首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
体育   13篇
  2019年   3篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2013年   7篇
排序方式: 共有13条查询结果,搜索用时 46 毫秒
1.
Abstract

The aim of this study was to assess the capability of the 3dNX? accelerometer to predict energy expenditure in two separate, free-living cohorts. Twenty-three adolescents and 14 young adults took a single dose of doubly labelled water and wore a 3dNX? activity monitor during waking hours for a 10-day period while carrying out their normal routines. Multiple linear regression with backward elimination was used to establish the strength of the associations between various indices of energy expenditure, physical activity counts, and anthropometric variables. 3dNX? output accounted for 27% and 35% of the variance in the total energy expenditure of the adolescent and young adult cohort, respectively. The explained variance increased to 78%, with a standard error of estimate of 7%, when 3dNX? output was combined with body composition variables. The 3dNX? accelerometer can be used to predict free-living daily energy expenditure with a standard error of estimate of 1.65 MJ in adolescents and 1.52 MJ in young adults. The inclusion of anthropometric variables reduces the error to approximately 1 MJ. Although it remains to cross-validate these models in other populations, early indications suggest that the 3dNX? provides a useful method of predicting energy expenditure in free-living individuals.  相似文献   
2.
Detection of neuro-muscular fatigue in strength training is difficult, due to missing criterion measures and the complexity of fatigue. Thus, a variety of methods are used to determine fatigue. The aim of this study was to use a principal component analysis (PCA) on a multifactorial data-set based on kinematic measurements to determine fatigue. Twenty participants (strength training experienced, 60% male) executed 3 sets of 3 exercises with 50 (12 repetitions), 75 (12 repetitions) and 100%-12 RM (RM). Data were collected with a 3D accelerometer and analysed by a newly developed algorithm to evaluate parameters for each repetition. A PCA with six variables was carried out on the results. A fatigue factor was computed based on the loadings on the first component. One-way ANOVA with Bonferroni post hoc analysis was calculated to test for differences between the intensity levels. All six input variables had high loadings on the first component. The ANOVA showed a significant difference between intensities (p < 0.001). Post-hoc analysis revealed a difference between 100% and the lower intensities (p < 0.05) and no difference between 50 and 75%-12RM. Based on these results, it is possible to distinguish between fatigued and non-fatigued sets of strength training.  相似文献   
3.
This study analysed the validity and reliability of a new optoelectronic device (Velowin) for the measurement of vertical displacement and velocity as well as to estimate force and mechanical power. Eleven trained males with Mean (SD) age = 27.4 (4.8) years, completed an incremental squat exercise test with 5 different loads (<30–90% of their 1?repetition maximum) while displacement and vertical velocity of the barbell were simultaneously measured using an integrated 3D system (3D motion capture system + force platform) and Velowin. Substantial to almost perfect correlation (concordance correlation coefficient = 0.75–0.96), root mean square error as coefficient of variation ±90% confidence interval ≤10% and good to excellent intraclass correlation coefficient = 0.84–0.99 were determined for all the variables. Passing and Bablock regression methods revealed no differences for average velocity. However, significant but consistent bias were determined for average or peak force and power while systematic and not proportional bias was found for displacement. In conclusion, Velowin, in holds of some potential advantages over traditionally used accelerometer or linear transducers, represents a valid and reliable alternative to monitor vertical displacement and velocity as well as to estimate average force and mechanical power during the squat exercise.  相似文献   
4.
Abstract

Maximum oxygen uptake ([Vdot]O2PEAK) is generally considered to be the best single marker for aerobic fitness. While a positive relationship between daily physical activity and aerobic fitness has been established in adults, the relationship appears less clear in children and adolescents. The purpose of this paper is to summarise recently published data on the relationship between daily physical activity, as measured by accelerometers, and [Vdot]O2PEAK in children and adolescents. A PubMed search was performed on 29 October 2010 to identify relevant articles. Studies were considered relevant if they included measurement of daily physical activity by accelerometry and related to a [Vdot]O2PEAK either measured directly at a maximal exercise test or estimated from maximal power output. A total of nine studies were identified, with a total number of 6116 children and adolescents investigated. Most studies reported a low-to-moderate relationship (r = 0.10–0.45) between objectively measured daily physical activity and [Vdot]O2PEAK. No conclusive evidence exists that physical activity of higher intensities are more closely related to [Vdot]O2PEAK, than lower intensities.  相似文献   
5.
Abstract

There has been no previous investigation of the concurrent validity and reliability of the current 5 Hz global positioning system (GPS) to assess sprinting speed or the reliability of integrated GPS–accelerometer technology. In the present study, we wished to determine: (1) the concurrent validity and reliability of a GPS and timing gates to measure sprinting speed or distance, and (2) the reliability of proper accelerations recorded via GPS–accelerometer integration. Nineteen elite youth rugby league players performed two over-ground sprints and were simultaneously assessed using GPS and timing gates. The GPS measurements systematically underestimated both distance and timing gate speed. The GPS measurements were reliable for all variables of distance and speed (coefficient of variation [CV] = 1.62% to 2.3%), particularly peak speed (95% limits of agreement [LOA] = 0.00 ± 0.8 km · h?1; CV = 0.78%). Timing gates were more reliable (CV = 1% to 1.54%) than equivalent GPS measurements. Accelerometer measurements were least reliable (CV = 4.69% to 5.16%), particularly for the frequency of proper accelerations (95% LOA = 1.00 ± 5.43; CV = 14.12%). Timing gates and GPS were found to reliably assess speed and distance, although the validity of the GPS remains questionable. The error found in accelerometer measurements indicates the limits of this device for detecting changes in performance.  相似文献   
6.

Purpose: To describe the development and preliminary evaluation of the Multicontext Sitting Time Questionnaire (MSTQ). Method: During development of the MSTQ, contexts and domains of sitting behavior were utilized as recall cues to improve the accuracy of sitting assessment. The terms “workday” and “nonworkday” were used to disambiguate occupational and discretionary sitting. An expert panel evaluated content validity. Among 25 participants, test–retest reliability of the MSTQ items was assessed with intraclass correlation coefficients (ICCs). Convergent validity was assessed versus relative and absolute accelerometer-estimated sedentary time and activity log using Pearson (r) or Spearman (ρ) correlation coefficients where appropriate. Results: Pilot testing revealed Web-based MSTQ administration was rapid, scalable, and inexpensive. Most items in the MSTQ demonstrated acceptable reliability (ICCs>.70). Compared with accelerometer-estimated sedentary time relative to total wear time, the MSTQ exhibited a low correlation on workdays (r = .34) and a moderately high correlation on nonworkdays (r = .61). Conclusions: The systematic development of the MSTQ resulted in several improvements over previous tools and may serve as a model for purpose-driven questionnaire design. Additional validation is needed to conclusively determine the utility of the MSTQ.  相似文献   
7.
Abstract

The purpose of this study was to analyse the associations between sports participation, levels of moderate to vigorous physical activity (MVPA) and cardiorespiratory fitness (CRF). The study comprised 310 participants (183 girls and 127 boys) aged 11–18 years. Sports participation was assessed by questionnaire and habitual physical activity (PA) was measured objectively with accelerometers. The 20-m shuttle-run test was used to estimate CRF. Logistic regression analyses were carried out with CRF as the outcome. The odds ratio (OR) for being fit was greater for those who comply with 60 min · day?1 in MVPA (OR = 2.612; 95%confidence interval [CI] = 1.614–4.225) in comparison with those who do not. Participation in competitive sports at club levels increased the chances of being fit (OR = 13.483; 95%CI = 4.560–39.864), independently of MVPA levels. There were positive and significant trends in CRF and objectively measured PA across the levels of engagement in competitive sports (P < 0.05). Concluding, participation in competitive sports at club level is more effective than other organised or non-organised sports to reach healthier levels of CRF and recommend levels of MVPA.  相似文献   
8.
An appropriated level of motor competence is essential for children´s healthy growth and development and a key factor in the promotion of lifelong active lifestyles and health.

The purpose of this study was to examine associations between motor competence and different physical activity intensities (light, moderate, moderate-to-vigorous and vigorous physical activity), as well as total physical activity, over a two-year period, in adolescents. The sample comprised of 103 adolescents (13.49 ± 0.87 years, 53 girls), from the north of Portugal. Motor competence was evaluated with the body coordination test, Körperkoordination-Test-für-Kinder. Physical activity was objectively assessed with GT1M accelerometers (ActiGraph, Pensacola, FL, USA). Physical activity variables were expressed as proportions of accelerometer wear time. Regression analyses showed positive longitudinal associations between motor competence at baseline and moderate physical activity (B = 0.0033, p = 0.018), moderate-to-vigorous physical activity (B = 0.0052, p = 0.024) and total physical activity (B = 0.067, p = 0.040) at follow up, after adjustments for age, sex, the corresponding physical activity intensity at baseline, body mass index, pubertal stage and socioeconomic status. Our ?ndings highlight the importance of motor competence development to promote moderate-to-vigorous physical activity during adolescence.  相似文献   

9.
This study examined the validity of the Actical accelerometer step count and energy expenditure (EE) functions in healthy young adults. Forty-three participants participated in study 1. Actical step counts were compared to actual steps taken during a 200 m walk around an indoor track at self-selected pace and during treadmill walking at different speeds (0.894, 1.56 and 2.01 m · s–1) for 5 min. The Actical was also compared to three pedometers. For study 2, 15 participants from study 1 walked on a treadmill at their predetermined self-selected pace for 15 min. Actical EE was compared to EE measured by indirect calorimetry. One-way analysis of variance and t-tests were used to examine differences. There were no statistical difference between Actical steps and actual steps in self-selected pace walking and during treadmill walking at moderate and fast speeds. During treadmill walking at slow speed, the Actical step counts significantly under predicted actual steps taken. For study 2, there was no statistical difference between measured EE and Actical-recorded EE. The Actical provides valid estimates of step counts at self-selected pace and walking at constant speeds of 1.56 and 2.01 m · s–1. The Actical underestimates EE of walking at constants speeds ≥1.38 m · s–1.  相似文献   
10.
Where as video cameras are a reliable and established technology for the measurement of kinematic parameters, accelerometers are increasingly being employed for this type of measurement due to their ease of use, performance, and comparatively low cost. However, the majority of accelerometer-based studies involve a single channel due to the difficulty associated with synchronizing multiple accelerometer channels. The authors of this article outline a method to synchronize multiple accelerometers using a maxima detection method. Results are presented that demonstrate the effectiveness of the new synchronization method with 52 of 54 recorded data sets showing no time lag error and two tests showing an error of .04 sec. Inter-instrument and instrument-video correlations are all greater than r = .94 (p < .01), with inter-instrument precision (Root Mean Square Error; RMSE) ≈ .1ms?2, demonstrating the efficacy of the technique. In conclusion, the new technique offers a robust solution, giving further support to the movement toward wider adoption of accelerometer-based performance measurement systems in sports science.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号