首页 | 本学科首页   官方微博 | 高级检索  
     检索      

定量掩蔽对测钙准确度影响的研究
引用本文:张新爱,张秀华.定量掩蔽对测钙准确度影响的研究[J].洛阳工业高等专科学校学报,2002,12(4):34-35.
作者姓名:张新爱  张秀华
作者单位:洛阳工业高等专科学校,材料工程系,河南,洛阳,471003
摘    要:在铁、铝、钙、镁、硅共存的情况下测定钙,共存组分铁、铝、镁、硅都将干扰钙的测定。根据硅、铁、铝等干扰组分与掩蔽剂反应的比例关系,分析计算出掩蔽剂的适宜加入量。实验结果表明,对干扰组分定量掩蔽,可提高测钙的准确度。

关 键 词:钙的测定  准确度  定量掩蔽
文章编号:1008-8814(2002)04-0034-02
修稿时间:2002年7月5日

Study on the Ration of Masking Agent Influencing the Determining Accuracy of Calcium
ZHANG Xin-ai,ZHANG Xiu-hua.Study on the Ration of Masking Agent Influencing the Determining Accuracy of Calcium[J].Journal of Luoyang Technology College,2002,12(4):34-35.
Authors:ZHANG Xin-ai  ZHANG Xiu-hua
Abstract:In silicate analysis, the determining accuracy of calcium was disturbed by the content of Fe, Al, Mg and Si. For resolving it, the proportion relation of masking agent and interfering substance (Fe, Al, Mg and Si) was analyzed, and the suitable content of masking agent was brought up also. By experimental verification, it has been found that the determining accuracy of calcium was improved by quantifying the content of masking agent.
Keywords:
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号