Introduction:

In this work we report on the possible effect of the medical therapy on CDT concentration in a chronic alcohol abuser, with known medical history (July 2007 – April 2012) and alcohol abuse confirmed by relatives.

Case history:

At the end of 2007, patient displayed the following laboratory results: AST 137 U/L, ALT 120 U/L, GGT 434 U/L, MCV 101 fL and CDT 3.3%. On December 2007, after double coronary artery bypass surgery, he began a pharmacological treatment with amlodipine, perindopril, atorvastatin, isosorbide mononitrate, carvedilol, ticlopidine and pantoprazole. In the next months, until may 2011, the patient resumed alcohol abuse, as confirmed by relatives; however, CDT values were repeatedly found negative (0.8% and 1.1%) despite elevated transaminases and GGT, concurrent elevated ethyl glucuronide concentration (> 50 mg/L) and blood alcohol concentration (> 1 g/L). Alcohol consumption still continued despite increasing disulfiram doses ordered by an Alcohol Rehab Center. On May 2011, the patient was transferred to a private medical center where he currently lives.

Conclusions:

This study suggests the possibility that a medical therapy including different drugs may hamper the identification of chronic alcohol abusers by CDT.  相似文献   

3.

Background

Short-chain acyl-CoA dehydrogenase deficiency (SCADD) is a rare inherited mitochondrial fatty acid oxidation disorder associated with variations in the ACADS (Acyl-CoA dehydrogenase, C-2 to C-3 short chain) gene. SCADD has highly variable biochemical, genetic and clinical characteristics. Phenotypes vary from fatal metabolic decompensation to asymptomatic individuals.

Subject and methods

A Romani boy presented at 3 days after birth with hypoglycaemia, hypotonia and respiratory pauses with brief generalized seizures. Afterwards the failure to thrive and developmental delay were present. Organic acids analysis with gas chromatography-mass spectrometry (GS/MS) in urine and acylcarnitines analysis with liquid chromatography-tandem mass spectrometry (LC-MS/MS) in dried blood spot were measured. Deoxyribonucleic acid (DNA) was isolated from blood and polymerase chain reactions (PCRs) were performed for all exons. Sequence analysis of all exons and flanking intron sequences of ACADS gene was performed.

Results

Organic acids analysis revealed increased concentration of ethylmalonic acid. Acylcarnitines analysis showed increase of butyrylcarnitine, C4-carnitine. C4-carnitine was 3.5 times above the reference range (<0.68 µmol/L). Confirmation analysis for organic acids and acylcarnitine profile was performed on the second independent sample and showed the same pattern of increased metabolites. Sequence analysis revealed 3-bp deletion at position 310-312 in homozygous state (c.310_312delGAG). Mutation was previously described as pathogenic in heterozygous state, while it is in homozygous state in our patient.

Conclusions

In our case clinical features of a patient, biochemical parameters and genetic data were consistent and showed definitely SCAD deficiency.Key words: SCAD deficiency, short chain acyl-CoA dehydrogenase deficiency, screening, acylcarnitine, polymorphism, genetic  相似文献   

4.

Background

The preanalytical phase represents the major source of variability in laboratory diagnostics. Our aim was to assess to what extent underfilling of primary blood tubes may impact upon routine coagulation testing.

Materials and methods:

Blood was drawn by syringe from 21 healthy volunteers and 6 patients on warfarin therapy, and immediately transferred into 3.6 mL vacuum tubes containing 3.2% sodium citrate (Terumo Europe N.V., Leuven, Belgium). All tubes were filled using standardized volumes of whole blood to produce scalar amounts of filling: 3.6 mL (i.e., 100%), 3.2 mL (89%), 2.8 mL (78%) and 2.4 mL (67%). Samples were mixed and centrifuged at 1300 × g for 10 min. The plasma was tested for prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FBG) on ACL TOP (Instrumentation Laboratory - IL, Milan, Italy), using IL reagents. A polynomial plot was derived for each parameter from interpolation of clotting values obtained with different percentages of filling, and these plots were compared with quality specifications (± 2.0 for PT, ± 2.3 for APTT and ± 4.8 for FBG) to calculate the minimal filling volume required to produce clinically acceptable results.

Results:

The equations were (PF, Percentage of filling): PT (sec) = 3.375 × PF^2–6.255 × PF + 17.806 (r = 0.980); APTT (sec) = 8.925 × PF^2–23.578 × PF + 46.356 (r = 0.979); and FBG (mg/dL) = −311.5 × PF^2 + 422.1 × PF + 147.07 (r = 0.994). According to these equations, the minimum allowed thresholds of blood tubes filling were > 61% for PT, > 87% for APTT and > 71% for FBG.

Conclusions:

Our results confirm that routine coagulation testing performed on underfilled tubes may generate biased and clinically misleading test results. This is particularly critical for APTT, wherein tubes filled at less than ∼90% generate unreliable data. The FBG and the PT seem more resistant to underfilling, clinical significant biases being observed only where blood tubes were filled at less than ∼60 and ∼70%, respectively.  相似文献   

5.

Background:

Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests.

Materials and methods:

A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV).

Results:

A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104–117) and 111 (107–120) vs. 109 (102–118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9–34.8) vs. 34.1 (32.2–35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV.

Conclusion:

A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.  相似文献   

6.

Introduction:

We present our work of monitoring 202 different patients with markedly elevated serum index for lipemia whereby serum samples were clear. We tried to clarify the cause of occurrence of these indices which were detected in the years 2006–2010 on Siemens Dimension analyzers.

Materials and methods:

In samples with unusual lipemia index we measured the concentration of lipids (total cholesterol, triglycerides, HDL and LDL cholesterol, Lp(a), ApoA1, ApoB), total proteins and checked for possible interferents (rheumatoid factor, immunoglobulins). We performed serum protein and immuno- electrophoresis. We investigated the repeatability of unusual lipemia indices during the day and after different time periods and we compared them on four different analyzers (RXL Max, Vista, Hitachi 911 and former Olympus AU640).

Results:

In 87% of 202 samples we found a monoclonal or biclonal peak in serum protein electrophoresis. Different types of paraproteins were confirmed with immunofixation electrophoresis. In the remaining 13%, polyclonal elevated concentrations of immunoglobulins were measured. Other parameters had no influence on appearing of these indices. The repeatability of indices was good during the first day of measurements (P values > 0.05) and markedly lower in the next days or after 3 and 12 months (P values < 0.05). The indices were elevated only on Dimension analyzers, but not on Hitachi and former Olympus analysers.

Conclusion:

A markedly elevated lipemia index in a clear serum sample measured on Siemens analyzers Dimension indicates a high possibility for the presence of a paraprotein in the sample.  相似文献   

7.

Background

In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

Material and methods

Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.

Results

The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).

Conclusion

Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume  相似文献   

8.

Introduction:

The measurement of cardiospecific troponins is pivotal in the diagnostic and prognostic approach of patients with suspected acute myocardial infarction (AMI). However, no information is available on the commutability of results between the novel highly-sensitive (HS) troponin T (TnT) and I (TnI) immunoassays.

Materials and methods:

The study population consisted in 47 consecutive patients presenting at the emergency department (ED) of the Academic Hospital of Parma with suspected AMI. TnI was measured with the novel prototype Beckman Coulter HS-AccuTnI immunoassay on Access 2, whereas TnT was measured with the Roche HS-TnT immunoassay on Cobas.

Results:

Eight out of the 47 patients (17%) were finally diagnosed as having an AMI. The overall correlation between TnT and TnI for total patient group was acceptable (r = 0.944; P < 0.01). Nevertheless, when the analysis of data was carried out in separate groups according to the final diagnosis of AMI, two different equation results were obtained, i.e., HS-TnT = HS-AccuTnI × 0.349 + 20 (r = 0.823; P < 0.01) in non-AMI patients, and HS-TnT = HS-AccuTnI × 0.134 + 67 (r = 0.972; P < 0.01) in those with AMI.

Conclusions:

This study suggests the existence of two biological relationships between TnI and TnT in plasma, depending on the source of release from the myocardium. Moreover, the non-commutability of data between HS-TnT and HS-AccuTnI jeopardizes the clinical decision making, makes it impossible to calculate the delta or reference change value using the two biomarkers and to finally establish a reliable kinetics of troponin release from the injured myocardium.  相似文献   

9.
10.

Introduction:

We examined the cost-effectiveness of the three different D-dimer measurements in the screening of DVT in models with and without calculation of pre-test probability (PTP) score. Moreover, we calculated the minimal cost in DVT detection.

Material and methods:

In the group of 192 patients with clinically suspected acute DVT, we examined the three different D-dimer measurements (Innovance D-dimer, Hemosil D-dimer HS and Vidas D-dimer Exclusion II) in combination with and without PTP assessment.

Results:

The diagnostic alternative employing Vidas D-dimer Exclusion II assay without and with PTP calculation gave lower incremental cost-effectiveness ratio (ICER) than the alternative employing Hemosil D-dimer HS assay (0.187 Euros vs. 0.998 Euros per one additional DVT positive patient selected for CUS in model without PTP assessment and 0.450 vs. 0.753 Euros per one DVT positive patient selected for CUS in model with PTP assessment). According to sensitivity analysis, the Hemosil D-dimer HS assay was the most cost effective alternative when one patient was admitted to the vascular ambulance per day. Vidas D-dimer Exclusion II assay was the most cost effective alternative when more than one patient were admitted to the vascular ambulance per day. Cost minimisation analysis indicated that selection of patients according to PTP score followed by D-dimer analysis decreases the cost of DVT diagnosis.

Conclusions:

ICER analysis enables laboratories to choose optimal laboratory tests according to number of patients admitted to laboratory. Results support the feasibility of using PTP scoring and D-dimer measurement before CUS examination in DVT screening.  相似文献   

11.

Aim:

The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups.

Materials and methods:

In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males).

Results:

Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males < 50 yrs were significantly overrepresented when compared with the non-AB groups (P = 0.003).

Conclusions:

No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.  相似文献   

12.

Introduction:

Blood collection through intravenous lines frequently causes spurious hemolysis. Due to specific structure, the tube holder Holdex® (Greiner Bio-One GmbH, Kremsmuenster, Austria) is supposed to prevent erythrocyte injury in samples collected from catheters, so that we planned a specific study to support this hypothesis.

Materials and methods:

Blood was collected from emergency department (ED) patients with 20-gauge catheter. In patients with odd order numbers, first and second tubes were collected with conventional holder (BD Vacutainer One Use Holder, Becton Dickinson, Milan, Italy) and the third with Holdex, whereas in even patients first and second tubes were drawn with Holdex and the third using BD Vacutainer One Use Holder. The first tube was discarded, whereas the second and third were centrifuged and serum was tested for potassium, lactate dehydrogenase (LD) and hemolysis index.

Results:

The final study population consisted in 60 ED patients. Concentrations of potassium (4.25 vs. 4.16 mmol/L; P = 0.031), LD (498 vs. 459 U/L; P = 0.039) and cell-free hemoglobin (0.42 vs. 0.22 g/L; P = 0.042) were higher in samples collected with BD Vacutainer One Use Holder than with Holdex. The mean bias of cell-free hemoglobin was −0.4 g/L in samples collected with Holdex. Although the frequency of samples with cell-free hemoglobin > 0.5 g/L was identical (17/60 vs. 17/60; P = 1.00), the frequency of those with concentrations >3.0 g/L was higher using BD Vacutainer One Use Holder than Holdex (4/60 vs. 0/60; P = 0.042).

Conclusions:

The use of Holdex for drawing blood from intravenous lines may be effective for reducing gross hemolysis.  相似文献   

13.

Introduction

Although prostatitis is a common male urinary tract infection, clinical diagnosis of prostatitis is difficult. The developmental mechanism of prostatitis is not yet unraveled which led to the elaboration of various biomarkers. As changes in asparagine-linked-(N-)-glycosylation were observed between healthy volunteers (HV), patients with benign prostate hyperplasia and prostate cancer patients, a difference could exist in biochemical parameters and urinary N-glycosylation between HV and prostatitis patients. We therefore investigated if prostatic protein glycosylation could improve the diagnosis of prostatitis.

Materials and methods

Differences in serum and urine biochemical markers and in total urine N-glycosylation profile of prostatic proteins were determined between HV (N = 66) and prostatitis patients (N = 36). Additionally, diagnostic accuracy of significant biochemical markers and changes in N-glycosylation was assessed.

Results

Urinary white blood cell (WBC) count enabled discrimination of HV from prostatitis patients (P < 0.001). Urinary bacteria count allowed for discriminating prostatitis patients from HV (P < 0.001). Total amount of biantennary structures (urinary 2A/MA marker) was significantly lower in prostatitis patients compared to HV (P < 0.001). Combining the urinary 2A/MA marker and urinary WBC count resulted in an AUC of 0.79, 95% confidence interval (CI) = (0.70–0.89) which was significantly better than urinary WBC count (AUC = 0.70, 95% CI = [0.59–0.82], P = 0.042) as isolated test.

Conclusions

We have demonstrated the diagnostic value of urinary N-glycosylation profiling, which shows great potential as biomarker for prostatitis. Further research is required to unravel the developmental course of prostatic inflammation.Key words: diagnostic marker, prostatitis, urinary asparagine-linked glycosylation  相似文献   

14.
15.

Introduction

Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC).

Materials and methods

We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square.

Results

There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients.

Conclusion

We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system.Key words: Preanalytical phase, errors in laboratory medicine, balanced scorecard, patient safety  相似文献   

16.

Introduction

The educational program for health care personnel is important for reducing preanalytical errors and improving quality of laboratory test results. The aim of our study was to assess the level of knowledge on preanalytical phase in population of biomedicine students through a cross-sectional survey.

Materials and methods

A survey was sent to students on penultimate and final year of Faculty of Pharmacy and Biochemistry – study of medical biochemistry (FPB), Faculty of Veterinary Medicine (FVM) and School of Medicine (SM), University of Zagreb, Croatia, using the web tool SurveyMonkey. Survey was composed of demographics and 14 statements regarding the preanalytical phase of laboratory testing. Comparison of frequencies and proportions of correct answers was done with Fisher’s exact test and test of comparison of proportions, respectively.

Results

Study included 135 participants, median age 24 (23-40) years. Students from FPB had higher proportion of correct answers (86%) compared to students from other biomedical faculties 62%, P < 0.001. Students from FPB were more conscious of the importance of specimen mixing (P = 0.027), prevalence of preanalytical errors (P = 0.001), impact of hemolysis (P = 0.032) and lipemia interferences (P = 0.010), proper choice of anticoagulants (P = 0.001), transport conditions for ammonia sample (P < 0.001) and order of draw during blood specimen collection (P < 0.001), in comparison with students from SM and FVM.

Conclusions

Students from FPB are more conscious of the importance of preanalytical phase of testing in comparison with their colleagues from other biomedical faculties. No difference in knowledge between penultimate and final year of the same faculty was found.Key words: survey, education, preanalytical phase  相似文献   

17.

Introduction

The aim of this study was to identify clinical variables which may be independently associated with positivity of a cardiac troponin I (cTnI) assay in a large population of patients admitted to the emergency department (ED).

Materials and methods

3166 subjects, with at least two troponin I tests ordered within 6 hours in the ED, were studied. Patient data were statistically analyzed to identify clinical associations with increased values of Troponin I.

Results

Although patients with diagnosis of acute coronary syndrome displayed troponin I values significantly higher than those of other groups, positivity to troponin I (> 40 ng/L) was also observed in patients with other clinical conditions. In multivariate analysis, age, elevated heart rate and electrocardiographyc changes were independently associated with troponin I positivity at admission. In the whole study population troponin I positivity exhibited high sensitivity and negative predictive value, counterbalanced by low specificity and limited positive predictive value.

Conclusions

Troponin I positivity should be combined with history and clinical evaluation and cautiously interpreted in the ED, especially in patients exhibiting factors associated with higher troponin I levels such as older age, elevated heart rate or ECG changes.Key words: troponin I, acute coronary syndrome, emergency service, hospital, chest pain  相似文献   

18.

Introduction

Sparse data are available about the effect of therapy methods on antibody levels in patients with liver failure. The aim of this study was to determine serum immunoglobulin concentrations in patients with chronic hepatic failure (CHF), acute- (ALF), or acute-on-chronic liver failure (ACLF) and to evaluate the impact of MARS treatment or liver transplantation (LT) on antibody levels.

Materials and methods

We followed ten patients with ALF, twelve with ACLF and 18 with CHF. Eight patients with ALF and seven with ACLF underwent MARS therapy, whereas the rest received LT. 13 healthy volunteers served as controls. Serum antibody concentrations were measured using ELISA-technique.

Results

Median serum levels of IgA, IgG and IgM were significantly increased in patients with CHF compared to ALF or controls (P < 0.02, P < 0.01, and P < 0.01). IgM and IgG concentrations were also significantly elevated in patients with CHF compared to ACLF (IgM, 3.7 vs. 1 g/L, P < 0.001; IgG, 8.7 vs. 3.1 g/L, P = 0.004). Immediately after LT a significant decrease of IgA (6.9 vs. 3.1 g/L, P = 0.004), IgG (8.7 vs. 5.1 g/L, P = 0.02) and IgM (3.7 vs. 1.8 g/L, P = 0.001) was detected in patients with CHF and antibody levels further decreased the days after LT reaching levels comparable to healthy individuals. MARS treatment had no apparent effect on the immunoglobulin profile in patients with ALF or ACLF.

Conclusion

We provide evidence that LT reverses hypergammaglobulinemia in patients suffering from CHF within one day, which could be explained to a reconstituted hepatic antibody clearance, whereas MARS treatment has no immediate effect on immunoglobulin levels.Key words: antibodies, immunoglobulins, liver failure, liver transplantation, artificial liver support system, molecular adsorbent recirculating system  相似文献   

19.

Background:

In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the “vacuum” or “aspiration” mode.

Materials and methods:

The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC.

Results:

In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error.

Conclusions:

Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.  相似文献   

20.

Introduction

Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L.

Materials and methods

Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically.

Results

Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference.

Conclusion

Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.Key words: assay interference, glucose interference, preanalytical phase, creatinine, Jaffe kinetic assay, thyroid function tests  相似文献   