首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Introduction

The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing.

Materials and methods:

Blood specimens from 100 volunteers in five diff erent serum vacuum tubes (Tube I: VACUETTE®, Tube II: LABOR IMPORT®, Tube III: S-Monovette®, Tube IV: SST® and Tube V: SST II®) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas® 6000 module. The significance of the diff erences between samples was assessed by paired Student’s t-test after checking for normality. The level of statistical significance was set at P < 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation.

Results and conclusions:

Basically, our validation will permit the laboratory or hospital managers to select the brand’s vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices.  相似文献   

2.

Introduction

The study of cardiac response to strenuous and continuous exercise is crucial to understanding the physiology of endurance. N-terminal proB-type natriuretic peptide (NT-proBNP) is a potential marker for monitoring myocardial wall stress, and troponins (TnT and TnI) are widely used in the diagnosis of cardiac ischemia and infarction. Strenuous exercise may generate transitory ischemia, myocardial stress, and diastolic left ventricular dysfunction, inducing the increased production of both these biomarkers. We measured changes in NT-proBNP and TnT in elite cyclists during a 3-week stage race, a model of strenuous exercise.

Materials and methods:

The study population was 9 professional cyclists participating in the 2011 Giro d’Italia. Pre-analytical and analytical phases scrupulously followed official recommendations. Anthropometric data, net energy expenditure and cardiac indexes (rate, diastolic and systolic blood pressure) were recorded. Blood samples were drawn pre-race (day −1) and at days 12 and 22; NT-proBNP and highly sensitive-troponin (Hs-TnT) concentrations were assayed and corrected for plasma volume changes.

Results:

Body-mass index decreased and energy expenditure increased by 52% during the race. NT-proBNP concentrations increased [day −1: 23.52 ng/L (9.67–34.33); day 12: 63.46 ng/L (22.15–93.31); P = 0.039; day 22: 89.26 ng/L (34.66–129.78) vs. day −1; P < 0.001] and correlated with heart rate (r = −0.51; P = 0.006), systolic pressure (r = 0.39; P = 0.046) and energy expenditure (r = 0.70; P < 0.001). TnT concentrations did not vary, but a widened TnT amplitude distribution was observed.

Conclusions:

Increases in NT-proBNP correlated with higher energy expenditure over a 3-week cycling stage race, possibly indicating myocardial stress.  相似文献   

3.

Background

Due to the high prevalence of hemolysis in specimens received from the emergency department (ED), several strategies have been proposed to improve sample quality, but none of these seem effective to overcome the problem. In a preliminary study we showed that the use of S-Monovette blood collection system was effective to lower the risk of hemolysis in venous blood samples collected from intravenous catheters. This study was hence aimed to verify whether the replacement of a conventional vacuum system with S-Monovette may be effective to reduce the burden of hemolysis in the daily practice of a large urban ED.

Materials and methods

The study was divided in two observational periods of 4 months each. In the former period, blood was collected from intravenous catheters using BD Vacutainer SST II Plus plastic serum tubes, whereas in the latter period the blood was drawn from intravenous catheters using S-Monovette blood tubes in aspiration mode. Sample hemolysis was automatically assessed in all serum samples by photometrical measurement.

Results

The total number of hemolysed serum specimens was 624/14155 (4.41%) in the first phase of the study, and 342/13319 (2.57%) in the second phase of the study (P < 0.001).

Conclusion

Results of our study confirm that the introduction of the Sarstedt S-Monovette blood tubes has reduced the hemolysis rate in the emergency department compared to the previously used BD Vacutainer® SST II Plus plastic serum tubes.Key words: preanalytical phase, hemolysis, blood specimen collection, catheter, emergency department  相似文献   

4.

Introduction

The aim of the present study was to validate prothrombin time (PT) international normalized ratio (INR) results obtained using Steelex test reagents and a Steelex coagulometer (Steelex Scientific Instrument Company, Beijing, China), in comparison with use of a well-established standard test employing Pacific Hemostasis reagents (Fisher Diagnostics, Middletown, VA, USA) and Teco Coatron A4 coagulometer (Teco Medical Instruments GmbH, Neufahrn, Germany).

Materials and methods:

Between- and within-day coefficients of variation (CVs) of both assays were calculated using control samples provided by the test manufacturers. Samples from 90 subjects were collected and INR values were determined in a double-blind parallel manner employing both systems.

Results:

The within-day coefficients of variation (CVs) in INR estimates ranged from 2.6% (INR = 1.12) to 3.1% (INR = 2.51) for the Steelex system and from 2.1% (INR = 1.09) to 1.8% (INR = 2.8) for the Pacific test; the between-day values ran from 3.4% (INR = 1.16) to 7.9% (INR = 2.64) and from 3.3% (INR = 1.1) to 2.3% (INR = 2.7), respectively. Passing-Bablok fit of the of the Steelex and Pacific methods yielded the equation: Steelex INR = 0.85 (0.79–0.91) × Pacific INR + 0.12 (−0.02–0.21), whereas the CUSUM linearity P value was < 0.01. The mean bias as determined by the Bland-Altman test was −0.156 (−0.912–0.600).

Conclusion:

The results obtained using Steelex reagents and the M600H coagulometer are not equivalent to those obtained using Pacific Hemostasis reagents and a Teco Coatron A4 coagulometer, at least in the therapeutic range.  相似文献   

5.

Introduction:

Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer® Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer® RST blood collection tube in reference with the BD Vacutainer® Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA).

Materials and methods:

Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality.

Results:

Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C.

Conclusions:

Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.  相似文献   

6.

Introduction:

Two Italian adults arrived at the Emergency Department referring diarrhea, nausea and vomiting for 4 days; weakness, fatigue and visual hallucinations were also complained of. Patients reported the ingestion of some leaves of a plant, which they supposed to be “donkey ears”, a week before. Physical examination showed hypotension and bradycardia and ECG examination disclosed sinus rhythm and repolarization abnormalities (scooping of the ST-T complex) in both patients and a 2:1 AV block in the man.

Materials and methods:

Digoxin concentration was evaluated twice for each patient (at the admission and after 4 hours) by the automated immunoassay system ADVIA Centaur®. Digitoxin concentration was evaluated by liquid chromatography-mass spectrometry (LC-MS/MS).

Results:

Despite clinical picture was suggestive of digitalis intoxication, digoxin levels were undetectable. Due to the more severe clinical picture, the male patient was treated with anti-digoxin antibodies (Digifab®) achieving a good clinical improvement and remission of the AV block within two hours. Initial diagnosis was confirmed by LC-MS/MS showing high digitoxin concentrations, but digoxin was undetectable. Patients remained stable and 48 hours later were discharged from the hospital.

Conclusion:

Whereas digoxin determination frequently relies on monoclonal antibodies which do not cross-react to digitoxin, polyclonal antibodies constituting Digifab® recognize a large spectrum of cardiac glycosides, including digitoxin. This report emphasizes the primary role of the clinical approach to patients in the emergency setting and how an active communication and a continuous sharing of professional experiences between Laboratory and Clinicians ensure an early and correct diagnosis.  相似文献   

7.

Introduction:

Blood collection through intravenous lines frequently causes spurious hemolysis. Due to specific structure, the tube holder Holdex® (Greiner Bio-One GmbH, Kremsmuenster, Austria) is supposed to prevent erythrocyte injury in samples collected from catheters, so that we planned a specific study to support this hypothesis.

Materials and methods:

Blood was collected from emergency department (ED) patients with 20-gauge catheter. In patients with odd order numbers, first and second tubes were collected with conventional holder (BD Vacutainer One Use Holder, Becton Dickinson, Milan, Italy) and the third with Holdex, whereas in even patients first and second tubes were drawn with Holdex and the third using BD Vacutainer One Use Holder. The first tube was discarded, whereas the second and third were centrifuged and serum was tested for potassium, lactate dehydrogenase (LD) and hemolysis index.

Results:

The final study population consisted in 60 ED patients. Concentrations of potassium (4.25 vs. 4.16 mmol/L; P = 0.031), LD (498 vs. 459 U/L; P = 0.039) and cell-free hemoglobin (0.42 vs. 0.22 g/L; P = 0.042) were higher in samples collected with BD Vacutainer One Use Holder than with Holdex. The mean bias of cell-free hemoglobin was −0.4 g/L in samples collected with Holdex. Although the frequency of samples with cell-free hemoglobin > 0.5 g/L was identical (17/60 vs. 17/60; P = 1.00), the frequency of those with concentrations >3.0 g/L was higher using BD Vacutainer One Use Holder than Holdex (4/60 vs. 0/60; P = 0.042).

Conclusions:

The use of Holdex for drawing blood from intravenous lines may be effective for reducing gross hemolysis.  相似文献   

8.

Introduction:

The measurement of cardiospecific troponins is pivotal in the diagnostic and prognostic approach of patients with suspected acute myocardial infarction (AMI). However, no information is available on the commutability of results between the novel highly-sensitive (HS) troponin T (TnT) and I (TnI) immunoassays.

Materials and methods:

The study population consisted in 47 consecutive patients presenting at the emergency department (ED) of the Academic Hospital of Parma with suspected AMI. TnI was measured with the novel prototype Beckman Coulter HS-AccuTnI immunoassay on Access 2, whereas TnT was measured with the Roche HS-TnT immunoassay on Cobas.

Results:

Eight out of the 47 patients (17%) were finally diagnosed as having an AMI. The overall correlation between TnT and TnI for total patient group was acceptable (r = 0.944; P < 0.01). Nevertheless, when the analysis of data was carried out in separate groups according to the final diagnosis of AMI, two different equation results were obtained, i.e., HS-TnT = HS-AccuTnI × 0.349 + 20 (r = 0.823; P < 0.01) in non-AMI patients, and HS-TnT = HS-AccuTnI × 0.134 + 67 (r = 0.972; P < 0.01) in those with AMI.

Conclusions:

This study suggests the existence of two biological relationships between TnI and TnT in plasma, depending on the source of release from the myocardium. Moreover, the non-commutability of data between HS-TnT and HS-AccuTnI jeopardizes the clinical decision making, makes it impossible to calculate the delta or reference change value using the two biomarkers and to finally establish a reliable kinetics of troponin release from the injured myocardium.  相似文献   

9.

Introduction

The collected and shipped blood samples are exposed to a various extra-analytical factors prior to analysis. The aim of the study was to determine the stability of analytes in serum gel tubes and plain tubes exposed to a range of storage temperatures and times after centrifugation.

Materials and methods:

Fifteen healthy volunteers were recruited and venous blood was collected into four tubes, two with and two without gel separator. Analyzing the baseline samples in 30 min, all were stored at 4ºC or 24ºC for 6, 12, 18, 24, 30, 36, 48 and 72 hours and 1 week. Sixteen biochemical anaytes were measured on each sample. Variations remained under the desirable bias considered as clinically insignificant.

Results:

On day three, most analytes remained stable including albumin, protein, creatinine, cholesterol, triglycerides, gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), lactate dehydrogenase (LD) regardless of tube types. Glucose concentration decreased markedly (P = 0.001) beginning from the first hours of storage in plain serum. The stability maximized for the analytes including glucose, total bilirubin, urea nitrogen (BUN), uric acid stored at 4 ºC in gel tubes. Aspartate aminotransferase (AST) activity increased significantly (P = 0.002) up to 48-h, however bias was not significant clinically. High density lipoprotein (HDL) concentration was stable in gel tubes at 24 ºC, in plain tubes at 4 ºC stored up to 36-h.

Conclusion:

Serum gel or non-gel tubes might be used interchangeably for 11 analytes chilled or at 24 ºC, whereas some restrictions must be applied for glucose, AST, BUN, HDL, and uric acid.  相似文献   

10.

Introduction

Diagnosis and monitoring of diabetes mellitus in sub-Saharan Africa, based on blood analyses, are hampered by infrastructural and cultural reasons. The first aim of this study was to evaluate the diagnostic accuracy of glycated nail proteins for diabetes mellitus. The second aim was to compare the course of short- and long-term glycemic biomarkers after 6 months of antidiabetic treatment. These objectives should support our hypothesis that glycated nail proteins could be used as an alternative glycemic biomarker.

Materials and methods

This case-control study consisted of 163 black diabetics and 67 non-diabetics of the South Kivu (Democratic Republic of Congo). Diagnostic accuracy of glycated nail proteins was evaluated using ROC curve analysis. At the start of the study, glycated nail protein concentrations were compared between diabetics and non-diabetics, using a nitro blue tetrazolium (NBT) colorimetric method. In a subgroup of 30 diabetics, concentrations of glycated nail proteins, fasting glucose (Accu-Chek® Aviva), serum fructosamine (NBT) and HbA1c (DCA-2000+®) were measured at start and after 6 months.

Results

ROC analysis yielded an AUC of 0.71 (95% confidence interval (CI): 0.65-0.76) and a cut-off point of 3.83 μmol/g nail. Concentration of glycated nail proteins was significantly higher (P < 0.001) in diabetics in comparison with non-diabetics. After 6 months of antidiabetic treatment, a significant drop in the fasting glucose concentration (P = 0.017) and concentration of glycated nail proteins (P = 0.008) was observed in contrast to serum fructosamine and HbA1c.

Conclusions

Measurement of glycated nail proteins could be used to diagnose and monitor diabetes mellitus in sub-Saharan Africa.Key words: fasting glucose concentration, fructosamine, hemoglobin A1c protein, nails, sub-Saharan Africa, diabetes mellitus  相似文献   

11.

Introduction:

Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration.

Materials and methods:

Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated.

Results:

There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2–8 °C, 7 days at −20 °C, 3 months at −80 °C.

Conclusion:

Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement.  相似文献   

12.

Introduction:

This study aimed to assess whether heart fatty acid-binding protein (H-FABP) and glycogen phosphorylase isoenzyme BB (GPBB) could be used for the accurate diagnosis of acute myocardial infarction (AMI) in acute coronary syndrome (ACS) patients.

Materials and methods:

The study included 108 ACS patients admitted to a coronary unit within 3 h after chest pain onset. AMI was distinguished from unstable angina (UA) using a classical cardiac troponin I (cTnI) assay. H-FABP and GPBB were measured by ELISA on admission (0 h) and at 3, 6, 12, and 24 h after admission; their accuracy to diagnose AMI was assessed using statistical methods.

Results:

From 92 patients with ACS; 71 had AMI. H-FABP and GPBB had higher peak value after 3 h from admission than cTnI (P = 0.001). Both markers normalized at 24 h. The area under the receiver operating characteristic curves was significantly greater for both markers in AMI patients than in UA patients at all time points tested, including admission (P < 0.001). At admission, the H-FABP (37%) and GPBB (40%) sensitivities were relatively low. They increased at 3 and 6 h after admission for both markers and decreased again after 24 h. It was 40% for H-FABP and approximately 2-times lower for GPBB (P < 0.01). In AMI patients, both biomarkers had similar specificities, positive- and negative-predictive values, positive and negative likelihood ratios, and risk ratios for AIM.

Conclusion:

H-FABP and GPBB can contribute to early AMI diagnosis and can distinguish AMI from UA.  相似文献   

13.
The estimation of electrolytes like sodium (Na+), potassium (K+) and chloride (Cl) using direct and indirect ion-selective electrodes (ISE) is a routine laboratory practice. Interferents like proteins, triglycerides, drugs etc. are known to affect the results. The present study was designed to look into the effect of increasing glucose concentrations on estimation of Na+, K+ and Cl by direct and indirect ISE. Pooled sera was mixed with glucose stock solution (20 g/dL) prepared in normal saline to obtain glucose concentrations ranging from ~100 to ~5000 mg/dL. Na+, K+ and Cl levels were estimated by direct and indirect ISE analyzers and results were statistically analysed using ANOVA and Pearson’s correlation. Similar experiment was also performed in 24 h urine sample from healthy subjects. Significant difference was observed between Na+ and Cl measurements by direct and indirect ISE, with indirect ISE values being consistently higher than direct ISE. Besides this, significant difference was observed amongst Na+ and Cl values from baseline values obtained by indirect ISE at glucose concentrations ≥2486 mg/dL. However, no such difference was observed with direct ISE. Na+ and Cl estimation by indirect ISE showed significant negative correlation with glucose concentration, more so, above ~2000 mg/dL. K+, however, showed no significant difference with varying glucose. Similar results were observed in 24 h urine samples with a significant difference observed amongst Na+ and Cl values at ≥2104 mg/dL glucose. Thus we conclude that high glucose concentrations interfere significantly in estimation of Na+ and Cl by indirect ISE in serum as well as urine.

Electronic supplementary material

The online version of this article (doi:10.1007/s12291-015-0522-0) contains supplementary material, which is available to authorized users.  相似文献   

14.

Introduction:

Optimal storage of serum specimens in central laboratories for a long period for multicenter reference interval studies, or epidemiologic studies remains to be determined. We aimed to examine the analytical stability of chemistry analytes following numerous freeze-thaw and long term storage.

Materials and methods:

Serum samples were obtained from 15 patients. Following baseline measurement, sera of each subject were aliquoted and stored at −20 °C for two experiments. A group of sera were kept frozen for up to 1, 2 and 3 months and then analyzed for stability. The other experiment consisted of one to ten times of freeze and thaw cycles. Total of 17 chemistry analytes were assayed at each time point. The results were compared with those obtained from the initial analysis of fresh samples. Median or mean changes from baseline (T0) concentrations were evaluated both statistically and clinically according to the desirable bias.

Results:

Of the analytes studied, aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatine kinase (CK), gamma-glutamyl transferase (GGT), direct bilirubin, glucose, creatinine, cholesterol, triglycerides, high density lipoprotein (HDL) were stable in all conditions. Blood urea nitrogen (BUN), uric acid, total protein, albumin, total bilirubin, calcium, lactate dehydrogenase (LD) were changed significantly (P < 0.005).

Conclusions:

As a result, common clinical chemistry analytes, with considering the variability of unstable analytes, showed adequote stability after 3 months of storage in sera at −20 °C, or up to ten times of freeze-thaw cycle. All the same, such analysis can only be performed for exceptional cases, and this should be taken into account while planning studies.  相似文献   

15.

Introduction

Nowadays, on-a-chip capillary electrophoresis is a routine method for the detection of PCR fragments. The Agilent 2100 Bioanalyzer was one of the first commercial devices in this field. Our project was designed to study the characteristics of Agilent DNA 1000 kit in PCR fragment analysis as a part of circulating tumour cell (CTC) detection technique. Despite the common use of this kit a complex analysis of the results from a long-term project is still missing.

Materials and methods

A commercially available Agilent DNA 1000 kit was used as a final step in the CTC detection (AdnaTest) for the determination of the presence of PCR fragments generated by Multiplex PCR. Data from 30 prostate cancer patients obtained during two years of research were analyzed to determine the trueness and precision of the PCR fragment size determination. Additional experiments were performed to demonstrate the precision (repeatability, reproducibility) and robustness of PCR fragment concentration determination.

Results

The trueness and precision of the size determination was below 3% and 2% respectively. The repeatability of the concentration determination was below 15%. The difference in concentration determination increases when Multiplex-PCR/storage step is added between the two measurements of one sample.

Conclusions

The characteristics established in our study are in concordance with the manufacturer’s specifications established for a ladder as a sample. However, the concentration determination may vary depending on chip preparation, sample storage and concentration. The 15% variation of concentration determination repeatability was shown to be partly proportional and can be suppressed by proper normalization.Key words: lab-on-a-chip devices, capillary electrophoresis, multiplex PCR, circulating tumour cells, Agilent DNA 1000 kit  相似文献   

16.

Introduction

Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates after perinatal asphyxia. Therefore, our aim was to assess the diagnostic accuracy of sNGAL for AKI in premature asphyxiated neonates.

Materials and methods

AKI was defined in the third day of life (DOL 3) as a serum creatinine (sCr) increase ≥ 26.5 μmol/L from baseline (the lowest previous sCr). According to the increase of sCr, AKI patients were divided in AKIN1 (sCr increase up to 1.9 baseline) and AKIN2 (sCr increase from 2.0 to 2.9 baseline). sNGAL levels were measured on DOL 1, 3 and 7.

Results

AKI was diagnosed in 73 (0.676) of 108 enrolled premature asphyxiated neonates. Sixty one patients (0.836) were classified in AKIN1 and 12 patients (0.164) in AKIN2. sNGAL reached the maximal concentrations on DOL 1 within 4 hours after admission to NICU, being higher in AKI compared with no-AKI group (160.8 ± 113.1 vs. 87.1 ± 81.6; P < 0.001) as well as in AKIN2 compared with AKIN1 group (222.8 ± 112.9 vs. 147.8 ± 109.9; P < 0.001). The best areas under the receiver operating characteristic curves (AUC) for prediction of AKI were 0.72 [95% (0.62-0.80) P < 0.001] on DOL1 at 2h and 0.72 [95% (0.63-0.80) P < 0.001] at 4th hour after admission respectively. The corresponding sNGAL cutoff concentrations were 84.87 ng/mL (sensitivity 69.0% and specificity 71.9%) and 89.43 ng/mL (sensitivity 65.7% and specificity 74.3%).

Conclusions

In premature asphyxiated neonates sNGAL measured within the first 4 hours of DOL 1 is predictive of the occurrence and severity of AKI. Therefore, plasma levels of NGAL may be used for early diagnosis of AKI in these patients.Key words: serum neutrophil gelatinase-associated lipocalin, acute kidney injury, premature neonates, biomarker  相似文献   

17.

Background

The preanalytical phase represents the major source of variability in laboratory diagnostics. Our aim was to assess to what extent underfilling of primary blood tubes may impact upon routine coagulation testing.

Materials and methods:

Blood was drawn by syringe from 21 healthy volunteers and 6 patients on warfarin therapy, and immediately transferred into 3.6 mL vacuum tubes containing 3.2% sodium citrate (Terumo Europe N.V., Leuven, Belgium). All tubes were filled using standardized volumes of whole blood to produce scalar amounts of filling: 3.6 mL (i.e., 100%), 3.2 mL (89%), 2.8 mL (78%) and 2.4 mL (67%). Samples were mixed and centrifuged at 1300 × g for 10 min. The plasma was tested for prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FBG) on ACL TOP (Instrumentation Laboratory - IL, Milan, Italy), using IL reagents. A polynomial plot was derived for each parameter from interpolation of clotting values obtained with different percentages of filling, and these plots were compared with quality specifications (± 2.0 for PT, ± 2.3 for APTT and ± 4.8 for FBG) to calculate the minimal filling volume required to produce clinically acceptable results.

Results:

The equations were (PF, Percentage of filling): PT (sec) = 3.375 × PF^2–6.255 × PF + 17.806 (r = 0.980); APTT (sec) = 8.925 × PF^2–23.578 × PF + 46.356 (r = 0.979); and FBG (mg/dL) = −311.5 × PF^2 + 422.1 × PF + 147.07 (r = 0.994). According to these equations, the minimum allowed thresholds of blood tubes filling were > 61% for PT, > 87% for APTT and > 71% for FBG.

Conclusions:

Our results confirm that routine coagulation testing performed on underfilled tubes may generate biased and clinically misleading test results. This is particularly critical for APTT, wherein tubes filled at less than ∼90% generate unreliable data. The FBG and the PT seem more resistant to underfilling, clinical significant biases being observed only where blood tubes were filled at less than ∼60 and ∼70%, respectively.  相似文献   

18.

Introduction

The aim of our study was to investigate the extent to which Instructions to authors of the Croatian open access (OA) journals are addressing ethical issues. Do biomedical journals differ from the journals from other disciplines in that respect? Our hypothesis was that biomedical journals maintain much higher publication ethics standards.

Materials and methods

This study looked at 197 Croatian OA journals Instructions to authors to address the following groups of ethical issues: general terms; guidelines and recommendations; research approval and registration; funding and conflict of interest; peer review; redundant publications, misconduct and retraction; copyright; timeliness; authorship; and data accessibility. We further compared a subset of 159 non-biomedical journals with a subset of 38 biomedical journals. Content analysis was used to discern the ethical issues representation in the instructions to authors.

Results

The groups of biomedical and non-biomedical journals were similar in terms of originality (χ2 = 2.183, P = 0.140), peer review process (χ2 = 0.296, P = 0.586), patent/grant statement (χ2 = 2.184, P = 0.141), and timeliness of publication (χ2 = 0.369, P = 0.544). We identified significant differences among categories including ethical issues typical for the field of biomedicine, like patients (χ2 = 47.111, P < 0.001), and use of experimental animals (χ2 = 42.543, P < 0.001). Biomedical journals also rely on international editorial guidelines formulated by relevant professional organizations heavily, compared with non-biomedical journals (χ2 = 42.666, P < 0.001).

Conclusion

Low representation or absence of some key ethical issues in author guidelines calls for more attention to the structure and the content of Instructions to authors in Croatian OA journals.Key words: instructions to authors, publication ethics, publication standards, open access, OA, research integrity  相似文献   

19.

Introduction:

Metabolic syndrome (MetS) is a multifactorial disorder in which dyslipidemia plays an important role. Fatty acid-binding protein 2 (FABP 2) is responsible for transport of free fatty acids in the intestinal endothelium cells. FABP2-genetic variants might affect plasma lipid concentrations and intracellular lipid transport. The aim of this study was to investigate the association between FABP2 Ala54Thr genetic polymorphism and metabolic syndrome and some biochemical and anthropological parameters in elderly subjects.

Materials and methods:

This cross-sectional study included 140 men and 176 women older than 70 years. Fasting serum concentration of glucose, lipid parameters, total proteins and C-reactive protein were determined by standardized methods. Presence (MetS(+)) or absence (MetS(−)) of MetS was determined according to criteria of the International Diabetes Federation. FABP2 genetic polymorphism Ala54Thr (rs1799883) was genotyped with PCR-RFPL.

Results:

The genotype frequencies for Ala/Ala, Ala/Thr and Thr/Thr genotype were 60, 36 and 6 in MetS(−), and 131, 70 and 13 in MetS(+), respectively, without statistical significance (P = 0.567). Ala/Ala genotype was a subgroup of non-carriers, while Ala/Thr and Thr/Thr genotypes were Thr54-carriers. Median triglyceride concentration was significantly lower in carriers then in non-carriers for whole MetS(+) group (P = 0.050); there were no significant difference between men with MetS (P = 0.144), but there was a difference between women with MetS (P = 0.020). T-test showed that mean HDL cholesterol concentrations in MetS(+) group for Thr54-carriers was significantly higher in whole group (P = 0.001), and for both genders (men P = 0.039; women P = 0.004) as compared to non-carriers.

Conclusions:

FABP2 genetic polymorphism is associated with lower triglyceride and higher HDL-cholesterol concentrations in elderly subjects with MetS. This genetic variation might be a useful marker for understanding dyslipidemia in MetS.  相似文献   

20.

Background

In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

Material and methods

Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.

Results

The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).

Conclusion

Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume  相似文献   