首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Removal of aqueous phenol compound by vacuum membrane distillation
作者姓名:LIU Zuohu  LIU Renlong  DU Jun  TAO Changyuan  LI Xiaohong College of Chemistry & Chemical Engineering  Chongqing University  Chongqing  P. R. China College of Resources & Environmental Science  Chongqing University  Chongqing  P. R. Chin
作者单位:LIU Zuohua 1,LIU Renlong 1,DU Jun 1,TAO Changyuan 1,LI Xiaohong 2 1College of Chemistry & Chemical Engineering,Chongqing University,Chongqing 400030,P. R. China 2College of Resources & Environmental Science,Chongqing University,Chongqing 400030,P. R. China
摘    要:1.IntroductionPhenolisanimportantchemicalindustrymaterial,butitalsoaboundswithserioushazardtoenvironmentandthreatstohumanhealth.Rigidruleshavebeenmadeoutonthephenoldischargeconcentration.Researchesonthetreatmentofphenolwastewaterwerecarriedoutinvariouscountries1-5].Membraneseparationmethodsincludingreverseosmosis,ultrafiltrationandpervaporationhaveattractedmuchattentionforphenolwastewatertreatment,withcelluloseacetate(CA)membraneemployedmostly6].Membranedistillationisanewmembraneseparation…

关 键 词:真空膜蒸馏法  苯酚废水  膜材料  废水处理  聚乙烯亚乙酰基氟化物  膜分离技术

Removal of aqueous phenol compound by vacuum membrane distillation
LIU Zuohu,LIU Renlong,DU Jun,TAO Changyuan,LI Xiaohong College of Chemistry & Chemical Engineering,Chongqing University,Chongqing,P. R. China College of Resources & Environmental Science,Chongqing University,Chongqing,P. R. Chin.Removal of aqueous phenol compound by vacuum membrane distillation[J].Journal of Chongqing University,2004,3(1):61-64.
Authors:Liu Zuohu  LIU Renlong  DU Jun  TAO Changyuan  LI Xiaohong
Abstract:The effects of feed temperature and pH value on the removal of aqueous phenol wastewater by vacuum membrane distillation process are studied by experiments employing micro porous membranes of poly vinylidene fluoride (PVDF) and ploy tetrafluoro ethylene (PTFE) with nominal average pore sizes 0.22 μm and 0.20 ?m, respectively. It is found that the optimal feed temperature for PVDF membrane is 50 ℃; and for PTFE membrane, 60 ℃. The pH value of the feed has little influence on the membrane fluxes and ion rejection ratios, while it influenced considerably on the selectivity. Increase of pH value of the feed is conducive to the increase of selectivity. In the same experimental conditions, PTFE membrane shows better separation performance than PVDF membrane does.
Keywords:vacuum membrane distillation (VMD)  phenol wastewater  membrane material
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《重庆大学学报(英文版)》浏览原始摘要信息
点击此处可从《重庆大学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号