。对比受试跑至疲劳进程中4个时刻(疲劳前、33%、67%和100%)的着地冲击和下肢三关节触地角度、最大角度、关节活动度、角度变化量、关节蹬伸力矩和刚度等特征,采集并分析受试安静状态、疲劳后即刻、疲劳后4 min、疲劳后9 min的血乳酸浓度。结果:与疲劳前相比,1)血乳酸浓度在疲劳后即刻、疲劳后4 min和疲劳后9 min均显著增加;2)垂直/前后矢状轴GRF和vGRF负载率等参数在疲劳干预过程中均未观察到显著性变化;3)髋关节活动度在疲劳过程的33%、67%和100%时刻显著增加,膝关节活动度在67%时刻显著增加;4)踝关节运动学及踝、膝和髋关节的蹬伸力矩峰值均无变化;5)垂直刚度在67%和100%时刻显著降低。结论:疲劳干预过程中,GRF特征参数均没有明显变化,但是观察到下肢运动学和动力学模式的非线性改变。特别是从疲劳干预中期开始,人体下肢通过增加髋、膝关节活动度并减小垂直刚度实现“软着陆”策略,维持相似的冲击力特征,以减小长时间跑步可能带来损伤的风险。  相似文献   

14.
This study investigated the reliability of a wireless accelerometer and its agreement with optical motion capture for the measurement of root mean square (RMS) acceleration during running. RMS acceleration provides a whole-body metric of movement mechanics and economy. Fifteen healthy college-age participants performed treadmill running for two 60-s trials at 2.22, 2.78, and 3.33 m/s and one trial of 150 s (five 30-s epochs) at 2.78 m/s. We assessed between-trial and within-trial reliability, and agreement in each axis between a trunk-mounted wireless accelerometer and a reflective marker on the accelerometer measured by optical motion capture. Intraclass correlations assessing between-trial repeatability were 0.89–0.97, depending on the axis, and intraclass correlations assessing within-trial repeatability were 0.99–1.00. Bland–Altman analyses assessing agreement indicated mean difference values between ?0.03 and 0.03 g, depending on the axis. Anterio-posterior acceleration had the greatest limits of agreement (LOA) (±0.12 g) and vertical acceleration had the smallest LOA (±0.03 g). For measuring RMS acceleration of the trunk, this wireless accelerometer node provides repeatable and valid measurement compared with the standard laboratory method of optical motion capture.  相似文献   

15.
Comparison of maximal anaerobic running tests on a treadmill and track   总被引:1,自引:0,他引:1  
To develop a track version of the maximal anaerobic running test, 10 sprint runners and 12 distance runners performed the test on a treadmill and on a track. The treadmill test consisted of incremental 20-s runs with a 100-s recovery between the runs. On the track, 20-s runs were replaced by 150-m runs. To determine the blood lactate versus running velocity curve, fingertip blood samples were taken for analysis of blood lactate concentration at rest and after each run. For both the treadmill and track protocols, maximal running velocity (v max), the velocities associated with blood lactate concentrations of 10 mmol x l-1 (v10 mM) and 5 mmol x l(-1) (v5 mM), and the peak blood lactate concentration were determined. The results of both protocols were compared with the seasonal best 400-m runs for the sprint runners and seasonal best 1000-m time-trials for the distance runners. Maximal running velocity was significantly higher on the track (7.57 +/- 0.79 m x s(-1)) than on the treadmill (7.13 +/- 0.75 m x s(-1)), and sprint runners had significantly higher vmax, v10 mM, and peak blood lactate concentration than distance runners (P < 0.05). The Pearson product--moment correlation coefficients between the variables for the track and treadmill protocols were 0.96 (v max), 0.82 (v10 mM), 0.70 (v5 mM), and 0.78 (peak blood lactate concentration) (P < 0.05). In sprint runners, the velocity of the seasonal best 400-m run correlated positively with vmax in the treadmill (r = 0.90, P < 0.001) and track protocols (r = 0.92, P < 0.001). In distance runners, a positive correlation was observed between the velocity of the 1000-m time-trial and vmax in the treadmill (r = 0.70, P < 0.01) and track protocols (r = 0.63, P < 0.05). It is apparent that the results from the track protocol are related to, and in agreement with, the results of the treadmill protocol. In conclusion, the track version of the maximal anaerobic running test is a valid means of measuring different determinants of sprint running performance.  相似文献   

16.
Drop jumping has previously been used to measure fast stretch shorten cycle (SSC) ability and stretch load tolerance. To the knowledge of these authors a test does not exist to achieve this in the horizontal direction. The purpose of this study therefore was to estimate the reliability of a new unilateral horizontal leg power test to assess these qualities. Participants (N = 10) performed three jumps on each leg from distances of 80%, 120%, and 160% of leg length onto a force plate, followed immediately by a jump for maximal distance onto a synthetic track. No significant between- leg differences (p > .05) were found for the dependent variables of ground contact time (GCT), peak propulsive vertical ground reaction force, peak propulsive horizontal ground reaction force, and distances jumped (DJ).Within-trial variability (coefficients of variation) ranged from 3.6% to 10.9%, and test-retest reliability intraclass correlation coefficients from 0.80 to 0.95. GCT and DJ were the variables with highest reliability between trials and days. These two variables should be used to indicate fast SSC (GCT) ability and stretch load tolerance (DJ-GCT) in the horizontal direction. The relationship of these measures to functional performance needs to be established.  相似文献   

17.
Abstract

High ground reaction forces during the front foot contact phase of the bowling action are believed to be a major contributor to the high prevalence of lumbar stress fractures in fast bowlers. This study aimed to investigate the influence of front leg technique on peak ground reaction forces during the delivery stride. Three-dimensional kinematic data and ground reaction forces during the front foot contact phase were captured for 20 elite male fast bowlers. Eight kinematic parameters were determined for each performance, describing run-up speed and front leg technique, in addition to peak force and time to peak force in the vertical and horizontal directions. There were substantial variations between bowlers in both peak forces (vertical 6.7 ± 1.4 body weights; horizontal (braking) 4.5 ± 0.8 body weights) and times to peak force (vertical 0.03 ± 0.01 s; horizontal 0.03 ± 0.01 s). These differences were found to be linked to the orientation of the front leg at the instant of front foot contact. In particular, a larger plant angle and a heel strike technique were associated with lower peak forces and longer times to peak force during the front foot contact phase, which may help reduce the likelihood of lower back injuries.  相似文献   

18.
Abstract

The ‘stiffness’ concept originates from Hooke's law which states that the force required to deform an object is related to a spring constant and the distance that object is deformed. Research into stiffness in the human body is undergoing unprecedented popularity; possibly because stiffness has been associated with sporting performance and some lower limb injuries. However, some inconsistencies surrounding stiffness measurement exists bringing into question the integrity of some research related to stiffness. The aim of this study was to review literature which describes how vertical, leg and knee stiffness has been measured in adult populations while running, jumping or hopping. A search of the entire MEDLINE, PubMed and SPORTDiscus databases and an iterative reference check was performed. Sixty-seven articles were retrieved; 21 measured vertical stiffness, 51 measured leg stiffness, and 22 measured knee stiffness. Thus, some studies measured several ‘types’ of stiffness. Vertical stiffness was typically the quotient of ground reaction force and centre of mass displacement. For leg stiffness it was and change in leg length, and for the knee it was the quotient of knee joint moments and change in joint angle. Sample size issues and measurement techniques were identified as limitations to current research.  相似文献   

19.
The aim of this study was to assess the validity (Study 1) and reliability (Study 2) of a novel intermittent running test (Carminatti's test) for physiological assessment of soccer players. In Study 1, 28 players performed Carminatti's test, a repeated sprint ability test, and an intermittent treadmill test. In Study 2, 24 players performed Carminatti's test twice within 72 h to determine test-retest reliability. Carminatti's test required the participants to complete repeated bouts of 5 × 12 s shuttle running at progressively faster speeds until volitional exhaustion. The 12 s bouts were separated by 6 s recovery periods, making each stage 90 s in duration. The initial running distance was set at 15 m and was increased by 1 m at each stage (90 s). The repeated sprint ability test required the participants to perform 7 × 34.2 m maximal effort sprints separated by 25 s recovery. During the intermittent treadmill test, the initial velocity of 9.0 km · h(-1) was increased by 1.2 km · h(-1) every 3 min until volitional exhaustion. No significant difference (P > 0.05) was observed between Carminatti's test peak running velocity and speed at VO(2max) (v-VO(2max)). Peak running velocity in Carminatti's test was strongly correlated with v-VO(2max) (r = 0.74, P < 0.01), and highly associated with velocity at the onset of blood lactate accumulation (r = 0.63, P < 0.01). Mean sprint time was strongly associated with peak running velocity in Carminatti's test (r = -0.71, P < 0.01). The intraclass correlation was 0.94 with a coefficient of variation of 1.4%. In conclusion, Carminatti's test appears to be avalid and reliable measure of physical fitness and of the ability to perform intermittent high-intensity exercise in soccer players.  相似文献   

20.
Improving sedentary measurement is critical to understanding sedentary-health associations in youth. This study assessed agreement between the thigh-worn activPAL and commonly used hip-worn ActiGraph accelerometer methods for assessing sedentary patterns in children. Both devices were worn by 8–12-year-olds (N = 195) for 4.6 ± 1.9 days. Two ActiGraph cut-points were applied to two epoch durations: ≤25 counts (c)/15 s, ≤75c/15s, ≤100c/60s, and ≤300c/60s. Bias, mean absolute deviation (MAD), and intraclass correlation coefficients (ICCs) tested agreement between devices for total sedentary time and 11 sedentary pattern variables (usual bout duration, sedentary time accumulated in various bout durations, breaks/day, break rate, and alpha). For most sedentary pattern variables, ActiGraph 25c/15s, 75c/15s, and 100c/60s had poor ICCs, with bias and MAD >20%. ActiGraph 300c/60s had a better agreement than the other cut-points, but all ICCs were <0.587. ActiGraph underestimated sedentary time in longer bouts and usual bout duration, and overestimated sedentary time in shorter bouts, breaks/day, and alpha. For total sedentary time, ActiGraph 25c/15s, 300c/60s, and 75c/15s had good/fair ICCs, with bias and MAD <20%. Sedentary patterns derived from two commonly used ActiGraph cut-points did not appear to reflect postural changes. These differences between measurement devices should be considered when interpreting findings from sedentary pattern studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号