Wearable activity trackers have become popular for tracking individual’s daily physical activity, but little information is available to substantiate the validity of these devices in step counts. Thirty-five healthy individuals completed three conditions of activity tracker measurement: walking/jogging on a treadmill, walking over-ground on an indoor track, and a 24-hour free-living condition. Participants wore 10 activity trackers at the same time for both treadmill and over-ground protocol. Of these 10 activity trackers three were randomly given for 24-hour free-living condition. Correlations of steps measured to steps observed were r?=?0.84 and r?=?0.67 on a treadmill and over-ground protocol, respectively. The mean MAPE (mean absolute percentage error) score for all devices and speeds on a treadmill was 8.2% against manually counted steps. The MAPE value was higher for over-ground walking (9.9%) and even higher for the 24-hour free-living period (18.48%) on step counts. Equivalence testing for step count measurement resulted in a significant level within ±5% for the Fitbit Zip, Withings Pulse, and Jawbone UP24 and within ±10% for the Basis B1 band, Garmin VivoFit, and SenseWear Armband Mini. The results show that the Fitbit Zip and Withings Pulse provided the most accurate measures of step count under all three different conditions (i.e. treadmill, over-ground, and 24-hour condition), and considerable variability in accuracy across monitors and also by speeds and conditions.  相似文献   

2.
ABSTRACT

The aims of this study were to estimate the walking cadence required to elicit a VO2reserve (VO2R) of 40% and determine if fitness status moderates the relationship between walking cadence and %VO2R. Twenty participants (10 male, mean(s) age 32(10) years; VO2max 45(10) mL·kg?1·min?1) completed resting and maximal oxygen consumption tests prior to 7 x 5-min bouts of treadmill walking at increasing speed while wearing an Apple Watch and measuring oxygen consumption continuously. The 7 x 5-min exercise bouts were performed at speeds between 3 and 6 km·h?1 with 5-min seated rest following each bout. Walking cadence measured at each treadmill speed was recorded using the Apple Watch “Activity” app. Using Bayesian regression, we predict that participants need a walking cadence of 138 to 140 steps·min?1 to achieve a VO2R of 40%. However, these values are moderated by fitness status such that those with lower fitness can achieve 40% VO2R at a slower walking cadence. The results suggest that those with moderate fitness need to walk at ~40% higher than the currently recommended walking cadence (100 steps·min?1) to elicit moderate-intensity physical activity. However, walking cadence required to achieve moderate-intensity physical activity is moderated by fitness status.  相似文献   

3.
Abstract

The purpose of this study was to validate peak acceleration data from an accelerometer contained within a wearable tracking device while walking, jogging and running. Thirty-nine participants walked, jogged and ran on a treadmill while 10 peak accelerations per movement were obtained (n = 390). A single triaxial accelerometer measured resultant acceleration during all movements. To provide a criterion measure of acceleration, a 12-camera motion analysis (MA) system tracked the position of a retro-reflective marker affixed to the wearable tracking device. Peak raw acceleration recorded by the accelerometer significantly overestimated peak MA acceleration (P < 0.01). Filtering accelerometer data improved the relationship with the MA system (P < 0.01). However, only the 10 Hz and 8 Hz cut-off frequencies significantly reduced the errors found. The walk movement demonstrated the highest accuracy, agreement and precision and the lowest relative errors. Linear increases in error were observed for jog compared with walk and for run compared to both other movements. As the magnitude of acceleration increased, the strength of the relationship between the accelerometer and the criterion measure decreased. These results indicate that filtered accelerometer data provide an acceptable means of assessing peak accelerations, in particular for walking and jogging.  相似文献   

4.
ABSTRACT

The activPAL is a widely-used measure of sedentary time but few studies have evaluated its ability to estimate physical activity intensity. This study determined the accuracy of the algorithm used by the activPAL to predict metabolic equivalents (METs) from cadence and a curvilinear cadence-METs equation individualized for height. Thirty-six healthy adults (25 ± 6 years) completed a progressive walking protocol. Stepping cadence was video recorded and METs were determined via indirect calorimetry. Manually-counted cadence was input into the activPAL and curvilinear equations. The internal activPAL equation overpredicted METs at slower cadences (<120 steps/minute) but underpredicted METs at faster cadences (>120 step/minute) (proportional bias, p < .001). Conversely, the curvilinear equation exhibited neither fixed (p = .37) nor proportional bias (p = .07), and a lower absolute MET difference [0.87 ± 0.65 (range:0.0–3.2) vs. 0.56 ± 0.45 (range:0.0–2.7) METs]. The linear activPAL equation poorly estimates METs from stepping cadence but these inaccuracies may be lessened through the use of an individualized curvilinear equation.  相似文献   

5.
Abstract

The aim of this study was to compare the outputs of three commonly used uniaxial Actigraph models (Actitrainer, 7164 and GT1M) under both free-living and controlled laboratory conditions. Ten adults (mean age = 24.7±1.1 years) wore the three Actigraph models simultaneously during one of day free-living and during a progressive exercise protocol on a treadmill at speeds between 1.5 and 5.5 miles per hour (mph). During free-living the three Actigraph models produced comparable outputs in moderate, vigorous and moderate-to-vigorous physical activity (MVPA) with effect sizes typically <0.2, but lower comparability was seen in sedentary and light categories, as well as in total step counts (effect sizes often >0.30). In controlled conditions, acceptable comparability between the three models was seen at all treadmill speeds, the exception being walking at 1.5 mph (mean effect size = 0.48). It is concluded that care should be taken if different Actigraph models are to be used to measure and compare light physical activity, step counts and walking at very low speeds. However, using any of these three different Actigraph models to measure and compare levels of MVPA in free-living adults seems appropriate.  相似文献   

6.
The purpose of this study was to compare the accuracy of commercially-available physical activity devices when walking and running at various treadmill speeds using CTA 2056: Physical Activity Monitoring for Fitness Wearables: Step Counting, standard by the Consumer Technology Association (CTA). Twenty participants (10 males and 10 females) completed self-paced walking and running protocols on the treadmill for five minutes each. Eight devices (Apple iWatch series 1, Fitbit Surge, Garmin 235, Moto 360, Polar A360, Suunto Spartan Sport, Suunto Spartan Trainer, and TomTom Spark 3) were tested two at a time, one per wrist. Manual step counts were obtained from video to serve as the benchmark. The mean absolute percent error (MAPE) was calculated during walking and running. During walking, three devices: Fitbit Surge (11.20%), Suunto Sport (22.93%), and TomTom (10.11%) and during running, one device, Polar (10.66%), exceeded the CTA suggestion of a MAPE < 10%. The Moto 360 had the lowest MAPE of all devices for both walking and running. The devices tested had higher step accuracy with running than walking, except for the Polar. Overall, the Apple iWatch series 1, Moto 360, Garmin, and Suunto Spartan Trainer met the CTA standard for both walking and running.  相似文献   

7.
Abstract

The ActiGraph activity monitors have developed and newer versions of the ActiGraph accelerometers (GT1M, GT3X and GT3X +) are now available, including changes in hardware and software compared to the old version (AM7164). This is problematic as most of the validation and calibration work includes the AM7164. The aims of the study were to validate the ActiGraph GT1M during level and graded walking and to assess the potential underestimation of physical activity during cycling. Data were obtained from 20 participants during treadmill walking and ergometer cycling. Energy expenditure was measured via indirect calorimetry and used as the criterion method. Activity counts were highly correlated with energy expenditure during level walking (R2 = 0.82) and graded walking at 5% and 8% (R2 = 0.82 and R2 = 0.67, respectively). There was no linear relationship between activity counts and energy expenditure during cycling. The average activity counts for all data points during cycling was 1,157 counts per minute (CPM) (SD = 974), and mean energy expenditure was 5.0 metabolic equivalents. The GT1M is a valid tool for assessing walking across a wide range of speeds and gradients. However, there is no relationship between activity counts and energy expenditure during cycling and physical activity is underestimated by ≈73% during cycling compared to walking.  相似文献   

8.
Activity monitors are frequently used to assess activity in many settings. But as technology advances, so do the mechanisms used to estimate activity causing a continuous need to validate newly developed monitors. The purpose of this study was to examine the step count validity of the Yamax Digiwalker SW-701 pedometer (YX), Omron HJ-720 T pedometer (OP), Polar Active accelerometer (PAC) and Actigraph gt3x+ accelerometer (AG) under controlled and free-living conditions. Participants completed five stages of treadmill walking (n = 43) and a subset of these completed a 3-day free-living wear period (n = 37). Manually counted (MC) steps provided a criterion measure for treadmill walking, whereas the comparative measure during free-living was the YX. During treadmill walking, the OP was the most accurate monitor across all speeds (±1.1% of MC steps), while the PAC underestimated steps by 6.7–16.0% per stage. During free-living, the OP and AG counted 97.5% and 98.5% of YX steps, respectively. The PAC overestimated steps by 44.0%, or 5,265 steps per day. The Omron pedometer seems to provide the most reliable and valid estimate of steps taken, as it was the best performer under lab-based conditions and provided comparable results to the YX in free-living. Future studies should consider these monitors in additional populations and settings.  相似文献   

9.
ABSTRACT

During 20 m shuttle tests, obese adolescents may have difficulty achieving maximum cardiorespiratory performance due to the presence of braking-relaunch phases (BRP). Nineteen obese adolescents aged 15.2 ± 1.5 years (body mass index [BMI] = 39.7 ± 5.9 kg.m?2) performed three graded walking exercises on a 50 m track at speeds between 3 and 6 km/h: a continuous-straight-line protocol (C), a continuous protocol that required turning back every 30 sec (C-BRP) and an intermittent protocol that consisted of successively walking then resting for 15 sec (15–15). Oxygen uptake (VO2), aerobic cost of walking (Cw), ventilation (VE) and rating of perceived exertion (RPE) were measured at each stage during the protocols. During C-BRP, the responses were not significantly higher compared with C (p > 0.30). During 15–15, the VO2, Cw and VE were ~ 15 to 25% lower than during C beginning at 4 km/h (p < 0.05). In obese adolescents, the respiratory impact of sudden directional changes during the 20 m shuttle-type test appeared to be minor at walking speeds. During the 15–15 test, the intensity increases more progressively, and this design may encourage obese adolescents to walk further than during a continuous test.  相似文献   

10.
Abstract

The capturing of movements by means of wearable sensors has become increasingly popular in order to obtain sport performance measures during training or competition. The purpose of the current study was to investigate the feasibility of using body worn accelerometers to identify previous highlighted performance related biomechanical changes in terms of substantial differences across skill levels and skating phases. Twenty-two ice hockey players of different caliber were equipped with two 3D accelerometers, located on the skate and the waist, as they performed 30 m forward skating sprints on an ice rink. Two measures of the temporal stride characteristics (contact time and stride time) and one measure of the propulsive power (stride propulsion) of a skating stride were calculated and checked for discriminating effects across (i) skill levels and (ii) sprint phases as well as for their (iii) strength of association with the sprint performance (total sprint time). High caliber players showed an increased stride propulsion (+22%, P?<?0.05) and shorter contact time (?5%, P?<?0.05). All three analysed variables highlighted substantial biomechanical differences between the accelerative and constant velocity phases (P?<?0.05). Stride propulsion of acceleration strides primarily correlated to total sprint time (r?=??0.57, P?<?0.05). The results demonstrate the potential of accelerometers to assess skating technique elements such as contact time or elements characterizing the propulsive power such as center of mass acceleration, to gauge skating performance. Thus, the findings of this study might contribute to establishing wearable sensors for in-field ice hockey skating performance analysis.  相似文献   

11.
ABSTRACT

A means of quantifying continuous, free-living energy expenditure (EE) would advance the study of bioenergetics. The aim of this study was to apply a non-linear, machine learning algorithm (random forest) to predict minute level EE for a range of activities using acceleration, physiological signals (e.g., heart rate, body temperature, galvanic skin response), and participant characteristics (e.g., sex, age, height, weight, body composition) collected from wearable devices (Fitbit charge 2, Polar H7, SenseWear Armband Mini and Actigraph GT3-x) as potential inputs. By utilising a leave-one-out cross-validation approach in 59 subjects, we investigated the predictive accuracy in sedentary, ambulatory, household, and cycling activities compared to indirect calorimetry (Vyntus CPX). Over all activities, correlations of at least r = 0.85 were achieved by the models. Root mean squared error ranged from 1 to 1.37 METs and all overall models were statistically equivalent to the criterion measure. Significantly lower error was observed for Actigraph and Sensewear models, when compared to the manufacturer provided estimates of the Sensewear Armband (p < 0.05). A high degree of accuracy in EE estimation was achieved by applying non-linear models to wearable devices which may offer a means to capture the energy cost of free-living activities.  相似文献   

12.
The purpose of this investigation was to examine the validity of energy expenditure (EE), steps, and heart rate measured with the Apple Watch 1 and Fitbit Charge HR. Thirty-nine healthy adults wore the two monitors while completing a semi-structured activity protocol consisting of 20 minutes of sedentary activity, 25 minutes of aerobic exercise, and 25 minutes of light intensity physical activity. Criterion measures were obtained from an Oxycon Mobile for EE, a pedometer for steps, and a Polar heart rate strap worn on the chest for heart rate. For estimating whole-trial EE, the mean absolute percent error (MAPE) from Fitbit Charge HR (32.9%) was more than twice that of Apple Watch 1 (15.2%). This trend was consistent for the individual conditions. Both monitors accurately assessed steps during aerobic activity (MAPEApple: 6.2%; MAPEFitbit: 9.4%) but overestimated steps in light physical activity. For heart rate, Fitbit Charge HR produced its smallest MAPE in sedentary behaviors (7.2%), followed by aerobic exercise (8.4%), and light activity (10.1%). The Apple Watch 1 had stronger validity than the Fitbit Charge HR for assessing overall EE and steps during aerobic exercise. The Fitbit Charge HR provided heart rate estimates that were statistically equivalent to Polar monitor.  相似文献   

13.
Abstract

Race walking is an endurance event which also requires great technical ability, particularly with respect to its two distinguishing rules. The 50 km race walk is the longest event in the athletics programme at the Olympic Games. The aims of this observational study were to identify the important kinematic variables in elite men's 50 km race walking, and to measure variation in those variables at different distances. Thirty men were analysed from video data recorded during a World Race Walking Cup competition. Video data were also recorded at four distances during the European Cup Race Walking and 12 men analysed from these data. Two camcorders (50 Hz) recorded at each race for 3D analysis. The results of this study showed that walking speed was associated with both step length (r=0.54,P=0.002) and cadence (r=0.58,P=0.001). While placing the foot further ahead of the body at heel strike was associated with greater step lengths (r=0.45,P=0.013), it was also negatively associated with cadence (r= ?0.62,P<0.001). In the World Cup, knee angles ranged between 175 and 186° at initial contact and between 180 and 195° at midstance. During the European Cup, walking speed decreased significantly (F=9.35,P=0.002), mostly due to a decrease in step length between 38.5 and 48.5 km (t=8.59,P=0.014). From this study, it would appear that the key areas a 50 km race walker must develop and coordinate are step length and cadence, although it is also important to ensure legal walking technique is maintained with the onset of fatigue.  相似文献   

14.
Abstract

The aim of this study was to evaluate the utility of the RT3 accelerometer in young children, compare its accuracy with heart rate monitoring, and develop an equation to predict energy expenditure from RT3 output. Forty-two volunteers (mean age 12.2 years, s = 1.1) exercised at two horizontal and graded walking speeds (4 and 6 km · h?1, 0% grade and 6% grade), and one horizontal running speed (8 km · h?1, 0% grade), on a treadmill. Energy expenditure and oxygen consumption ([Vdot]O2) served as the criterion measures. Comparison of RT3 estimates (counts and energy expenditure) demonstrated significant differences at 4, 6, and 8 km · h?1 on level ground (P < 0.01), while no significant differences were noted between horizontal and graded walking at 4 and 6 km · h?1. Correlation and regression analyses indicated no advantage of vector magnitude over the vertical plane (X) alone. A strong relationship between RT3 estimates and indirect calorimetry across all speeds was obtained (r = 0.633–0.850, P < 0.01). A child-specific prediction equation (adjusted R 2 = 0.753) was derived and cross-validated that offered a valid energy expenditure estimate for walking/running activities. Despite recognized limitations, the RT3 may be a useful tool for the assessment of children's physical activity during walking and running.  相似文献   

15.
Abstract

Three anthropometric and eight physical performance measures selected by the author were related by correlational methods to the performance of 87 secondary school boys in the running hop, step, and jump. All variables showed a significant relationship with the criterion beyond the .05 level of confidence. The criterion could be employed as a measure of motor ability since three of the highest single-variable correlations with the criterion were measures that are known predictors of motor ability: the running broad jump (r = .859), 50-yd. dash (r = .815), and standing broad jump (r = .778). Three selected combinations of measures yielded multiple correlations with the criterion which were significant beyond the .01 level of confidence. A regression equation developed from the optimal set of variables that was considered to be feasible for administration in school systems consisted of two items from the Youth Fitness Test Manual: the standing broad jump and the 50-yd. dash.  相似文献   

16.
Abstract

Inertial sensors may provide the opportunity for broader and more cost effective gait analysis; however some questions remain over their potential use in this capacity. The aim of the study was to determine whether an inertial sensor could discriminate between normal walking, fast walking, and running. A single group crossover design was used to compare acceleration profiles between three gait conditions: normal walking, fast walking, and running. An inertial sensor was placed on the sacrum of 12 participants (6 male, 6 female) who performed 3 trials of each gait condition on both overground and treadmill settings. A significant difference (P < 0.001) in the occurrence of heel strike in the gait cycle was found between running and both walking conditions. No differences were seen between overground and treadmill in any condition or variable. The results indicate that a single sacral mounted inertial sensor can differentiate running from normal walking and fast walking using temporal gait event measures. This study indicates that inertial sensors can differentiate walking from running gait in healthy individuals which may have potential for application in the quantification of physical activity in the health and exercise industry.  相似文献   

17.
The aim of this study was to investigate the effect of cadence on volume load (VLoad) and muscle activity during agonist –antagonist paired sets (APS) in the lower body. Twelve trained men (24.0 ± 3.3 years; 78.3 ± 9.7 kg; 1.77 ± 0.58 m) volunteered to participate in this study. After the 10 maximum repetition test for leg extension and seated leg curl, participants performed three experimental protocols: first protocol (traditional)—three sets of only leg extension (60 bpm); second protocol (fast cadence)—three sets of leg extension, with each set preceded by one set on the seated leg curl with fast cadence (90 bpm); third protocol (slow cadence)—similar to the second, but seated leg curl with slow cadence (40 bpm). The total number of repetitions, VLoad and the electromyography activity for the vastus lateralis, vastus medialis and rectus femoris muscles were recorded. The VLoad was higher during APS than the traditional method, but the cadence (fast or slow) of antagonist exercise did not influence VLoad. Muscle activity of vastus lateralis was higher during traditional protocol; on the other hand, rectus femoris showed higher activity on APS fast cadence protocol, indicating that APS has a different influence on quadriceps components.  相似文献   

18.
Lower extremity joint loading during walking is strongly affected by the steepness of the slope and might cause pain and injuries in lower extremity joint structures. One feasible measure to reduce joint loading is the reduction of walking speed. Positive effects have been shown for level walking, but not for graded walking or hiking conditions. The aim of the study was to quantify the effect of walking speed (separated into the two components, step length and cadence) on the joint power of the hip, knee and ankle and to determine the knee joint forces in uphill and downhill walking. Ten participants walked up and down a ramp with step lengths of 0.46, 0.575 and 0.69 m and cadences of 80, 100 and 120 steps per minute. The ramp was equipped with a force platform and the locomotion was filmed with a 60 Hz video camera. Loading of the lower extremity joints was determined using inverse dynamics. A two-dimensional knee model was used to calculate forces in the knee structures during the stance phase. Walking speed affected lower extremity joint loading substantially and significantly. Change of step length caused much greater loading changes for all joints compared with change of cadence; the effects were more distinct in downhill than in uphill walking. The results indicate that lower extremity joint loading can be effectively controlled by varying step length and cadence during graded uphill and downhill walking. Hikers can avoid or reduce pain and injuries by reducing walking speed, particularly in downhill walking.  相似文献   

19.
Physical activity benefits for disease prevention are well-established. Smartphones offer a convenient platform for community-based step count estimation to monitor and encourage physical activity. Accuracy is dependent on hardware–software platforms, creating a recurring challenge for validation, but the Apple iPhone® M7 motion co-processor provides a standardised method that helps address this issue. Validity of the M7 to record step count for level-ground, able-bodied walking at three self-selected speeds, and agreement with the StepWatchTM was assessed. Steps were measured concurrently with the iPhone® (custom application to extract step count), StepWatchTM and manual count. Agreement between iPhone® and manual/StepWatchTM count was estimated through Pearson correlation and Bland-Altman analyses. Data from 20 participants suggested that iPhone® step count correlations with manual and StepWatchTM were strong for customary (1.3 ± 0.1 m/s) and fast (1.8 ± 0.2 m/s) speeds, but weak for the slow (1.0 ± 0.1 m/s) speed. Mean absolute error (manual–iPhone®) was 21%, 8% and 4% for the slow, customary and fast speeds, respectively. The M7 accurately records step count during customary and fast walking speeds, but is prone to considerable inaccuracies at slow speeds which has important implications for certain patient groups. The iPhone® may be a suitable alternative to the StepWatchTM for only faster walking speeds.  相似文献   

20.
This study establishes tri-axial activity count (AC) cut-points for the GT3X+ accelerometer to classify physical activity intensity in overweight and obese adults. Further, we examined the accuracy of established and novel energy expenditure (EE) prediction equations based on AC and other metrics. Part 1: Twenty overweight or obese adults completed a 30 minute incremental treadmill walking protocol. Heart rate (HR), EE, and AC were measured using the GT3X+ accelerometer. Part 2: Ten overweight and obese adults conducted a self-paced external walk during which EE, AC, and HR were measured. Established equations (Freedson et al., 1998; Sasaki et al., 2011) overestimated EE by 40% and 31%, respectively (< .01). Novel gender-specific prediction equations provided good estimates of EE during treadmill and outdoor walking (standard error of the estimate = .91 and .65, respectively). We propose new cut-points and prediction equations to estimate EE using the GT3X+ tri-axial accelerometer in overweight and obese adults.  相似文献   