Seismic performance evaluation of steel frame-steel plate shear walls system based on the capacity spectrum method
Authors:Jian-hua Shao  Qiang Gu  Yong-kang Shen
Institution:(1) College of Civil Engineering, Hohai University, Nanjing, 210098, China;(2) Department of Civil Engineering, Suzhou University of Science and Technology, Suzhou, 215011, China
Abstract:This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the base shear force-roof displacement curve of structure is converted to the capacity spectrum of an equivalent single-degree-of-freedom (SDOF) system. The capacity spectrum method (CSM) is programmed by means of MATLAB7.0 computer language. A dual lateral force resisting system of 10-story steel flame-steel plate shear walls (SPSW) is designed according to the corresponding China design codes. The base shear force-roof displacement curve of structure subjected to the monotonic increasing lateral inverse triangular load is obtained by applying the equivalent strip model to stimulate SPSW and by using the finite element analysis software SAP2000 to make Pushover analysis. The seismic performance of this dual system subjected to three different conditions, i.e. the 8-intensity frequently occurred earthquake, fortification earthquake and seldom occurred earthquake, is evaluated by CSM program. The excessive safety of steel flame-SPSW system designed according to the present China design codes is pointed out and a new design method is suggested.
Keywords:Steel flame-steel plate shear walls (SPSW) system  Capacity spectrum method (CSM)  Seismic demand spectrum  Base shear force-roof displacement  Seismic performance evaluation
本文献已被 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号