首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
教育   2篇
体育   1篇
  2013年   1篇
  2007年   1篇
  2005年   1篇
排序方式: 共有3条查询结果,搜索用时 78 毫秒
1
1.
To analyze the use of upper limb support during paraplegic walking assisted by functional electrical stimulation ( FES). a new dynamical measurement for handle reaction vector (HRV) applied by patient to walker was proposed. To avoid the discomfort of direct monitoring, the dynamometer system was designed based on 12 string-gauge bridges instrumented on a standard walker frame. The detailed positions of these bridges were determined according to the deformation distributions of the walker frame under different directional components of HRV. To adapt the system to quantitative and reliable measurement, a redundant-optimized technique was developed in calibration. The measurement accuracy, nonlinearity, and crosstalk of the designed system were investigated, which were better than 1.01%. 2.91%. and 3. 19% respectively. Clinical trials were done with 6 paraplegic subjects using the system and one case was given as the example of actual measurement. All experiment and clinical trial results show that this method is reliable and practicable.  相似文献   
2.
Gait recognition is the key question of functional electrical stimulation (FES) system control for paraplegic walking. A new risk-tendency-graph (RTG) method was proposed to recognize the stability information in FES-assisted walking gait. The main instrument was a specialized walker dynamometer system based on a multi-channel strain-gauge bridge network fixed on the walker frame. During walking process, this system collected the reaction forces between patient's upper extremities and walker and converted them into RTG morphologic curves of dynamic gait stability in temporal and spatial domains. To demonstrate the potential usefulness of RTG, preliminary clinical trials were done with paraplegic patients. The gait stability levels of two walking cases with 4- and 12-week FES training from one subject were quantified (0.43 and 0.19) from the results of temporal and spatial RTG. Relevant instable phases in gait cycle and dangerous inclinations of patient's body during walking process were also brought forward. In conclusion, the new RTG method is practical for distinguishing more useful gait stability information for FES system control.  相似文献   
3.
Abstract

The purpose of the present study was to determine the effects of 10-in [025–m] versus 16-in [0.41-m] wheelchair handrims on cardiorespiratory and psychophysiological exercise responses during wheelchair propulsion at selected velocities. Fifteen male paraplegics (27.0 ± 5.5 yrs) performed three discontinuous exercise tests (ACE = arm crank ergometer; WERG = wheelchair roller ergometer) and two 1600-m performance-based track trials (TRACK) under simulated race conditions. There were no significant differences in HR, VO2, VE, HLa, or category-ratio ratings of perceived exertion (RPE) using different handrims during wheelchair propulsion at 4 km-h1. In contrast, at 8 km-h?1 subjects demonstrated a 13% lower steady state VO2 (p < .05) using the 10-in handrims, coincident with a 23% lower VE Steady state HR during WERG at 8 km-h?1 using the 10-in (124.4 ± 39 b.min?1) or 16-in (130.6 ± 4.6 b.min?1) handrims were not significantly different. There were also no significant differences between ACE or WERG conditions during maximal effort for VO2 or VE. However, HRpeak during ACE was 7% higher than HRpeak during WERG16 (183 ± 15 b.min?1 vs. 171 ± 12 b.min?1, p < .05), and whole blood HLa during ACE was also significantly higher (by 2.3-2.5 mmol; p < .05) compared to WERG. There were no significant differences for HR, performance time, or RPE between trials using different handrim diameters during the 1600-m event. In contrast, HLa was significantly lower using smaller handrims (9.9 mmol) compared with larger handrims (11.3 mmol), paralleling a similar difference in the laboratory. Although these data demonstrated few significant differences of physiologic responses between trials using different handrims, there was a tendency for a lower metabolic stress using the smaller handrims.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号