首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Non-destructive monitoring methods as indicators of damage cause on Cathedral of St. Lawrence in Trogir,Croatia
Institution:1. MTA-PTE High Intensity THz Research Group, Ifjúság útja 6, 7624 Pécs, Hungary;2. University of Pécs, Institute of Physics, Ifjúság útja 6, 7624 Pécs, Hungary;3. Budapest University of Technology, Economics Department of Construction Materials and Engineering Geology, M?egyetem rkp. 3, H-1111 Budapest, Hungary;4. Institute of Electronic Structure and Laser (IESL), Foundation for Research and Technology-Hellas (FORTH), P.O. Box 1385, Heraklion, Crete 71110, Greece;1. LUNAM université du Maine, CNRS UMR 6613, laboratoire d’acoustique de l’université du Maine, avenue Olivier-Messiaen, 72085 Le Mans cedex 9, France;2. DCPCR, Musée du Louvre, Pavillon Mollien, 75058 Paris, France;1. Department of Engineering for Innovation, University of Salento, Monteroni di Lecce, 73047 Lecce, Italy;2. Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Monteroni di Lecce, 73047 Lecce, Italy;1. Department of Biology, University of Florence, Via Madonna del Piano 6, 50019 Sesto Fiorentino, Florence, Italy;2. University of Florida. Soil and Water Science Department, CGRB building 2033 Mowry Road, Gainesville, FL 32610-3610, USA;3. Institute for the Conservation and Promotion of Cultural Heritage - ICVBC-CNR, 50019 Sesto Fiorentino, Florence, Italy;4. Department of Crystallography Mineralogy and Mineral Deposits, University of Barcelona, Barcelona, Spain;1. Instituto de Investigaciones en Materiales, Departamento de Materiales Metálicos y Cerámicos, Universidad Nacional Autónoma de México, Circuito exterior s/n, Ciudad Universitaria, Delegación Coyoacán, CP 04510, Mexico;2. Universidad Autónoma Metropolitana-Unidad Iztapalapa, Departamento de Química, San Rafael Atlixco No. 186, Col. Vicentina, Iztapalapa, CP 09340, Mexico
Abstract:Durability is one of the most important engineering properties of cultural heritage monuments. For the purpose of the preservation of structures for future generations, the causes of damage should be determined for the proper choice of type and location of strengthening. The condition of the foundation is difficult to determine without an extensive investigation which is critical because most often the cause of damage is found in such foundations. Geotechnical investigation techniques require the damage and destruction of a building's surroundings or the damage of a foundation with a boring device. Non-destructive methods, such as geophysical methods, are less reliable and the results of such investigations must be combined with the results of subsurface exploration. This paper is a presentation of results achieved through the monitoring of the activity of a number of joints on the Cathedral of St. Lawrence in Trogir, Croatia, which is a cultural heritage monument protected by UNESCO. Excavations for the purpose of flagging replacement in the zone around the east frontage were made in 1979. A probe beneath the main apse uncovered a water cistern where the connection between the mid and north apses is located, and instead of a staggered foundation, a wall with a depth of more than 2.2 m beneath the flagging was discovered. With respect to the given that churches were built on existing ones, it is possible to assume that this is a wall of the late-antiquity church described by Constantin Porfirogenet in the 10th century, built on and later adapted to the foundation for the new structure. The displacement in time of the construction elements of the cathedral were measured and recorded using non-destructive methods. Fissure displacement behaviour, air temperature and air humidity were monitored. The monitoring of the air humidity did not lead to any useful conclusion, so it was quickly dismissed. Observations of data were performed during two periods with an interruption between the two caused by insufficient monetary resources. Data from almost 8 years of continuous measuring are available. The aim of this paper is to present the data of the measured fissure displacements which were correlated with air temperature changes and mathematical models which were based on statistical analysis. Correlation coefficients show that the analysed fissures react to the air temperature changes with different intensities. The obtained data lead to the conclusion that the causes of the structural damage are not found within a displacement or failure of the foundations. Instead, the causes of the damage were found in other parts of the structure.
Keywords:Cultural heritage  Monitoring  Non-destructive methods  Fissure  Temperature
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号