首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Application of short-time Fourier transform to high-rise frame structural-health monitoring based on change of inherent frequency over time
Authors:GUO Shao-xia and PEI Qiang
Institution:The R&D Center of Civil Engineering Technology, Dalian University, Dalian 116622, P. R. China and The R&D Center of Civil Engineering Technology, Dalian University, Dalian 116622, P. R. China
Abstract:The high-rise frame structure has become more and more widespread, like its damage from the complication of the environment. The traditional method of damage detection, which is only suitable for the stationary signal, does not apply to a high-rise frame structure because its damage signal is non-stationary. Thus, this paper presents an application of the short-time Fourier transform (STFT) to damage detection of high-rise frame structures. Compared with the fast Fourier transform, STFT is found to be able to express the frequency spectrum property of the time interval using the signal within this interval. Application of STFT to analyzing a Matlab model and the shaking table test with a twelve-story frame-structure model reveals that there is a positive correlation between the slope of the frequency versus time and the damage level. If the slope is equal to or greater than zero, the structure is not damaged. If the slope is smaller than zero, the structure is damaged, and the less the slope is, the more serious the damage is. The damage results from calculation based on the Matlab model are consistent with those from the shaking table test, demonstrating that STFT can be a reliable tool for the damage detection of high-rise frame structures.
Keywords:short-time Fourier transform  fast Fourier transform  damage identification  shaking table test  time-frequency analysis
本文献已被 CNKI 等数据库收录!
点击此处可从《重庆大学学报(英文版)》浏览原始摘要信息
点击此处可从《重庆大学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号