Thermal analyses of combined utilization process of seawater by solar chimney
Authors:Yiping Wang  Zhenlei Fang  Li Zhu
Institution:1. School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China;School of Architecture, Tianjin University, Tianjin 300072, China
2. School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China
3. School of Architecture, Tianjin University, Tianjin 300072, China
Abstract:It is promising to simultaneously develop multiple products through the combined utilization of sea-water by solar chimney technology. A small scale experimental system was set up. The collector temperature, the seawater temperature, and the temperature and humidity of the airflow under the collector were measured. Thermal network analysis of the system was carried out. The results show that the airflow is nearly saturated at the entrance of the chimney, and the mean dry-bulb and wet-bulb temperatures of the airflow have increased by 8.4℃ and 9.6℃ respectively. The radiation heat transfer between the collector and the sky is the biggest heat loss in the system, which is up to 29.1% on average of the solar energy. However, the water evaporation heat is about 23.6% on average of the solar energy. To reduce the heat loss and enhance the water evaporation, it is necessary to reduce the emissivity and thermal conductivity of the collector and increase the evaporation areas.
Keywords:solar chimney  combined utilization of seawater  thermal network  enhanced evaporation