首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We examined the role of rotation axes during an overarm throwing task. Participants performed such task and were asked to throw a ball at maximal velocity at a target. The purpose of this study was to examine whether the minimum inertia axis would be exploited during the throwing phases, a time when internal–external rotations of the shoulder are particularly important. A motion capture system was used to evaluate the performance and to compute the potential axes of rotation (minimum inertia axis, shoulder–centre of mass axis and the shoulder–elbow axis). More specifically, we investigated whether a velocity-dependent change in rotational axes can be observed in the different throwing phases and whether the control obeys the principle of minimum inertia resistance. Our results showed that the limbs’ rotational axis mainly coincides with the minimum inertia axis during the cocking phase and with the shoulder–elbow axis during the acceleration phase. Besides these rotation axes changes, the use of interaction torque is also sequence-dependent. The sequence-dependent rotation axes changes associated with the use of interaction torque during the acceleration phase could be a key factor in the production of hand velocity at ball release.  相似文献   

2.
Waiter’s serve (WS) is a specific tennis serve posture frequently observed in young players, and commonly considered as a technical error by tennis coaches. However, biomechanical impact of WS is unknown. The aims of this study were to identify the potential consequences of WS in young elite players relating to performance and injury risk, and to explain the kinematic causes of WS. Serve of 18 male junior elite players (Top 10 national French ranking, aged 12–15 years) was captured with a 20 camera, 200?Hz VICON MX motion analysis system. Depending on their serve technique, the players were divided into two groups (WS versus Normal Serve [NS]) by experienced coaches. Injury data were collected for each player during a 12-month-period following the motion capture. Normalized peak kinetic values of the dominant arm were calculated using inverse dynamics. In order to explain WS posture, upper limb kinematics were calculated during the cocking and the acceleration phases of the serve. Shoulder internal rotation torque, wrist proximal and anterior forces (P?P?P?相似文献   

3.
The aim of this study was to compare and evaluate the kinematics of baseball pitchers who participated in the 1996 XXVI Centennial Olympic Games. Two synchronized video cameras operating at 120 Hz were used to video 48 pitchers from Australia, Japan, the Netherlands, Cuba, Italy, Korea, Nicaragua and the USA. All pitchers were analysed while throwing the fastball pitch. Twenty-one kinematic parameters were measured at lead foot contact, during the arm cocking and arm acceleration phases, and at the instant of ball release. These parameters included stride length, foot angle and foot placement; shoulder abduction, shoulder horizontal adduction and shoulder external rotation; knee and elbow flexion; upper torso, shoulder internal rotation and elbow extension angular velocities; forward and lateral trunk tilt; and ball speed. A one-way analysis of variance (P ? 0.01) was used to assess kinematic differences. Shoulder horizontal adduction and shoulder external rotation at lead foot contact and ball speed at the instant of ball release were significantly different among countries. The greater shoulder horizontal abduction observed in Cuban pitchers at lead foot contact is thought to be an important factor in the generation of force throughout the arm cocking and arm acceleration phases, and may in part explain why Cuban pitchers generated the greatest ball release speed. We conclude that pitching kinematics are similar among baseball pitchers from different countries.  相似文献   

4.
Kinematic comparisons of 1996 Olympic baseball pitchers   总被引:1,自引:0,他引:1  
The aim of this study was to compare and evaluate the kinematics of baseball pitchers who participated in the 1996 XXVI Centennial Olympic Games. Two synchronized video cameras operating at 120 Hz were used to video 48 pitchers from Australia, Japan, the Netherlands, Cuba, Italy, Korea, Nicaragua and the USA. All pitchers were analysed while throwing the fastball pitch. Twenty-one kinematic parameters were measured at lead foot contact, during the arm cocking and arm acceleration phases, and at the instant of ball release. These parameters included stride length, foot angle and foot placement; shoulder abduction, shoulder horizontal adduction and shoulder external rotation; knee and elbow flexion; upper torso, shoulder internal rotation and elbow extension angular velocities; forward and lateral trunk tilt; and ball speed. A one-way analysis of variance (P < 0.01) was used to assess kinematic differences. Shoulder horizontal adduction and shoulder external rotation at lead foot contact and ball speed at the instant of ball release were significantly different among countries. The greater shoulder horizontal abduction observed in Cuban pitchers at lead foot contact is thought to be an important factor in the generation of force throughout the arm cocking and arm acceleration phases, and may in part explain why Cuban pitchers generated the greatest ball release speed. We conclude that pitching kinematics are similar among baseball pitchers from different countries.  相似文献   

5.
Baseball     
The purpose of this study was to quantify and compare kinematic, temporal, and kinetic characteristics of American and Korean professional pitchers in order to investigate differences in pitching mechanics, performance, and injury risks among two different cultures and populations of baseball pitchers. Eleven American and eight Korean healthy professional baseball pitchers threw multiple fastball pitches off an indoor throwing mound positioned at regulation distance from home plate. A Motion Analysis three‐dimensional automatic digitizing system was used to collect 200 Hz video data from four electronically synchronized cameras. Twenty kinematic, six temporal, and 11 kinetic variables were analyzed at lead foot contact, during the arm cocking and arm acceleration phases, at ball release, and during the arm deceleration phase. A radar gun was used to quantify ball velocity. At lead foot contact, the American pitchers had significantly greater horizontal abduction of the throwing shoulder, while Korean pitchers exhibited significantly greater abduction and external rotation of the throwing shoulder. During arm cocking, the American pitchers displayed significantly greater maximum shoulder external rotation and maximum pelvis angular velocity. At the instant of ball release, the American pitchers had significantly greater forward trunk tilt and ball velocity and significantly less knee flexion, which help explain why the American pitchers had 10% greater ball velocity compared to the Korean pitchers. The American pitchers had significantly greater maximum shoulder internal rotation torque and maximum elbow varus torque during arm cocking, significantly greater elbow flexion torque during arm acceleration, and significantly greater shoulder and elbow proximal forces during arm deceleration. While greater shoulder and elbow forces and torques generated in the American pitchers helped generate greater ball velocity for the American group, these greater kinetics may predispose this group to a higher risk of shoulder and elbow injuries.  相似文献   

6.
The purpose of this study was to quantify and compare kinematic, temporal, and kinetic characteristics of American and Korean professional pitchers in order to investigate differences in pitching mechanics, performance, and injury risks among two different cultures and populations of baseball pitchers. Eleven American and eight Korean healthy professional baseball pitchers threw multiple fastball pitches off an indoor throwing mound positioned at regulation distance from home plate. A Motion Analysis three-dimensional automatic digitizing system was used to collect 200 Hz video data from four electronically synchronized cameras. Twenty kinematic, six temporal, and 11 kinetic variables were analyzed at lead foot contact, during the arm cocking and arm acceleration phases, at ball release, and during the arm deceleration phase. A radar gun was used to quantify ball velocity. At lead foot contact, the American pitchers had significantly greater horizontal abduction of the throwing shoulder, while Korean pitchers exhibited significantly greater abduction and external rotation of the throwing shoulder. During arm cocking, the American pitchers displayed significantly greater maximum shoulder external rotation and maximum pelvis angular velocity. At the instant of ball release, the American pitchers had significantly greater forward trunk tilt and ball velocity and significantly less knee flexion, which help explain why the American pitchers had 10% greater ball velocity compared to the Korean pitchers. The American pitchers had significantly greater maximum shoulder internal rotation torque and maximum elbow varus torque during arm cocking, significantly greater elbow flexion torque during arm acceleration, and significantly greater shoulder and elbow proximal forces during arm deceleration. While greater shoulder and elbow forces and torques generated in the American pitchers helped generate greater ball velocity for the American group, these greater kinetics may predispose this group to a higher risk of shoulder and elbow injuries.  相似文献   

7.
Scapular dyskinesis is recognized as an abnormality in the kinetic chain; yet, there has been little research quantifying scapular motion during sport tasks. Tennis forehand drives of eight highly skilled tennis players were studied to assess the scapulothoracic kinematics and evaluate repeatability using video-based motion analysis. Scapulothoracic downward/upward rotation, posterior/anterior tilt, and internal/external rotation were computed using an acromial marker cluster. On average, the upward rotation, anterior tilt, and internal rotation varied from 1° to 26°, from 7° to 32°, and from 42° to 100°, respectively, during the tennis forehand drive. During the backswing and forward swing phases of the forehand stroke, small changes were observed for the three scapular angle values, while all angles increased rapidly during the follow-through phase. This suggests that the tennis forehand drive may contribute to scapula dyskinesis, mainly due to the great amplitude in scapulothoracic anterior tilt and internal rotation observed during the follow-through phase. Knowledge of normal scapula motion during sport tasks performed at high velocity could improve the understanding of various sport-specific adaptations and pathologies.  相似文献   

8.
对新型乒乓球性能的计算与研究   总被引:1,自引:0,他引:1  
据国际乒联透露,为提高乒乓球的观赏性,吸引群众,将把现用乒乓球的直径由38毫米改为40毫米,被称为“新型球”或“大球”,并将在1997年第44届世乒赛期间举行一次实验性的大球比赛。为了解大球的性能,探索其可行性,以尽快掌握其运动规律,对大球的参数和性能进行了计算与分析。如果制作大球的材料与小球的相同,计算结果:大球的质量增加0.2717克,材料体积增加0.1884厘米3,球的体积增大4.781厘米3,绕通过质心额状轴为转动惯量增加1.391立方厘米。如果用大球比赛,以与击小球同样的方式和大小相等的力来打击大球,大球的转速将比小球减少9.41转/秒(约减少1/5),速度减慢4.14米/秒(约减少1/10),但大球的性能发生了明显的变化。  相似文献   

9.
Our previous study has demonstrated that the swimmer’s wrist acceleration in the crawl stroke and the breaststroke had distinctive characteristics between subjects (Ohgiet al. 2000). In addition, stroke phase discrimination could be achieved for the crawl stroke by using the swimmer’s wrist acceleration. This study provides evidence that the swimmer’s tri-axial wrist acceleration could be used for stroke phase discrimination in the breaststroke. Swimmers’ triaxial wrist accelerations were measured and their underwater stroke paths calculated. The authors examined the characteristics of the wrist acceleration, such as a local maximum or minimum, with reference to the swimmers’ stroke paths. As a result, it was suggested that the three phases of the breaststroke, the recovery, the insweep and the outsweep, could be distinguished using thex-axis (ulnar-radial axis) and they-axis (distal-proximal axis) acceleration. This methodology allows us to identify which stroke phase would be changed in skill training or over training, and the acceleration sensor device has the potential to become a precise stroke pedometer or stroke monitoring tool in the near future.  相似文献   

10.
Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball–racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 “flat” one-handed backhand groundstrokes. Off-longitudinal axis ball–racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball–racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.  相似文献   

11.
Three-dimensional cinematography and the direct linear transformation method were used to obtain the coordinates of the landmarks of five right-handed collegiate tennis players. A 15-segment model was used to calculate the total body angular momentum about three orthogonal axes (X, parallel to the baseline; Y, normal to baseline and pointing towards the net; and Z, pointing upwards) passing through the centre of mass and to obtain the segmental contribution of the trunk, arms and legs. Most of the clockwise angular momentum about the X-axis was concentrated in the trunk and the racket-arm. Between the events of maximum external rotation and ball impact, the clockwise angular momentum about the X-axis of rotation of most body segments was reduced and the racket-arm gained clockwise angular momentum. The body angular momentum about the Y-axis of rotation had two distinct patterns and was the result of the lateral rotation of the trunk as the racket shoulder was elevated in preparation for impact. This body angular momentum was clockwise from the event of maximum external rotation to impact for the players with the greatest ball speed, whereas it was counterclockwise for the other players. The angular momentum about the Z-axis of rotation was small and lacked a consistent pattern. The largest source of angular momentum in the tennis serve derives from the remote angular momentum about the X- and Y-axes of rotation, which are then transferred from the trunk to the racket-arm and finally to the racket. Near impact, most of the angular momentum (75.1%) was concentrated in the racket-arm. Of the angular momentum of the racket-arm, the largest percentages were concentrated in the racket (35.9%) and the forearm segment (25.7%).  相似文献   

12.
Changes in angular momentum during the tennis serve   总被引:1,自引:0,他引:1  
Three-dimensional cinematography and the direct linear transformation method were used to obtain the coordinates of the landmarks of five right-handed collegiate tennis players. A 15-segment model was used to calculate the total body angular momentum about three orthogonal axes (X, parallel to the baseline; Y, normal to baseline and pointing towards the net; and Z, pointing upwards) passing through the centre of mass and to obtain the segmental contribution of the trunk, arms and legs. Most of the clockwise angular momentum about the X-axis was concentrated in the trunk and the racket-arm. Between the events of maximum external rotation and ball impact, the clockwise angular momentum about the X-axis of rotation of most body segments was reduced and the racket-arm gained clockwise angular momentum. The body angular momentum about the Y-axis of rotation had two distinct patterns and was the result of the lateral rotation of the trunk as the racket shoulder was elevated in preparation for impact. This body angular momentum was clockwise from the event of maximum external rotation to impact for the players with the greatest ball speed, whereas it was counterclockwise for the other players. The angular momentum about the Z-axis of rotation was small and lacked a consistent pattern. The largest source of angular momentum in the tennis serve derives from the remote angular momentum about the X- and Y-axes of rotation, which are then transferred from the trunk to the racket-arm and finally to the racket. Near impact, most of the angular momentum (75.1%) was concentrated in the racket-arm. Of the angular momentum of the racket-arm, the largest percentages were concentrated in the racket (35.9%) and the forearm segment (25.7%).  相似文献   

13.
目的:将惯性陀螺方法和基于标志点虚拟陀螺(a Marker-Based Virtual Gyroscope简称MBVG)方法用于网球发球时上臂内转动动作的监测,并对监测结果同视频拍摄方法研究结果进行比较。方法:惯性陀螺方法利用上臂和胸部两个陀螺对网球发球中上臂的转动进行捕捉。MBVG方法根据Vicon光学动作捕捉系统来设置标志点,利用标志点轨迹建立一种基于向量的方法,并利用几何方法确定转动关系。结果:(1)惯性陀螺方法与视频拍摄方法的结果在规范化时间的0.2~1区间段一致性很好,表明此方法在测量上臂内转动上是有效的;(2)MBVG方法能够用于陀螺超量程的情况,其数据能够反映真实的发球动作;(3)3种方法测得的网球发球数据在特征上彼此能够很好的吻合。结论:惯性陀螺方法与基于标志点虚拟陀螺方法能够有效地用于网球发球评估。  相似文献   

14.
In this study, we examined the relationship between upper limb joint movements and horizontal racket head velocity to clarify joint movements for developing racket head speed during tennis serving. Sixty-six male tennis players were videotaped at 200 Hz using two high-speed video cameras while hitting high-speed serves. The contributions of each joint rotation to horizontal racket velocity were calculated using vector cross-products between the angular velocity vectors of each joint movement and relative position vectors from each joint to the racket head. Major contributors to horizontal racket head velocity at ball impact were shoulder internal rotation (41.1%) and wrist palmar flexion (31.7%). The contribution of internal rotation showed a significant positive correlation with horizontal racket head velocity at impact (r = 0.490, P < 0.001), while the contribution of palmar flexion showed a significant negative correlation (r = ? 0.431, P < 0.001). The joint movement producing the difference in horizontal racket head velocity between fast and slow servers was shoulder internal rotation, and angular velocity of shoulder internal rotation must be developed to produce a high racket speed.  相似文献   

15.
This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants’ feet. The velocity of the ‘body + lifted mass’ system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p < 0.05). Within sessions and between sessions, mean and peak forces during DHP showed a strong agreement (CV < 3%, ICC > 0.94), mean and peak velocities showed a good agreement (CV < 9%, 0.78 < ICC < 0.92). It was concluded that DHP performance and its force-velocity relationships are highly reliable and can therefore be utilised as a tool to characterise individuals’ muscular profiles.  相似文献   

16.
Influence of pelvis rotation styles on baseball pitching mechanics   总被引:1,自引:0,他引:1  
Efficient, sequential timing is essential for upper level pitching. Interestingly, pitchers vary considerably in timing related elements of pitching style including pelvis rotation, arm cocking, stride leg behaviour, and pitch delivery time. The purpose of this study was to determine whether relationships exist among these elements by examining the overall style of pitchers exhibiting different pelvis rotation patterns. Pitching styles were defined by pelvis orientation at the instant of stride foot contact. Pitchers demonstrating a pelvis orientation greater than 30 degrees were designated as 'early rotators', while pitchers demonstrating a pelvis orientation less than 30 degrees were designated as 'late rotators'. Kinematic and temporal differences were associated with the two styles. During the arm cocking phase, early rotators showed significantly greater shoulder external rotation at the instant of stride foot contact, earlier occurrence of maximum pelvis rotation angular velocity, and shorter time taken to complete the phase. However, by the instant of maximum shoulder external rotation, early and late rotators appeared remarkably similar as no significant difference occurred in pelvis and arm orientations. Therefore, it appears that early and late rotators used different methods to achieve similar results, including throwing velocity. Significant differences in throwing arm kinetics were also found for 10 of the 11 measures in the study. As the pelvis assumed a more open position at stride foot contact, maximum kinetic values were found to both decrease in magnitude and occur at an earlier time within the pitch.  相似文献   

17.
This paper examines three methods to measure the upper arm rotation, the main contributor to produce a fast first serve in tennis. Accepted videography techniques were compared with a novel inertial gyroscope system and marker-based technique. A network of two inertial sensors on the upper arm and the chest was used to measure upper arm rotation angle and remove body artifacts. A marker-based virtual gyroscope (MBVG) was derived from Vicon marker positions in the standard Plug-in-Gait model using a vector-based method of marker trajectories and a series of geometric transformations. The results indicate that there is a close temporal feature match for all three methods when applied to the tennis serve. This paper shows that gyroscopes as well as the MBVG can be advantageous for tennis serve assessment.  相似文献   

18.
Baseball     
Efficient, sequential timing is essential for upper level pitching. Interestingly, pitchers vary considerably in timing related elements of pitching style including pelvis rotation, arm cocking, stride leg behaviour, and pitch delivery time. The purpose of this study was to determine whether relationships exist among these elements by examining the overall style of pitchers exhibiting different pelvis rotation patterns. Pitching styles were defined by pelvis orientation at the instant of stride foot contact. Pitchers demonstrating a pelvis orientation greater than 30° were designated as ‘early rotators’, while pitchers demonstrating a pelvis orientation less than 30° were designated as ‘late rotators’. Kinematic and temporal differences were associated with the two styles. During the arm cocking phase, early rotators showed significantly greater shoulder external rotation at the instant of stride foot contact, earlier occurrence of maximum pelvis rotation angular velocity, and shorter time taken to complete the phase. However, by the instant of maximum shoulder external rotation, early and late rotators appeared remarkably similar as no significant difference occurred in pelvis and arm orientations. Therefore, it appears that early and late rotators used different methods to achieve similar results, including throwing velocity. Significant differences in throwing arm kinetics were also found for 10 of the 11 measures in the study. As the pelvis assumed a more open position at stride foot contact, maximum kinetic values were found to both decrease in magnitude and occur at an earlier time within the pitch.  相似文献   

19.
The influence of moment of inertia on baseball/softball bat swing speed   总被引:1,自引:1,他引:0  
The speed at which a player can swing a bat is central to the games of baseball and softball, determining, to a large extent, the hit speed of the ball. Experimental and analytical studies of bat swing speed were conducted with particular emphasis on the influence of bat moment of inertia on swing speed. Two distinct sets of experiments measured the swing speed of colege baseball and fast-pitch softball players using weighted rods and modified bats. The swing targets included flexible targets, balls on a tee and machine pitched balls. Internal mass alterations provided a range of inertial properties. The average measured speeds, from 22 to 31 m s−1, are consistent with previous studies. Bat speed approximately correlates with the moment of inertia of the bat about a vertical axis of rotation through the batter's body, the speed generally decreasing as this moment of inertia increases. The analytical model assumes pure rotation of the batter/bat system about a vertical axis through the batter's body. Aerodynamic drag of the batter's arms and the bat is included in the model. The independent variable is bat moment of inertia about the rotation axis. There is reasonable agreement between the model and the measured speeds. Detailed differences between the two suggest the importance of additional degrees of freedom in determining swing speed.  相似文献   

20.
Abstract

The aim of this study was to investigate spatiotemporal and kinematic changes between the initial acceleration, transition and maximum velocity phases of a sprint. Sagittal plane kinematics from five experienced sprinters performing 50-m maximal sprints were collected using six HD-video cameras. Following manual digitising, spatiotemporal and kinematic variables at touchdown and toe-off were calculated. The start and end of the transition phase were identified using the step-to-step changes in centre of mass height and segment angles. Mean step-to-step changes of spatiotemporal and kinematic variables during each phase were calculated. Firstly, the study showed that if sufficient trials are available, step-to-step changes in shank and trunk angles might provide an appropriate measure to detect sprint phases in applied settings. However, given that changes in centre of mass height represent a more holistic measure, this was used to sub-divide the sprints into separate phases. Secondly, during the initial acceleration phase large step-to-step changes in touchdown kinematics were observed compared to the transition phase. At toe-off, step-to-step kinematic changes were consistent across the initial acceleration and transition phases before plateauing during the maximal velocity phase. These results provide coaches and practitioners with valuable insights into key differences between phases in maximal sprinting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏