首页 | 本学科首页   官方微博 | 高级检索  
     检索      

微型钢管外表面温度场可视化实验研究
引用本文:刘志刚,徐建中,赵耀华.微型钢管外表面温度场可视化实验研究[J].中国科学院研究生院学报,2006,23(3):317-322.
作者姓名:刘志刚  徐建中  赵耀华
作者单位:1. 中国科学院工程热物理研究所,北京,100080
2. 浙江大学工程训练中心,杭州,310058
摘    要:为了准确测量微管外表面温度场的分布,并解决沿微管轴向导热对微管内部对流换热的影响,本文首次把非接触式测量温度方法引入到微尺度实验中。本次研究搭建了能够进行气体、液体流动与换热的微流动实验台,用蒸馏水作为工质,采用红外成像仪加专用红外放大镜头对微型钢管表面温度场作了可视化实验研究,得到了在Re数不变时,不同加热功率下内直径为168µm和外直径为406µm微型钢管外表面温度场的分布图,进而能得到了沿轴向温度对沿轴向长度的二次导数。建立简化的数学模型,并通过推导获得了沿轴向的导热对内部对流换热的关系式。实验与理论推导结果表明,在微圆管单相流情况下,其轴向的导热对管内对流换热影响很小,可以忽略不计。

关 键 词:微尺度传热  微流动  微管  红外成像仪
文章编号:1002-1175(2006)03-0317-06
修稿时间:2005年5月17日

A Visual Experimental Study on Surface Temperature Field in Stainless Steel Microtube
LIU Zhi-Gang,XU Jian-Zhong,ZHAO Yao-Hua.A Visual Experimental Study on Surface Temperature Field in Stainless Steel Microtube[J].Journal of the Graduate School of the Chinese Academy of Sciences,2006,23(3):317-322.
Authors:LIU Zhi-Gang  XU Jian-Zhong  ZHAO Yao-Hua
Institution:Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100080, China
Abstract:To accurately measure the surface temperature field of the microtube and solve the influence of axial heat conduction along wall of the microtube on convective heat transfer in the microtube, No-contacting temperature measuring method is firstly used in the microscale experiment. An experimental test loop, which can conduct some tests about micro-heat transfer and micro-flow for gas and liquid, is established. When distilled water is used as the working fluid and flowing through the microtube, a visual experiment about the surface temperature field is conducted, that is, the surface temperature field photos of microtube with inner diameter of 168µm and outer diameter of 406µm were acquired by employing the infrared thermoviewer and specially magnifying lens for the constant Re number and different heating powers. Further, the second order derivative about the temperature along axial microtube to the length is obtained. A simple mathematic model is set up and the correlation between the axially conductive heat and inner convective heat transfer is obtained by derivation. The experimental results and the theoretical analysis show that the quantity of axial heat conduction is considerable small and may be neglected compared to the convective heat transfer in the condition of single-phase.
Keywords:micro-transfer heat  micro-flow  microtube  infrared thermoviewer
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国科学院研究生院学报》浏览原始摘要信息
点击此处可从《中国科学院研究生院学报》下载免费的PDF全文