首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ABSTRACT

The aims of the present study were to provide an in-depth comparison of inter-limb asymmetry and determine how consistently asymmetry favours the same limb during different vertical jump tests. Eighteen elite female under-17 soccer players conducted unilateral squat jumps (SJ), countermovement jumps (CMJ) and drop jumps (DJ) on a portable force platform, with jump height, peak force, concentric impulse and peak power as common metrics across tests. For the magnitude of asymmetry, concentric impulse was significantly greater during the SJ test compared to CMJ (p = 0.019) and DJ (p = 0.003). No other significant differences in magnitude were present. For the direction of asymmetry, Kappa coefficients revealed fair to substantial levels of agreement between the SJ and CMJ (Kappa = 0.35 to 0.61) tests, but only slight to fair levels of agreement between the SJ and DJ (Kappa = ?0.26 to 0.18) and CMJ and DJ (Kappa = ?0.13 to 0.26) tests. These results highlight that the mean asymmetry value may be a poor indicator of true variability of between-limb differences in healthy athletes. The direction of asymmetry may provide a useful monitoring tool for practitioners in healthy athletes, when no obvious between-limb deficit exists.  相似文献   

2.
The purpose of this investigation was to analyse the concurrent validity and reliability of an iPhone app (called: My Jump) for measuring vertical jump performance. Twenty recreationally active healthy men (age: 22.1 ± 3.6 years) completed five maximal countermovement jumps, which were evaluated using a force platform (time in the air method) and a specially designed iPhone app. My jump was developed to calculate the jump height from flight time using the high-speed video recording facility on the iPhone 5 s. Jump heights of the 100 jumps measured, for both devices, were compared using the intraclass correlation coefficient, Pearson product moment correlation coefficient (r), Cronbach’s alpha (α), coefficient of variation and Bland–Altman plots. There was almost perfect agreement between the force platform and My Jump for the countermovement jump height (intraclass correlation coefficient = 0.997, P < 0.001; Bland–Altman bias = 1.1 ± 0.5 cm, P < 0.001). In comparison with the force platform, My Jump showed good validity for the CMJ height (= 0.995, P < 0.001). The results of the present study showed that CMJ height can be easily, accurately and reliably evaluated using a specially developed iPhone 5 s app.  相似文献   

3.
Examining a countermovement jump (CMJ) force-time curve related to net impulse might be useful in monitoring athletes' performance. This study aimed to investigate the reliability of alternative net impulse calculation and net impulse characteristics (height, width, rate of force development, shape factor, and proportion) and validate against the traditional calculation in the CMJ. Twelve participants performed the CMJ in two sessions (48 hours apart) for test–retest reliability. Twenty participants were involved for the validity assessment. Results indicated intra-class correlation coefficient (ICC) of ≥ 0.89 and coefficient of variation (CV) of ≤ 5.1% for all of the variables except for rate of force development (ICC = 0.78 and CV = 22.3%). The relationship between the criterion and alternative calculations was r = 1.00. While the difference between them was statistically significant (245.96 ± 63.83 vs. 247.14 ± 64.08 N s, p < 0.0001), the effect size was trivial and deemed practically minimal (d = 0.02). In conclusion, variability of rate of force development will pose a greater challenge in detecting performance changes. Also, the alternative calculation can be used practically in place of the traditional calculation to identify net impulse characteristics and monitor and study athletes' performance in greater depth.  相似文献   

4.
Whilst previous research has highlighted significant relationships between golfers’ clubhead velocity (CHV) and their vertical jump height and maximum strength, these field-based protocols were unable to measure the actual vertical ground reaction force (vGRF) variables that may correlate to performance. The aim of this study was to investigate relationships between isometric mid-thigh pull (IMTP), countermovement jump (CMJ), squat jump (SJ) and drop jump (DJ) vGRF variables and CHV in highly skilled golfers. Twenty-seven male category 1 golfers performed IMTP, CMJ, SJ and DJ on a dual force platform. The vertical jumps were used to measure positive impulse during different stretch-shortening cycle velocities, with the IMTP assessing peak force (PF) and rate of force development (RFD). Clubhead velocity was measured using a TrackMan launch monitor at a golf driving range. Pearsons correlation coefficient analyses revealed significant relationships between peak CHV and CMJ positive impulse (r = 0.788, < 0.001), SJ positive impulse (r = 0.692; < 0.001), DJ positive impulse (r = 0.561, < 0.01), PF (r = 0.482, < 0.01), RFD from 0–150 ms (r = 0.343, < 0.05) and RFD from 0–200 ms (r = 0.398, < 0.05). The findings from this investigation indicate strong relationships between vertical ground reaction force variables and clubhead velocity.  相似文献   

5.
Length changes in vastus lateralis fascicles were measured in vivo using ultrasonography during one-legged squat jumps (SJ), counter movement jumps (CMJ), and drop jumps (DJ) in the sledge apparatus (n = 9). Patellar tendon forces were recorded simultaneously with an optic fiber technique from 4 subjects. Fascicle length changes were compared with muscletendon unit length changes calculated from kinematic recordings. In general, the tendomuscular and fascicle length changes demonstrated similar patterns. During SJ the fascicles showed shortening throughout the action while during CMJ and DJ they underwent stretch-shortening cycle. In DJ greater muscular activity in braking phase.  相似文献   

6.
ABSTRACT

The aim of this investigation was to assess the reliability and validity of the Fitjump system. Fifty-seven participants (age = 22.62 ± 5.24 years, height = 180.69 ± 12.53 cm, body mass = 75.61 ± 9.56 kg) performed three countermovement jump (CMJ) and squat jump (SJ) with a 1-week interval for test and retest reliability. For validity, the participants performed the same jump protocol on the force platform while being simultaneously measured with the Fitjump system. There was excellent test–retest reliability of the Fitjump system for CMJ and SJ with high intraclass correlation coefficient (ICCs) (0.97 and 0.97, respectively), low coefficient variation (CVs) (2.3% and 2.4%, respectively), and low typical error of estimate [(TEE (%)] (4.0% and 4.4%, respectively). For validity, ICCs were extremely high for CMJ and SJ (0.93 and 0.94, respectively), with low TEE (%) (2.9% and 2.0%, respectively). However, Fitjump overestimated jump height for CMJ and SJ (3.54 and 3.37 cm, respectively; p < 0.001) when compared with the force platform. As a conclusion, the Fitjump system demonstrated excellent test–retest reliability and high relationship with a systematic bias for validity. Therefore, the Fitjump system can be used as a portable tool for monitoring vertical jump changes over time, but it should not be used interchangeably with a force platform.  相似文献   

7.
The aim of this study was to evaluate the reliability of two long jump tasks and their ability to predict 10 m sprint performance in elite adolescent female athletes. Eight junior national-level female track and field athletes completed three standing (SLJ) and reactive long jumps (RLJ) on portable force plates, followed by three 10 m sprints. Intra-class correlation coefficients (ICC) and coefficients of variation (CV) were calculated to examine reliability. Linear regression results identified the best predictor of average and best 10 m sprint time from the jump kinematic and kinetic measures. The ICCs and CVs indicated good reliability for the majority of kinetic measures however, better reliability was reported for the SLJ. The SLJ was a good predictor of best and average 10 m sprint time, with average horizontal power the best predictor of performance (best; R 2 = 0.751, p = 0.003, Standard Error of Estimate (SEE)% = 2.2 average; R 2 = 0.708, p = 0.005, SEE% = 2.5).  相似文献   

8.
ABSTRACT

We aimed to determine key biomechanical parameters explaining age-related jumping performance differences in youth elite female soccer players. Multiple biomechanical parameters from countermovement (CMJ) squat (SJ) and drop (DJ) jump testing of elite female soccer players (n = 60) within the same national training centre were analysed across ages 9-11y, 12-14y and 15-19y. Effects of age group and jump type on jump height were found, with the older jumping higher than the younger groups in all jumps (P < 0.05). For DJ, higher reactive strength index was found for older, compared to each younger group (P < 0.001). For CMJ and SJ, peak power was the most decisive characteristic, with significant differences between each group for absolute peak power (P < 0.0001) and body-weight-normalised peak power in CMJ (57 ± 7W/kg, 50 ± 7W/kg, 44.7 ± 5.5W/kg; P < 0.05) and between the older and each younger group in SJ (56.7 ± 7.1W/kg, 48.9 ± 7.1W/kg, 44.6 ± 6W/kg; P < 0.01). Age-related differences in jumping performance in youth elite female soccer players appear to be due to power production during standing jumps and by the ability to jump with shorter ground contact times during reactive jumps.  相似文献   

9.
Abstract

The aim of the present study was to investigate the kinematic and kinetic differences in the execution of vertical jumps between individuals with good and poor ankle dorsiflexion. Fifteen physical education students were assigned to the flexible group (FG), while another 15 were assigned to the inflexible group (IFG). The two groups executed countermovement jumps (CMJ) and drop jumps from a 60 cm height (DJ60). For the CMJ, the FG jumped higher (32.0 ± 4.0 cm vs. 30.2 ± 4.9 cm, P = 0.27) and used a greater range of motion in all leg joints. The IFG jumpers raised their heels off the ground and had a greater horizontal distance between the centre of mass of the trunk and the centre of the hip joint (LCMh 25.6 ± 3.4 cm vs. 30.9 ± 4.3 cm, P < 0.001). In the DJ60 the FG jumped higher (22.4 ± 5.9 cm vs. 19.5 ± 4.6 cm, P = 0.14) with a greater vertical shift of the body centre of mass (BCM) (S = 0.45 ± 0.11 cm vs. 0.36 ± 0.05 cm, P < 0.01) and better joint coordination. The IFG jumpers changed the position of their trunk and heels depending on the jump type. Trainers should reconsider the technical issues of vertical jumps according to the flexibility of the ankle joint.  相似文献   

10.
This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants’ feet. The velocity of the ‘body + lifted mass’ system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p < 0.05). Within sessions and between sessions, mean and peak forces during DHP showed a strong agreement (CV < 3%, ICC > 0.94), mean and peak velocities showed a good agreement (CV < 9%, 0.78 < ICC < 0.92). It was concluded that DHP performance and its force-velocity relationships are highly reliable and can therefore be utilised as a tool to characterise individuals’ muscular profiles.  相似文献   

11.
This study aimed to examine aspects of validity and reliability of the Test of Gross Motor Development-2 (TGMD-2) in Filipino children with intellectual disability. Content and construct validity were verified, as well as inter-rater and intra-rater reliability. Two paediatric physiotherapists tested 81 children with intellectual disability (mean age = 9.29 ± 2.71 years) on locomotor and object control skills. Analysis of covariance, confirmatory factor analysis and analysis of variance were used to test validity, while Cronbach’s alpha, intra-class correlation coefficients (ICC) and Bland–Altman plots were used to examine reliability. Age was a significant predictor of locomotor and object control scores (P = 0.004). The data fit the hypothesised two-factor model with fit indices as follows: χ2 = 33.525, DF = 34, P = 0.491, χ2/DF = 0.986. As hypothesised, gender was a significant predictor for object control skills (P = 0.038). Participants’ mean scores were significantly below mastery (locomotor, P < 0.001; object control, P < 0.001). Cronbach’s alpha was 0.830 for locomotor and 0.792 for object control components. ICC for locomotor and object control scores ranged from 0.995 to 0.998, suggesting excellent intra-rater and inter-rater reliability, confirmed by Bland–Altman analysis. This study provides evidence of sufficient content and construct validity, internal consistency and rater reliability of TGMD-2 for Filipino children with intellectual disability.  相似文献   

12.
The Microsoft Xbox One Kinect? (Kinect V2) contains a depth camera that can be used to manually identify anatomical landmark positions in three-dimensions independent of the standard skeletal tracking, and therefore has potential for low-cost, time-efficient three-dimensional movement analysis (3DMA). This study examined inter-session reliability and concurrent validity of the Kinect V2 for the assessment of coronal and sagittal plane kinematics for the trunk, hip and knee during single leg squats (SLS) and drop vertical jumps (DVJ). Thirty young, healthy participants (age = 23 ± 5yrs, male/female = 15/15) performed a SLS and DVJ protocol that was recorded concurrently by the Kinect V2 and 3DMA during two sessions, one week apart. The Kinect V2 demonstrated good to excellent reliability for all SLS and DVJ variables (ICC ≥ 0.73). Concurrent validity ranged from poor to excellent (ICC = 0.02 to 0.98) during the SLS task, although trunk, hip and knee flexion and two-dimensional measures of knee abduction and frontal plane projection angle all demonstrated good to excellent validity (ICC ≥ 0.80). Concurrent validity for the DVJ task was typically worse, with only two variables exceeding ICC = 0.75 (trunk and hip flexion). These findings indicate that the Kinect V2 may have potential for large-scale screening for ACL injury risk, however future prospective research is required.  相似文献   

13.
Countermovement jump (CMJ) height is an important parameter in physical performance. This study compared CMJ height measured using ChronoJump contact mat (CJ) and Myotest accelerometer (MT) systems with a force platform (FP). Thirty recreationally active adults (32.1 ± 10.4 years, 75.9 ± 12.0 kg, 173.2 ± 6.3 cm) completed a CMJ protocol where height was simultaneously recorded using the three systems. CJ and MT measures were strongly and significant correlated (r = 0.65, 0.66, respectively; p < 0.05) with FP. CJ-derived measures were not significantly different to FP measures (p > 0.05), yet MT-derived measures were significantly different from those obtained using the FP (p < 0.05). Systematic bias was observed between FP and the CJ and between FP and MT. This study demonstrates the validity of CJ and MT systems for the assessment of CMJ height. Systematic bias and between-device differences in measurement should be considered when interpreting and comparing data from these devices.  相似文献   

14.
The purpose of the present study was to evaluate the concurrent validity and test-retest repeatability of torso-worn IMU-derived power and jump height in a counter-movement jump test. Twenty-seven healthy recreationally active males (age, 21.9 [SD 2.0] y, height, 1.76 [0.7] m, mass, 73.7 [10.3] kg) wore an IMU and completed three counter-movement jumps a week apart. A force platform and a 3D motion analysis system were used to concurrently measure the jumps and subsequently derive power and jump height (based on take-off velocity and flight time). The IMU significantly overestimated power (mean difference = 7.3 W/kg; P < 0.001) compared to force-platform-derived power but good correspondence between methods was observed (Intra-class correlation coefficient [ICC] = 0.69). IMU-derived power exhibited good reliability (ICC = 0.67). Velocity-derived jump heights exhibited poorer concurrent validity (ICC = 0.72 to 0.78) and repeatability (ICC = 0.68) than flight-time-derived jump heights, which exhibited excellent validity (ICC = 0.93 to 0.96) and reliability (ICC = 0.91). Since jump height and power are closely related, and flight-time-derived jump height exhibits excellent concurrent validity and reliability, flight-time-derived jump height could provide a more desirable measure compared to power when assessing athletic performance in a counter-movement jump with IMUs.  相似文献   

15.
ABSTRACT

A high incidence of overuse knee injuries among youth basketball players may be attributed to number of jumps. Wearable technology may be an effective tool for measuring jump load compared to traditional counting methods. The purpose of this study was to validate a commercially available jump counter (VERT® Classic) in youth basketball practices and games, and to identify the characteristics (i.e., height, direction, takeoff) of jumps recorded by the VERT® Classic. 46 (19F, 27M) youth basketball players wore a VERT® Classic and were recorded on video during games and practices. The number of jumps recorded by the VERT® Classic and evaluated by video raters were compared for each jump characteristic using intraclass correlation coefficient (ICC(3,k)), mean offset, and limits of agreement. The number and percent of VERT® Classic jumps and corresponding video jumps according to timestamp were reported. VERT® Classic jumps had excellent reliability with video-counted jumps over 15 cm (ICC(3,k) = 0.958), with a mean offset of ?2.4 jumps (fewer VERT® Classic) and limits of agreement ?12.6 to 7.8 jumps. Pairs of corresponding jumps represented 68.0% of total video jumps and 92.0% of VERT® Classic jumps. The VERT® Classic can provide an estimate of jump load in youth basketball.  相似文献   

16.
The aim of this study was to examine the content validity, construct validity and reliability of the newly developed Basketball Jump Shooting Accuracy Test (BJSAT). Basketball athletes from different playing levels (State Basketball League [SBL], n = 30, age: 22.7 ± 6.1 yr; SBL Division I, n = 11, age: 20.6 ± 2.1 yr) completed four separate trials of the BJSAT with each trial consisting of shot attempts from two- and three-point distances at pre-determined court locations. Each shot attempt was scored utilising a criteria where higher scores were given when greater accuracy was exhibited. The BJSAT detected a significant, large difference in accuracy between two- and three-point shots (d = 0.99, p < 0.01). Relative reliability across the repeated trials was rated as moderate for all athletes (intraclass correlation coefficient [ICC] = 0.71, p < 0.01) and good for the SBL athletes (ICC = 0.78, p < 0.01). Absolute reliability for all athletes was above the acceptable benchmark (coefficient of variation = 16.2%); however superior to skill tests available in the literature. In conclusion, the BJSAT is sensitive to two- and three-point shooting accuracy and can reliably assess jump shooting accuracy in basketball athletes.  相似文献   

17.
18.
Abstract

Physiological responses and performance were examined during and after a simulated trampoline competition (STC). Fifteen elite trampoline gymnasts participated, of which eight completed two routines (EX1 and EX2) and a competition final (EX3). Trampoline-specific activities were quantified by video-analysis. Countermovement jump (CMJ) and 20 maximal trampoline jump (20-MTJ) performances were assessed. Heart rate (HR) and quadriceps muscle temperature (Tm) were recorded and venous blood was drawn. A total of 252 ± 16 jumps were performed during the STC. CMJ performance declined (< 0.05) by 3.8, 5.2 and 4.2% after EX1, EX2 and EX3, respectively, and was 4.8% lower (< 0.05) than baseline 24 h post-competition. 20-MTJ flight time was ~1% shorter (< 0.05) for jump 1–10 after EX2 and 24 h post STC. Tm increased (< 0.05) to ~39°C after the warm-up, but declined (< 0.05) 1.0 and 0.6ºC before EX2 and EX3, respectively. Peak HR was 95–97% HRmax during EX1-3. Peak blood lactate, plasma K+ and NH3 were 6.5 ± 0.5, 6.0 ± 0.2 mmol · l?1 and 92 ± 10 µmol · l?1, respectively. Plasma CK increased (< 0.05) by ~50 and 65% 0 and 24 h after STC. In conclusion, a trampoline gymnastic competition includes a high number of repeated explosive and energy demanding jumps, which impairs jump performance during and 24 h post-competition.  相似文献   

19.
The current study aimed to assess the validity and test–retest reliability of a linear position transducer when compared to a force plate through a counter-movement jump in female participants. Twenty-seven female recreational athletes (19 ± 2 years) performed three counter-movement jumps simultaneously using the linear position transducer and force plate for validity. In addition, 11 elite female athletes (23 ± 6 years) performed 3 counter-movement jumps with the linear position transducer on three separate days for test–retest reliability. Pearson correlations for jump height between the devices were at a high level (= .90), with the linear position transducer overestimating jump height by 7.0 ± 2.8 cm. The reliability measured by the linear position transducer resulted in a mean intraclass correlation of .70 for jump height, .90 for peak velocity, and .91 for mean velocity. The linear position transducer was reliable for measuring counter-movement jumps in elite female athletes; however, caution should be taken for one-off jump measures as it may over-estimate jump height.  相似文献   

20.
ABSTRACT

This study compared the effects of dictating load using individual (ILVP) or group (GLVP) load-velocity profiles on lower-body strength and power. Nineteen trained males (23.6 ± 3.7 years) completed a back squat one-repetition maximum (1-RM), load-velocity profiling (LVP), and countermovement (CMJ), static-squat (SSJ) and standing-broad (SBJ) jump tests before and after 6 weeks of resistance training. Participants were randomly assigned to an ILVP, or GLVP intervention with intra-session load dictated through real-time velocity monitoring and prediction of current relative performance using either the participant’s LVP (ILVP) or a LVP based on all participant data (GLVP). Training resulted in significant increases in back squat 1-RM for the ILVP and GLVP group (p < 0.01; 9.7% and 7.2%, respectively), with no group-by-time interaction identified between training groups (p = 0.06). All jump performance significantly increased for the ILVP group (p < 0.01; CMJ: 6.6%; SSJ: 4.6%; SBJ: 6.7%), with only CMJ and SSJ improving for the GLVP group (p < 0.05; 4.3%). Despite no significant group-by-time interaction across all variables, the ILVP intervention induced a greater magnitude of adaptation when compared to a GLVP approach. Additionally, an individualised approach may lead to greater positive transfer to power-based movements, specifically vertical and horizontal jumps.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号