首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
教育   2篇
体育   1篇
  2012年   1篇
  2008年   1篇
  2007年   1篇
排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
This paper proposes an advanced substation integrated protection communication sys- tem based on the latest development in power system. The integrated protection communication system within a substation comprises a number of major components such as the merging unit, communication network and integrated protection unit. The design and capability evaluation of the communication network based on IEC61850 are focused on. Results show that huge information from 4 merging units can be transmitted real-time via adopting 100 Mbit/s optical fiber in a sub-station, and the proposed communication network is able to achieve required performance.  相似文献   
2.

Objective

This study was aimed at assessing the dynamics of vitronectin (VN), laminin (LN), and heparan sulfate/heparin (HS/HP) content changes during experimental burn healing.

Methods

VN, LN, and HS/HP were isolated and purified from normal and injured skin of domestic pigs, on the 3rd, 5th, 10th, 15th, and 21st days following thermal damage. The wounds were treated with apitherapeutic agent (propolis), silver sulfadiazine (SSD), physiological salt solution, and propolis vehicle. VN and LN were quantified using an immunoenzymatic assay and HS/HP was estimated by densitometric analysis.

Results

Propolis treatment stimulated significant increases in VN, LN, and HS/HP contents during the initial phase of study, followed by a reduction in the estimated extracellular matrix molecules. Similar patterns, although less extreme, were observed after treatment with SSD.

Conclusions

The beneficial effects of propolis on experimental wounds make it a potential apitherapeutic agent in topical burn management.  相似文献   
3.
The aim of the present study was to determine maximal oxygen uptake (VO2max) directly during uphill walking exercise and to compare these values with those achieved during running and cycling exercise. Forty untrained students (20 males and 20 females) took part in three exercise tests. The running test was performed on a horizontal treadmill and the speed was gradually increased by 0.3 m . s(-1) every 3 min. The walking test was conducted on a treadmill inclined at 12% (speed of 1.8 m . s(-1)). The load was further increased every 3 min by the addition of a mass of one-twentieth of the body mass of the participant (plastic containers filled with water and added to a backpack carried by the participant). During the bicycle ergometry test, the workload was increased by 20 W every 2 min. All tests were performed until volitional exhaustion. During all tests, oxygen uptake, minute ventilation, tidal volume, respiratory frequency, heart rate, hydrogen ion concentration, base excess, and blood lactate concentration were analysed. The Pearson correlation coefficients between the weighted walking test and the commonly applied running and bicycle ergometry tests indicate a strong association with the new test in evaluating maximal oxygen uptake. The negligible differences in VO2max between the three tests for the male participants (running: 61.0 ml . kg(-1) . min(-1); walking: 60.4 ml . kg(-1) . min(-1); cycling: 60.2 ml . kg(-1) . min(-1)), and the fact that the females achieved better results on the walking test than the cycle ergometer test (running: 45.0 ml . kg(-1) . min(-1); walking: 42.6 ml . kg(-1) . min(-1); cycling: 40.1 ml . kg(-1) . min(-1)), confirm the suitability of the new method for evaluating aerobic power. The weighted walking test could be useful in the assessment of aerobic power in individuals for whom running is not advised or is difficult. In addition, the new test allows for determination of VO2max on small treadmills with a limited speed regulator, such as those found in specialist physiotherapy and fitness centres.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号