Determination of reference interval for presepsin,an early marker for sepsis
Authors:Davide Giavarina  Mariarosa Carta
Institution:Clinical Chemistry and Haematology Laboratory, San Bortolo Hospital, Vicenza, Italy
Abstract:

Introduction

Presepsin, the circulating soluble form of CD14 subtype (sCD14-ST) is a new emerging early marker for sepsis. Various cutoff levels of presepsin have been proposed, to discriminate between systemic bacterial and nonbacterial infectious diseases. The aim of this work was to define the reference interval for presepsin according to the CLSI C28-A3c approved guideline.

Materials and methods

Reference individuals (N = 200; 120 females) aged 18-75 years (median 39 years), free from inflammatory diseases, were selected for the study. Presepsin concentrations were measured by a commercially available chemiluminescent enzyme immunoassay (PATHFASTTM, Mitsubishi Chemical Europe GmbH, Düsseldorf, Germany). Reference limits were calculated using the non-parametric percentile method.

Results

Overall, the reference limits for the presepsin were 55–184 pg/mL (90% confidence intervals, CI, were 45 to 58 and 161 to 214, respectively). There were no significant differences between males and females and the presepsin concentrations were not even particularly influenced by age. The upper reference limit for the presepsin is much lower than every cut-off limit so far proposed, both for sepsis and also for systemic inflammatory response syndrome.

Conclusion

Specific decision levels are required to define the diagnostic and prognostic roles of presepsin in different settings of inflammatory and infectious diseases. Reference values can help to distinguish and quickly rule out healthy subjects or patients with other pathologies.Key words: CD14 Antigen, presepsin, reference values, male, female, Clinical and Laboratory Standard Institute