首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   0篇
教育   6篇
科学研究   17篇
文化理论   1篇
信息传播   2篇
  2018年   1篇
  2017年   2篇
  2016年   3篇
  2015年   3篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2007年   1篇
  2006年   1篇
  1999年   2篇
  1992年   1篇
  1991年   1篇
  1990年   1篇
  1989年   1篇
  1981年   1篇
  1979年   1篇
  1974年   1篇
排序方式: 共有26条查询结果,搜索用时 15 毫秒
21.
This retrospective study was conducted to assess the serum lipase / amylase ratio in acute pancreatitis for South Indian population attending the clinics of Gastroenterology and Emergency medicine in the last five years. One thousand one hundred and thirty two patients (768 males and 364 females) with acute pancreatitis (AP) were selected for the study. The diagnosis of AP was based on clinical evaluation, Computed Tomography (CT) findings and biochemical parameters such as serum lipase and amylase. Based on the etiology, the groups were divided into alcoholic, biliary and miscellaneous AP. Based on CT findings, groups were divided into mild, moderate and severe AP. Serum lipase, amylase and lipase / amylase ratio were calculated and statistically analyzed. Serum lipase levels in alcoholic group (3226.3 ± 1384.7) were significantly lower in comparison to biliary (6064.5 ± 1640.8) group though the levels were not significantly different from miscellaneous group (2132.3 ± 1210). Serum amylase values were significantly lower in alcoholic group (923.4 ± 557.5) in comparison to biliary (1736.2 ± 390.7) and there was significant difference between alcoholic and miscellaneous group (535.8 ± 477.6). The serum lipase / amylase ratio > 4 occurred in alcoholic group than with biliary and miscellaneous group. The sensitivity and specificity to predict alcoholic AP with lipase / amylase ratio at >4.0 was 84 % and 59 % respectively. In conclusion the serum lipase to amylase ratio greater than 3.0 could be used to differentiate but keeping the cut off at 4.0 would be of higher sensitivity without much change in specificity. The serum lipase to amylase ratio with a cut off of 3.0 or greater is not useful to differentiate the severe AP from milder AP. Hence, serum amylase and lipase are important for evaluation of pancreatitis though it is not a gold standard for the diagnosis or assessment of severity of acute pancreatitis.  相似文献   
22.
One essential approach in preserving architectural heritage is the documentation of 3D geometries and surface textures of historic buildings. For example, precise colour information, excluding lighting effects, is an intrinsic property of the surface materials of building interiors and exteriors. However, while colour information has been recorded for small sample areas, it has not been accurately documented on the scale of entire building surfaces. This is critical, because building materials decay and their colours fade with time. The goal of this project is to develop a method to assist in recording and documenting the chromatic information of interiors and exteriors of historic buildings with low cost and high efficiency. The method takes advantage of emerging high dynamic range imaging (HDRI) technology, which can store rich information about colour and illumination through digital photography. By recording the colour information, in addition to the geometry and texture information obtained through other existing technologies, we can achieve more complete documentation for architectural heritage. In this paper, we discuss an overview of the problem and present our algorithms for utilizing computer vision techniques to retrieve chromatic information of historic buildings. We also present and discuss our experiments and results of applying our method to studies of lab objects and the Hall of Supreme Harmony in the Forbidden City, Beijing.  相似文献   
23.
Charles Roetter, The Art of Psychological Warfare:1914-1945 (New York: Stein and Day, 1974–$8.95).

Benjamin Draper (ed.) Pacific Nations Broadcasting III and Bibliography (Broadcast Inudstry Conference, San Francisco State University, 1600 Holloway Ave., San Francisco, Cal. 94132—$10.00, paper)

Structures of Television by Nicholas Garnham (48 pp.)

Light Entertainment by Richard Dyer (43 pp.):

The Cultural Policy of the United Republic of Tanzania by L.A. Mbughuni (72 pp., paper, $3.30):

Cultural Policy in Hungary (79 pp., paper, $3.30):

Culturalyolicy in Liberia by Kenneth Y. Best (59 pp., paper, $2.65):

Cultural Policy in Romania by Ion Dodu Balan (70 pp., paper, $3.30):

Unesco in Perspective by Rene Maheu (129 pp., paper, $3.30):

For Books: Unesco and its Programme by Emile Delavenay (74 pp., paper, $1.00):  相似文献   
24.
This paper describes the principled design of a computational environment which depicts an animated story of the execution of programs for novice programmers. The design principles are aimed at solving the problems that novice programmers face when learning new programming languages, and are embodied in an Animated Program Tracer (APT) for Prolog. The goal of this research is to develop a more systematic, if not yet scientific, basis for the design of animated tracing tools.  相似文献   
25.
An external quality assessment was conducted for RIA of thyroid related hormones. Thirtyfive laboratories (35 for T4, 34 for T3 and 23 for TSH) from different parts of country participated in the programme. Twentyfour samples (16 pools: 5 simple and 11 manipulated pools) in 8 batches, 3 per batch per month were sent for analysis of T4, T3 and TSH. Some of the samples were repeated 3 times at different occasions to assess the imprecision of the laboratory. The overall mean percent CV obtained for T4, T3 and TSH were 22.7, 36.32 and 52.38 respectively. The recovery for added T4 was 86.73% while that for T3 was 117.4%. A large variation was obtained for recovery of TSH. For T4 estimations, 13 laboratories had a desirable performance i. e. bias less than ±10.0% and variability of bias (VB) and imprecision (IP) less than 15.0%. None of the laboratories had a desirable performance for T3 or TSH. The number of laboratories with acceptable performance i. e. bias between ±10.0–15.0%, VB and IP between 20.0–25.0% for T4, T3 and TSH were 4, 3 and 0 respectively. The number of laboratories which required attention (bias between ±15.0–20.0%; VB and IP between 20.0–25.0%) were 5,7 and 1 respectively. The unacceptable results with larger bias, VB and IP for T4, T3 and TSH were 6, 18 and 17 respectively. Our results are in general agreement that the performance of T4 assay is better than T3 and both in turn are much better than TSH. Quantitation of circulating thyroid hormones (TH) viz. tri-iodothyronine (T3), thyroxine (T4) and thyroid stimulating hormone (TSH), which form the largest percentage of hormones estimated in a clinical laboratory is mainly done by radio-immunoassay (RIA) procedures. The reliability and reproducibility of these assays are generally monitored by using internal quality control (IQC) samples in every assay batch. Thus, the IQC provides information whether the assay results are satisfactory and can be released. However, external quality assessment (EQA) is a procedure whereby an external agency undertakes evaluation of the quality of an analytical service by providing samples for analysis to individual laboratories performing the assay. The data gathered is analysed collectively. EQA therefore provides a means by which performance of a laboratory is assessed in relation to other laboratories and matching the assay unbiased by removing systematic error, if present. This is important since RIA procedure involves several steps (collection and storage of samples, quality of the reagents, procedure followed for performance of an assay, counting equipment used and the mode of the data analysis) and therefore prone to systematic errors. We therefore undertook the EQA programme for assessment of thyroid related hormones as a joint collaborative project of Bhabha Atomic Research Centre, India and International Atomic Energy Agency.  相似文献   
26.
Thyroglobulin autoantibodies (TgAb) are estimated to detect potential interferences in thyroglobulin (Tg) immunoassays and also for the diagnosis of autoimmune thyroid disease. A user friendly and robust in-house solid-phase radioassay was standardized and parameters like sensitivity, reproducibility and stability were assessed. Further, it was validated and evaluated for the detection of autoantibodies in differentiated thyroid cancer (DTC) patients. Totally 301 samples received in our laboratory for routine serum Tg estimation were studied. The samples were analyzed for TgAb by the solid-phase radioassay developed in-house and compared with commercial anti-hTg IRMA kit (Immunotech, France). The control group comprised of 37 euthyroid males from our Centre. The intra- and inter-assay CVs for the two quality control samples (Control A = 104 ± 12.6 IU/mL and Control B = 1029 ± 114 IU/mL) were found less than or equal to 6.05 and 13.85 % respectively. Solid-phase radioassay showed a good agreement on comparison with Immunotech IRMA (r = 0.99). Using the proposed cut-off thresholds (in-house solid-phase radioassay 52 IU/mL and Immunotech IRMA 30 IU/mL), 5.4 % of the control subjects were positive for TgAb by both the methods. Prevalence of TgAb in DTC patients was 17.3 and 16.6 % using the Immunotech kit and in-house solid-phase radioassay respectively. The in-house solid-phase radioassay has the requisite sensitivity for the evaluation of TgAb comparable to commercial kit and also suitable for routine use as it is rapid, user friendly and economical.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号