作者单位:新疆医科大学药学院;
摘    要:在pH为6-7范围内,用分光光度法测定不同水样中微量元素铜(Ⅱ)的含量。Cu(Ⅱ)与二苯碳酰二肼生成红色配合物,最大吸收波长为545nm,表观摩尔吸光系数为ε=1.297×10^4L·mol^-1·cm^-1,Cu(Ⅱ)含量在测定范围内服从朗伯比耳定律,测定结果的相对标准偏差RSD=2.86%(n=7),回收率试验结果在98-102%之间。用于水样中微量铜的测定,结果满意。

关 键 词:微量元素铜(Ⅱ)  分光光度法  水样

Spectrophotometer Analysis of Trace Element Cu(Ⅱ)
YAN Chao.Spectrophotometer Analysis of Trace Element Cu(Ⅱ)[J].Journal of Jinzhu University of Guiyang,2009(3):53-54.
Authors:YAN Chao
Institution:YAN Chao (College of Pharmacy,Xinjiang Medical University,Urumqi Xinjiang 830011,China)
Abstract:Spectrophotometer is used to test the different water samples Copper(Ⅱ) content in the pH range 6-7. Cu(Ⅱ) and diphenylcarbazide hydrazine form a red complex with its molar. Absorption maximal of the complex are found at the wavelength of 545 nm and its apparent molar absorptive is ε=1.297×10^4L·mol^-1·cm^-1. The Copper(Ⅱ)content in the context fits the Lambert's law, and RSD=2.86%(n=7) values calculated from the analytical results and values of recovery found were in the range of 94% to 101%. Satisfactory result is obtained for determination of microa-mounts copper in water.
Keywords:copper(Ⅱ)  spectrophotometer  different sources of water