Sensitivity analyses of cables to suspen-dome structural system |
| |
Authors: | Email author" target="_blank">Gao?Bo-qing?Email author Weng?En-hao |
| |
Institution: | (1) Department of Civil Engineering, Zhejiang University, 310027 Hangzhou, China |
| |
Abstract: | The construction of the cables is a key step for erecting suspen-dome structures. In practical engineering, it is difficult to ensure that the designed pre-stresses of cables have been exactly introduced into the structures in the site; so it is necessary to evaluate the influence of the variation of the pre-stresses on the structural behavior. In the present work, an orthogonal design method was employed to investigate the pre-stressed cables'sensitivity to the suspen-dome system. The investigation was concentrated on a Kiewitt suspen-dome. Parametric studies were carried out to study the sensitivity of the structure's static behavior, dynamic behavior, and buckling loads when the pre-stresses in the cables varied. The investigation indicated that suspen-dome structures are sensitive to the pre-stresses in all cables; and that the sensitivity depended on the location of the cables and the kind of structural behavior. Useful suggestions are given at the end of the paper. |
| |
Keywords: | Suspen-dome Orthogonal design method Cable Sensitivity analysis |
本文献已被 万方数据 SpringerLink 等数据库收录! |