首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Near-infrared spectroscopy is currently used to assess changes in the oxygen saturation of the muscle during exercise. The primary purpose of this study was to assess the reliability of near-infrared spectroscopy in determining muscle oxygen saturation (StO2) in the vastus lateralis during cycling and the gastrocnemius during running for exercise intensities at lactate threshold and maximal effort. Test-retest reliability was determined from an intraclass correlation coefficient obtained from a one-way analysis of variance. Reliability of muscle StO2 for the gastrocnemius at lactate threshold was R = .87, and R = .88 at maximal effort. Reliability of muscle StO2 for the vastus lateralis at lactate threshold was R = .94 and R = .99 at maximal effort.  相似文献   

2.
Abstract

The objective of this study was to determine whether sprint performance is related to the mechanical (elongation – force relationship of the tendon and aponeurosis, muscle strength) and morphological (fascicle length, pennation angle, muscle thickness) properties of the quadriceps femoris and triceps surae muscle – tendon units. Two groups of sprinters (slow, n = 11; fast, n = 17) performed maximal isometric knee extension and plantar flexion contractions on a dynamometer at 11 different muscle – tendon unit lengths. Elongation of the tendon and aponeurosis of the gastrocnemius medialis and the vastus lateralis was measured using ultrasonography. We observed no significant differences in maximal joint moments at the ankle and knee joints or morphological properties of the gastrocnemius medialis and vastus lateralis between groups (P > 0.05). The fast group exhibited greater elongation of the vastus lateralis tendon and aponeurosis at a given tendon force, and greater maximal elongation of the vastus lateralis tendon and aponeurosis during maximum voluntary contraction (P < 0.05). Furthermore, maximal elongation of the vastus lateralis tendon and aponeurosis showed a significant correlation with 100-m sprint times (r = ?0.567, P = 0.003). For the elongation – force relationship at the gastrocnemius medialis tendon and aponeurosis, the two groups recorded similar values. It is suggested that the greater elongation of the vastus lateralis tendon and aponeurosis of the fast group benefits energy storage and return as well as the shortening velocity of the muscle – tendon unit.  相似文献   

3.
Abstract

The objective of this study was to investigate the effects of wearing compression socks (CS) on performance indicators and physiological responses during prolonged trail running. Eleven trained runners completed a 15.6 km trail run at a competition intensity whilst wearing or not wearing CS. Counter movement jump, maximal voluntary contraction and the oxygenation profile of vastus lateralis muscle using near-infrared spectroscopy (NIRS) method were measured before and following exercise. Run time, heart rate (HR), blood lactate concentration and ratings of perceived exertion were evaluated during the CS and non-CS sessions. No significant difference in any dependent variables was observed during the run sessions. Run times were 5681.1±503.5 and 5696.7±530.7 s for the non-CS and CS conditions, respectively. The relative intensity during CS and non-CS runs corresponded to a range of 90.5–91.5% HRmax. Although NIRS measurements such as muscle oxygen uptake and muscle blood flow significantly increased following exercise (+57.7% and + 42.6%,+59.2% and + 32.4%, respectively for the CS and non-CS sessions, P<0.05), there was no difference between the run conditions. The findings suggest that competitive runners do not gain any practical or physiological benefits from wearing CS during prolonged off-road running.  相似文献   

4.
The objective of this study was to determine whether sprint performance is related to the mechanical (elongation - force relationship of the tendon and aponeurosis, muscle strength) and morphological (fascicle length, pennation angle, muscle thickness) properties of the quadriceps femoris and triceps surae muscle - tendon units. Two groups of sprinters (slow, n = 11; fast, n = 17) performed maximal isometric knee extension and plantar flexion contractions on a dynamometer at 11 different muscle - tendon unit lengths. Elongation of the tendon and aponeurosis of the gastrocnemius medialis and the vastus lateralis was measured using ultrasonography. We observed no significant differences in maximal joint moments at the ankle and knee joints or morphological properties of the gastrocnemius medialis and vastus lateralis between groups (P > 0.05). The fast group exhibited greater elongation of the vastus lateralis tendon and aponeurosis at a given tendon force, and greater maximal elongation of the vastus lateralis tendon and aponeurosis during maximum voluntary contraction (P < 0.05). Furthermore, maximal elongation of the vastus lateralis tendon and aponeurosis showed a significant correlation with 100-m sprint times (r = -0.567, P = 0.003). For the elongation - force relationship at the gastrocnemius medialis tendon and aponeurosis, the two groups recorded similar values. It is suggested that the greater elongation of the vastus lateralis tendon and aponeurosis of the fast group benefits energy storage and return as well as the shortening velocity of the muscle - tendon unit.  相似文献   

5.
This study was conducted to determine the effects of inspiratory muscle training (IMT) on respiratory and peripheral muscles oxygenation during a maximal exercise tolerance test and on repeated-sprint ability (RSA) performance in professional women football players. Eighteen athletes were randomly assigned to one of the following groups: SHAM (n = 8) or IMT (n = 10). After a maximal incremental exercise test, all participants performed (on a different day) a time-to-exhaustion (Tlim) test. Peripheral and respiratory muscles oxygenation by near-infrared spectroscopy, breath-by-breath ventilatory and metabolic variables, and blood lactate concentration were measured. The RSA test was performed on a grass field. After a 6 week intervention, all athletes were reevaluated. Both groups showed increases in inspiratory muscles strength, exercise tolerance and RSA performance, however only the IMT group presented lower deoxyhemoglobin and total hemoglobin blood concentrations on intercostal muscles concomitantly to an increased oxyhemoglobin and total hemoglobin blood concentrations on vastus lateralis muscle during Tlim. In conclusion, these results may indicate the potential role of IMT to attenuate inspiratory muscles metaboreflex and consequently improve oxygen and blood supply to limb muscles during high-intensity exercise, with a potential impact on inspiratory muscle strength, exercise tolerance and sprints performance in professional women football players.  相似文献   

6.
This study examined the effect of hypoxia on growth hormone (GH) release during an acute bout of high-intensity, low-volume resistance exercise. Using a single-blinded, randomised crossover design, 16 resistance-trained males completed two resistance exercise sessions in normobaric hypoxia (HYP; inspiratory oxygen fraction, (FiO2) 0.12, arterial oxygen saturation (SpO2) 82?±?2%) and normoxia (NOR; FiO2 0.21, SpO2 98?±?0%). Each session consisted of five sets of three repetitions of 45° leg press and bench press at 85% of one repetition maximum. Heart rate, SpO2, and electromyographic activity (EMG) of the vastus lateralis muscle were measured throughout the protocol. Serum lactate and GH levels were determined pre-exposure, and at 5, 15, 30 and 60?min post-exercise. Differences in mean and integrated EMG between HYP and NOR treatments were unclear. However, there was an important increase in the peak levels and area under the curve of both lactate (HYP 5.8?±?1.8 v NOR 3.9?±?1.1?mmol.L?1 and HYP 138.7?±?33.1 v NOR 105.8?±?20.8?min.mmol.L?1) and GH (HYP 4.4?±?3.1 v NOR 2.1?±?2.5?ng.mL?1 and HYP 117.7?±?86.9 v NOR 72.9?±?85.3?min.ng.mL?1) in response to HYP. These results suggest that performing high-intensity resistance exercise in a hypoxic environment may provide a beneficial endocrine response without compromising the neuromuscular activation required for maximal strength development.  相似文献   

7.
Abstract

In this study, we wished to determine whether the observed reduction in quadriceps muscle oxygen availability, reported during repetitive bouts of isometric exercise in simulated sailing efforts (i.e. hiking), is because of restricted muscle blood flow. Six national-squad Laser sailors initially performed three successive 3-min hiking bouts followed by three successive 3-min cycling tests sustained at constant intensities reproducing the cardiac output recorded during each of the three hiking bouts. The blood flow index (BFI) was determined from assessment of the vastus lateralis using near-infrared spectroscopy in association with the light-absorbing tracer indocyanine green dye, while cardiac output was determined from impedance cardiography. At equivalent cardiac outputs (ranging from 10.3±0.5 to 14.8±0.86 L · min?1), the increase from baseline in vastus lateralis BFI across the three hiking bouts (from 1.1±0.2 to 3.1±0.6 nM · s?1) was lower (P = 0.036) than that seen during the three cycling bouts (from 1.1±0.2 to 7.2±1.4 nM · s?1) (Cohen's d: 3.80 nM · s?1), whereas the increase from baseline in deoxygenated haemoglobin (by ~17.0±2.9 μM) (an index of tissue oxygen extraction) was greater (P = 0.006) during hiking than cycling (by ~5.3±2.7 μM) (Cohen's d: 4.17 μM). The results suggest that reduced vastus lateralis muscle oxygen availability during hiking arises from restricted muscle blood flow in the isometrically acting quadriceps muscles.  相似文献   

8.
Electromyographic (EMG) activity of the leg muscles and the ground reaction forces were recorded in 17 elite male middle-distance runners, who performed isometric maximal voluntary contractions (MVC) as well as running at different speeds. Electromyograms were recorded from the gluteus maximus, vastus lateralis, biceps femoris, gastrocnemius and tibialis anterior. The results indicated that the averaged EMG (aEMG) activities of all the muscles studied increased (P?<?0.05) with increasing running speed, especially in the pre-contact and braking phases. At higher speeds, the aEMG activities of the gastrocnemius, vastus lateralis, biceps femoris and gluteus maximus exceeded 100% MVC in these same phases. These results suggest that maximal voluntary contractions cannot be used as an indicator of the full activation potential of human skeletal muscle. Furthermore, the present results suggest that increased pre-contact EMG potentiates the functional role of stretch reflexes, which subsequently increases tendomuscular stiffness and enhances force production in the braking and/or propulsive phases in running. Furthermore, a more powerful force production in the optimal direction for increasing running speed effectively requires increased EMG activity of the two-joint muscles (biceps femoris, rectus femoris and gastrocnemius) during the entire running cycle.  相似文献   

9.

Purpose: This study compared the relative peak torque and normalized electromyographic (EMG) mean frequency (MNF) responses during fatiguing isokinetic muscle actions for men versus women. Method: Twenty men (M age ± SD = 22 ± 2 years) and 20 women (M age ± SD = 22 ± 1 years) performed 50 maximal concentric isokinetic muscle actions of the leg extensors at a velocity of 180°/s while surface EMG signals were detected from the vastus lateralis, rectus femoris, and vastus medialis. The dependent variables were initial, final, and average peak torque; percent decline; the estimated percentage of fast-twitch fibers for the vastus lateralis; and the linear slope coefficients and y-intercepts for normalized EMG MNF versus repetition number. The data were analyzed with independent-samples t tests and 2-way mixed-factorial analyses of variance. Results: The mean initial, final, and average peak torque values for men were greater than those for women. There were no mean differences for percent decline and the estimated percentage of fast-twitch fibers for the vastus lateralis. There were also no sex differences for the linear slope coefficients, but there were differences among the muscles (vastus medialis>vastus lateralis>rectus femoris). The mean y-intercept for the vastus lateralis for men was greater than that for women. Conclusions: Men demonstrated greater peak torque values than those for women, but the declines in peak torque and normalized EMG MNF were similar between the sexes. The vastus medialis was more fatigue-resistant than both the vastus lateralis and rectus femoris.  相似文献   

10.
Abstract

The aim of this study was to examine the time-course of and the relationships between muscle oxygenation, blood volume and myoelectrical manifestations during isometric exercise in children. Twelve healthy children aged 12.5 ± 1.2 years (mean ± s) performed an isometric knee extension at 50% of their maximal voluntary contraction (MVC) until exhaustion to assess endurance time (limit time, T lim). Changes in muscle oxygenation and blood volume were assessed by near infrared spectroscopy (NIRS). The root mean square (RMS) amplitude and the mean power frequency (MPF) from electromyogram (EMG) signals were obtained, as NIRS parameters, from the vastus lateralis. Mean T lim was 117 ± 34 s. The muscle oxygenation and blood volume curves decreased immediately at the beginning of exercise. Maximal deoxygenation occurred at 50% T lim, and fell by 76.9% from the resting value. Similarly, minimal blood volume was observed at 50% T lim; it reached a plateau that lasted until the end of exercise. The kinetics of the MPF and RMS curves were inversely related to time. At the last set of exercises (after 75% T lim), a steeper RMS curve and an abrupt decrease in the MPF curve were observed. Significant correlations (r) between muscle oxygenation, blood volume, root mean square amplitude and mean power frequency were observed, which ranged from 0.72 to 0.99. These findings suggest that the fatigue resulting from sustained isometric exercise is related to a decrease in oxygenation and blood volume.  相似文献   

11.
The purpose of the current study was to examine the effect of 6 weeks of whole body vibration training (WBVT) on body composition, muscle activity of the gastrocnemius and vastus lateralis, gastrocnemius muscle architecture (static and dynamic) and ground reaction forces (performance jump) during the take-off phase of a countermovement jump in young healthy adult males. A total of 33 men (23.31 ± 5.62 years) were randomly assigned to a whole body vibration group (experimental group, EGWBVT: n = 17; 22.11 ± 4.97 years) or a control group (CG: n = 16; 24.5 ± 6.27 years). The total duration of the intervention phase (WBVT) was 6 weeks with a frequency of 3 sessions per week. Statistically significant differences were observed (P ≤ 0.05) between pre- and post-test in the power peak (Δ 1.91 W · kg?1; P = 0.001), take-off velocity (0.1 cm · s?1; P = 0.002) and jump height (Δ 0.4 cm; P = 0.002) for EGWBVT. There were no statistically significant differences in any of the body composition and muscle architecture variables. Moreover, no significant differences were found between EGWBVT and CG nor changes in muscle activity during take-off phase of the gastrocnemius and vastus lateralis pre- versus post-training. This study suggests that a 6-week WBVT programme with increasing intensity improves jump performance but does not alter muscle activity nor muscle architecture in healthy young men.  相似文献   

12.
The aim of this study was to describe and compare the EMG patterns of select lower limb muscles throughout the golf swing, performed with three different clubs, in non-elite middle-aged players. Fourteen golfers performed eight swings each using, in random order, a pitching wedge, 7-iron and 4-iron. Surface electromyography (EMG) was recorded bilaterally from lower limb muscles: tibialis anterior, peroneus longus, gastrocnemius medialis, gastrocnemius lateralis, biceps femoris, semitendinosus, gluteus maximus, vastus medialis, rectus femoris and vastus lateralis. Three-dimensional high-speed video analysis was used to determine the golf swing phases. Results showed that, in average handicap golfers, the highest muscle activation levels occurred during the Forward Swing Phase, with the right semitendinosus and the right biceps femoris muscles producing the highest mean activation levels relative to maximal electromyography (70–76% and 68–73% EMGMAX, respectively). Significant differences between the pitching wedge and the 4-iron club were found in the activation level of the left semitendinosus, right tibialis anterior, right peroneus longus, right vastus medialis, right rectus femuris and right gastrocnemius muscles. The lower limb muscles showed, in most cases and phases, higher mean values of activation on electromyography when golfers performed shots with a 4-iron club.  相似文献   

13.
Rowers need to combine high sprint and endurance capacities. Muscle morphology largely explains muscle power generating capacity, however, little is known on how muscle morphology relates to rowing performance measures. The aim was to determine how muscle morphology of the vastus lateralis relates to rowing ergometer performance, sprint and endurance capacity of Olympic rowers. Eighteen rowers (12♂, 6♀, who competed at 2016 Olympics) performed an incremental rowing test to obtain maximal oxygen consumption, reflecting endurance capacity. Sprint capacity was assessed by Wingate cycling peak power. M. vastus lateralis morphology (volume, physiological cross-sectional area, fascicle length and pennation angle) was derived from 3-dimensional ultrasound imaging. Thirteen rowers (7♂, 6♀) completed a 2000-m rowing ergometer time trial. Muscle volume largely explained variance in 2000-m rowing performance (R2 = 0.85), maximal oxygen consumption (R2 = 0.65), and Wingate peak power (R2 = 0.82). When normalized for differences in body size, maximal oxygen consumption and Wingate peak power were negatively related in males (r = ?0.94). Fascicle length, not physiological cross-sectional area, attributed to normalized peak power. In conclusion, vastus lateralis volume largely explains variance in rowing ergometer performance, sprint and endurance capacity. For a high normalized sprint capacity, athletes may benefit from long fascicles rather than a large physiological cross-sectional area.  相似文献   

14.
A rugby scrum’s front row must act uniformly to transfer maximal horizontal force and improve performance. This study investigated the muscle activation patterns of lower extremity muscles in front row forwards during live and machine scrums at professional and amateur levels. Electromyography was collected bilaterally on vastus lateralis, rectus femoris and gastrocnemius muscles of 75 male rugby prop players during live and machine scrums. ANOVAs compared muscle reaction time, rate of change in muscle amplitude and muscle amplitude between groups and conditions. Cross-correlation analysis explored muscle synchronicity. There were significantly greater rates of change in each muscle amplitude in professional players than amateur players. Additionally, there was significantly quicker muscle reaction time in all muscles, and greater amplitude in vastus lateralis and gastrocnemius, during the live scrum vs. machine condition. The professional props produced more synchronised muscle activation than amateur players and all players produced more synchronised muscle activation against the scrum machine vs. live scrummage. The results indicate a higher skill proficiency and muscle synchronicity in professional players. While scrum machine training is ideally suited for functional muscle strengthening during practice, to truly simulate the requirements of the scrum, training should incorporate the live situation as much as possible.  相似文献   

15.
Changes in muscle activity with increasing running speed   总被引:3,自引:2,他引:1  
Electromyographic (EMG) activity of the leg muscles and the ground reaction forces were recorded in 17 elite male middle-distance runners, who performed isometric maximal voluntary contractions (MVC) as well as running at different speeds. Electromyograms were recorded from the gluteus maximus, vastus lateralis, biceps femoris, gastrocnemius and tibialis anterior. The results indicated that the averaged EMG (aEMG) activities of all the muscles studied increased (P < 0.05) with increasing running speed, especially in the pre-contact and braking phases. At higher speeds, the aEMG activities of the gastrocnemius, vastus lateralis, biceps femoris and gluteus maximus exceeded 100% MVC in these same phases. These results suggest that maximal voluntary contractions cannot be used as an indicator of the full activation potential of human skeletal muscle. Furthermore, the present results suggest that increased pre-contact EMG potentiates the functional role of stretch reflexes, which subsequently increases tendomuscular stiffness and enhances force production in the braking and/or propulsive phases in running. Furthermore, a more powerful force production in the optimal direction for increasing running speed effectively requires increased EMG activity of the two-joint muscles (biceps femoris, rectus femoris and gastrocnemius) during the entire running cycle.  相似文献   

16.
The purpose of this study was to investigate the use of a single 3-min all-out maximal effort to estimate anaerobic capacity (AC) through the lactate and excess post-exercise oxygen consumption (EPOC) response methods (AC[La?]+EPOCfast) on a cycle ergometer. Eleven physically active men (age?=?28.1?±?4.0?yrs, height?=?175.1?±?4.2?cm, body mass?=?74.8?±?11.9?kg and ?O2max?=?40.7?±?7.3?mL?kg?1?min?1), participated in the study and performed: i) five submaximal efforts, ii) a supramaximal effort at 115% of intensity of ?O2max, and iii) a 3-min all-out maximal effort. Anaerobic capacity was estimated using the supramaximal effort through conventional maximal accumulated oxygen deficit (MAOD) and also through the sum of oxygen equivalents from the glycolytic (fast component of excess post-exercise oxygen consumption) and phosphagen pathways (blood lactate accumulation) (AC[La?]+EPOCfast), while during the 3-min all-out maximal effort the anaerobic capacity was estimated using the AC[La?]+EPOCfast procedure. There were no significant differences between the three methods (p?>?0.05). Additionally, the anaerobic capacity estimated during the 3-min all-out effort was significantly correlated with the MAOD (r?=?0.74; p?=?0.009) and AC[La?]+EPOCfast methods (r?=?0.65; p?=?0.029). Therefore, it is possible to conclude that the 3-min all-out effort is valid to estimate anaerobic capacity in physically active men during a single cycle ergometer effort.  相似文献   

17.
Introduction: The Moxy is a novel, cutaneously placed muscle oxygen monitor which claims to measure local oxygen saturation (SmO2) and total haemoglobin (THb) using near-infrared spectroscopy. If shown to be reliable, its data storage and telemetric capability will be useful for assessing localised O2 usage during field-based exercise. This study investigated the reliability of the Moxy during cycling and assessed the correlations between its measurements, whole-body O2 consumption (VO2) and heart rate (HR). Methods: Ten highly trained cyclists performed an incremental, step-wise cycling protocol on two occasions while wearing the Moxy. SmO2, THb, VO2 and HR were recorded in the final minute of each five-minute stage. Data were analysed using Spearman’s Order-Rank Coefficient (SROC), Intraclass Correlation (ICC), and Coefficient of Variance (COV). Significance was set at p?≤?.05. Results: SmO2 showed a ‘strong’ or ‘very large’ correlation between trials (SROC: r?=?0.842–0.993, ICC: r?=?0.773–0.992, p?≤?.01) and was moderately correlated with VO2 and HR (r?=??0.71–0.73, p?≤?.01). SmO2 showed a moderate to high reliability at low intensities, but this decreased as relative exercise intensity increased. THb showed poor correlations between tests and with the other measured variables, but was highly reliable at all power outputs. Conclusions: The Moxy is a reliable device to measure SmO2 at low to moderate intensities, but at higher intensities, greater variation in measurements occurs, likely due to tissue ischaemia or increased movement artefacts due to more frequent muscular contractions. THb has low variation during exercise, and does not appear to be a valid indicator of muscle oxygenation.  相似文献   

18.
ABSTRACT

This study assessed the intra-individual reliability of oxygen saturation in intercostal muscles (SmO2-m.intercostales) during an incremental maximal treadmill exercise by using portable NIRS devices in a test-retest study. Fifteen marathon runners (age, 24.9 ± 2.0 years; body mass index, 21.6 ± 2.3 kg·m?2; V?O2-peak, 63.7 ± 5.9 mL·kg?1·min?1) were tested on two separate days, with a 7-day interval between the two measurements. Oxygen consumption (V?O2) was assessed using the breath-by-breath method during the V?O2-test, while SmO2 was determined using a portable commercial device, based in the near-infrared spectroscopy (NIRS) principle. The minute ventilation (VE), respiratory rate (RR), and tidal volume (Vt) were also monitored during the cardiopulmonary exercise test. For the SmO2-m.intercostales, the intraclass correlation coefficient (ICC) at rest, first (VT1) and second ventilatory (VT2) thresholds, and maximal stages were 0.90, 0.84, 0.92, and 0.93, respectively; the confidence intervals ranged from ?10.8% – +9.5% to ?15.3% – +12.5%. The reliability was good at low intensity (rest and VT1) and excellent at high intensity (VT2 and max). The Spearman correlation test revealed (p ≤ 0.001) an inverse association of SmO2-m.intercostales with V?O2 (ρ = ?0.64), VE (ρ = ?0.73), RR (ρ = ?0.70), and Vt (ρ = ?0.63). The relationship with the ventilatory variables showed that increased breathing effort during exercise could be registered adequately using a NIRS portable device.  相似文献   

19.
In this study, we wished to determine whether the observed reduction in quadriceps muscle oxygen availability, reported during repetitive bouts of isometric exercise in simulated sailing efforts (i.e. hiking), is because of restricted muscle blood flow. Six national-squad Laser sailors initially performed three successive 3-min hiking bouts followed by three successive 3-min cycling tests sustained at constant intensities reproducing the cardiac output recorded during each of the three hiking bouts. The blood flow index (BFI) was determined from assessment of the vastus lateralis using near-infrared spectroscopy in association with the light-absorbing tracer indocyanine green dye, while cardiac output was determined from impedance cardiography. At equivalent cardiac outputs (ranging from 10.3±0.5 to 14.8±0.86 L · min(-1)), the increase from baseline in vastus lateralis BFI across the three hiking bouts (from 1.1±0.2 to 3.1±0.6 nM · s(-1)) was lower (P = 0.036) than that seen during the three cycling bouts (from 1.1±0.2 to 7.2±1.4 nM · s(-1)) (Cohen's d: 3.80 nM · s(-1)), whereas the increase from baseline in deoxygenated haemoglobin (by ~17.0±2.9 μM) (an index of tissue oxygen extraction) was greater (P = 0.006) during hiking than cycling (by ~5.3±2.7 μM) (Cohen's d: 4.17 μM). The results suggest that reduced vastus lateralis muscle oxygen availability during hiking arises from restricted muscle blood flow in the isometrically acting quadriceps muscles.  相似文献   

20.
Abstract

The purpose of this study was to examine the changes in the metabolic state of quadriceps femoris muscles using transverse relaxation time (T2), measured by muscle functional magnetic resonance (MR) imaging, after inactive or active recovery exercises with different intensities following high-intensity knee-extension exercise. Eight healthy men performed recovery sessions with four different conditions for 20 min after high-intensity knee-extension exercise on separate days. During the recovery session, the participants conducted a light cycle exercise for 20 min using a cycle (50%, 70% and 100% of the lactate threshold (LT), respectively: active recovery), and inactive recovery. The MR images of quadriceps femoris muscles were taken before the trial and after the recovery session every 30 min for 120 min. The percentage changes in T2 for the rectus femoris and vastus medialis muscles after the recovery session in 50%LT and 70%LT were significantly lower than those in either inactive recovery or 100%LT. There were no significant differences in those for vastus lateralis and vastus intermedius muscles among the four trials. The percentage changes in T2 of rectus femoris and vastus medialis muscles after the recovery session in 50%LT and 70%LT decreased to the values before the trial faster than those in either inactive recovery or 100%LT. Those of vastus lateralis and vastus intermedius muscles after the recovery session in 50%LT and 70%LT decreased to the values before the trial faster than those in 100%LT. Although the changes in T2 after active recovery exercises were not uniform in exercised muscles, the results of this study suggest that active recovery exercise with the intensities below LT are more effective to recover the metabolic state of quadriceps femoris muscles after intense exercise than with either intensity at LT or inactive recovery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号