首页 | 本学科首页   官方微博 | 高级检索  
     检索      

凝固点降低法测定摩尔质量实验装置的改进
引用本文:王保玉,韩民乐,李云平,李森兰.凝固点降低法测定摩尔质量实验装置的改进[J].洛阳师范学院学报,2009,28(2):148-149.
作者姓名:王保玉  韩民乐  李云平  李森兰
作者单位:洛阳师范学院化学化工学院,河南洛阳,471022
摘    要:对凝固点降低法测定摩尔质量的实验装置进行了改进.实验结果表明,改进后的装置操作方便,所得结果准确、重现性好.以环己烷作溶剂、萘为溶质测得萘摩尔质量的相对误差均在1%以内.

关 键 词:凝固点降低  摩尔质量  实验装置  环己烷  

Improvement of the Experiment Device of Measuring Molar Mass by Freezing Point Depression Method
WANG Bao-yu,HAN Min-le,LI Yun-ping,LI Sen-lan.Improvement of the Experiment Device of Measuring Molar Mass by Freezing Point Depression Method[J].Journal of Luoyang Teachers College,2009,28(2):148-149.
Authors:WANG Bao-yu  HAN Min-le  LI Yun-ping  LI Sen-lan
Institution:College of Chemistry and Chemical Engineering;Luoyang Normal University;Luoyang 471022;China
Abstract:A device for measuring molarmass by freezing point depression method was improved. The results showed that the improved device is easy to operate, the experiment results is precise and could reappear. With the hexamethylene as solvent and naphthalene as solute, the relative error of molar mass of naphthalene measured is not much as 1%.
Keywords:freezing point depression  molarmass  experimental device  hexamethylene  naphthalene  