首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Structural testing of Historical Heritage Site Towers by microwave remote sensing
Institution:1. Department of Civil and Environmental Engineering, University of Perugia, Via G. Duranti 93, 06125 Perugia, Italy;2. CIRIAF Interuniversity Research Center on Pollution and Environment “M. Felli”, University of Perugia, Via G. Duranti, 06125 Perugia, Italy;3. Department of Engineering, University of Perugia, Via G. Duranti 1/A4, 06125 Perugia, Italy;1. Department of Mechanical Engineering, Dynamic Research Group, University of Sheffield, Sheffield, UK;2. Department of Architecture, Built environment and Construction engineering (DABC), Politecnico di Milano, Milan, Italy;1. Universitat Politècnica de València, Valencia, Spain;2. Università degli Studi di Firenze, Firenze, Italy;3. Università Politecnica delle Marche, Ancona, Italy;4. University of Alicante, Alicante, Spain;1. Politecnico di Milano, Department of Architecture, Built environment and Construction engineering (ABC), Milan, Italy;2. Politecnico di Milano, Milan, Italy
Abstract:Radar equipment based on microwave interferometry has been employed to remotely survey the dynamic behaviour of the celebrated and historical towers of Florence, Italy. The measurement technique demonstrated in this paper results both as sensitive and accurate as the conventional technique, which is based on contact accelerometers, plus allows simple and rapid monitoring of structures even at great distances.