首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Analysis of superheater’s pipe wall overtemperature by fault tree diagnose
Authors:Sheng De-ren  Ren Hao-ren  Chen Jian-hong  Li Wei
Institution:(1) Institute of Power Plant Thermal Energy Engineering & Automation, Zhejiang University, 310027 Hangzhou, China
Abstract:After research on a 2000t/h subcritical forced-circulation balanced ventilation were applied boiler and the structure and operation of its auxiliary system builds up this heat transfer model of a superheater’s pipe wall and analyze the effect of primary factors on the overtemperature of the pipe wall. Fault tree structure was used to uncover the multiplayer logic between the overtemperature of the superheater’s pipe wall and the faults.
Keywords:Fault tree  Superheater  Overtemperature  Diagnose analyze
本文献已被 SpringerLink 等数据库收录!