Numerical study on effects of door-opening on airflow patterns and dynamic cross-contamination in an ISO class 5 operating room
Authors:Shuyun Dong  Guangbei Tu  Rongguang Cao  Zhenfeng Yu
Institution:1. School of Environmental Science and Engineering,Tianjin University,Tianjin 300072,China
2. Beijing Building Construction Research Institute,Beijing 100039,China
3. Hong Kong Hua Yi Designing Consultants (Shenzhen) Co.,Ltd.,Shenzhen 518031,China
Abstract:The contamination diffusion to the operating room when the door is open was simulated with a computational fluid dynamic (CFD) method,to give the extent of the contamination diffusion.The influence of the door-opening procedure was ignored since the door of the operating room is normally a sliding one.The flow field in the case of the 16 s course of opening the door was simulated.The simulated and the experimental results demonstrate that the extent of the contamination diffusion is around 1.5 m when there is no temperature difference between indoor and outdoor,and there is hardly any contamination diffusion when the temperature difference is 1 ℃.It can be concluded that the positive pressure difference in the operating room lost its function in preventing the contamination when the door is open.That the temperature of corridor is lower than that of operating room contributes to contamination control.Keeping 1 ℃ temperature difference between corridor and operating room and increasing positive pressure and air flow are suggested.It is more secure to set up an anteroom if persons come in or out of the operation room at the course of surgery.
Keywords:contamination control  computational fluid dynamic method  operating room  door-opening  biological clean operating room
本文献已被 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号