首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Soft Switched Synchronous Rectifier with Phase-Shifted Full Bridge Converter and Its Small-Signal Analysis
作者姓名:潘三博  潘俊民  万健如
作者单位:[1]School of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200030, China [2]School of Electrical Engineerir and Automation, Tianjin University, Tianjin 300072, China
摘    要:BY USING THE OUTPUT INDUCTORS AND BODY CAPACITANCES WITHOUT ADDING ANY COMPONENT COMPARED WITH HARD SWITCHING SYNCHRONOUS RECTIFIER,THE TOPOLOGY OF A SOFT SWITCHED SYNCHRONOUS RECTIFIER WITH PHASE-SHIFTED FULL BRIDGE ZERO VOLTAGE SWITCHING DC/DC CONVERTER IS PROPOSED. THE CONVERTER EFFICIENCY IS MAXIMIZED DUE TO SOFT SWITCHING OF THE FULL BRIDGE MOSFETS AND THE SYNCHRONOUS MOS-FETS, AND ALSO THE LOW CONDUCTION LOSS OF SYNCHRONOUS MOSFET. THE OPERATION PRINCIPLES OF THE CIRCUIT ARE ANALYZED IN DETAIL AND THE SMALL-SIGNAL MODEL IS DERIVED, ALSO THE CONVERTER DYNAMIC CHARACTERISTICS ARE ANALYZED. FREQUENCY RESPONSES OF TRANSFER FUNCTIONS UNDER DIFFERENT VALUES OF TRANSFORMER PRIMARY LEAKAGE INDUCTANCE ARE DISCUSSED. THE EXPERIMENTAL RESULTS WERE OBTAINED FROM A 400 V INPUT AND 100 A/12 V OUTPUT DC/DC CONVERTER OPERATING AT 100 KHZ. THE RESULTS SHOW THAT THE CONVERTER EFFICIENCY IS 2% HIGHER IN RATED POWER THAN TRADITIONAL DIODE RECTIFIER.

关 键 词:软交换同步整流器  相位移全桥  零电压开关  小信号分析  DC/DC
收稿时间:2005-08-15

Soft Switched Synchronous Rectifier with Phase-Shifted Full Bridge Converter and Its Small-Signal Analysis
PAN Sanbo,PAN Junmin,WAN Jianru.Soft Switched Synchronous Rectifier with Phase-Shifted Full Bridge Converter and Its Small-Signal Analysis[J].Transactions of Tianjin University,2006,12(1):6-12.
Authors:PAN Sanbo  PAN Junmin  WAN Jianru
Abstract:By using the output inductors and body capacitances without adding any component compared with hard switching synchronous rectifier,the topology of a soft switched synchronous rectifier with phase-shifted full bridge zero voltage switching DC/DC converter is proposed. The converter efficiency is maximized due to soft switching of the full bridge MOSFETs and the synchronous MOSFETs, and also the low conduction loss of synchronous MOSFET. The operation principles of the circuit are analyzed in detail and the small-signal model is derived, also the converter dynamic characteristics are analyzed. Frequency responses of transfer functions under different values of transformer primary leakage inductance are discussed. The experimental results were obtained from a 400 V input and 100 A/12 V output DC/DC converter operating at 100 kHz. The results show that the converter efficiency is 2% higher in rated power than traditional diode rectifier.
Keywords:phase-shifted full bridge  zero voltage switch  synchronous rectifier  DC/DC  small signal
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号