首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
结合训练实践,运用ISOMED2000等速测试仪对我国男子散打主力队员膝、肘关节屈伸肌群肌力特征进行测试与分析。结论:不同等级散打运动员肘关节屈伸肌群等速向心、离心收缩、膝关节伸肌群等速离心收缩相对峰力矩值在60°/s、180°/s时具有显著性差异(P<0.05);膝关节屈伸肌群等速向心收缩、屈肌群离心收缩相对峰力矩值在各角速度下具有显著性差异(P<0.05);不同等级散打运动员肘、膝关节屈伸肌群等速向心收缩在300°/s、离心收缩在240°/s时达到力矩梯度最大值,且差异显著。说明基础力量、中快速力量及快速动作爆发力能较好地反映专项运动水平,相对峰力矩、力矩梯度数值越大,专项水平越高。  相似文献   

2.
目的:分析浙江师范大学投掷训练队优秀运动员腰背肌的生物力学特征,探讨投掷运动员的成绩与腰背屈伸肌群力量的关系,为投掷训练和易受伤部位的预防提供理论依据。方法:利用德国Isomed2000等速肌力测试系统进行核心力量等速肌力测试,测试严格按照Isomed2000等速测试系统使用手册的要求进行操作。结果:优秀投掷运动员腰背屈伸肌群等速向心收缩峰力矩随测试速度(30°/s~180°/s)的增加大体呈递减趋势,且随着角速度的增大,优秀投掷运动员的腰背屈伸肌群等速向心收缩峰力矩下降幅度(斜率K:伸-0.884小于屈-0.655)比普通人(K:伸-0.275小于屈-0.035)小,且优秀投掷运动员伸肌最大峰力矩的下降幅度要比屈肌小;在角速度为30°/s到120°/s时,最大功率随着给定角速度的增大而增大,在180°/s时又有所减小;腰背屈伸肌群峰力矩的角度在30°/s到180°/s时伸肌55.5°~58°大于屈肌的54.5°~56.25°,随着角速度的增大,大体呈上升趋势,在30°/s时峰力矩角度最小。  相似文献   

3.
Abstract

The aims of the present study were to assess the ability of explosive concentric contractions to induce high-frequency fatigue, and to determine what effects the number of repetitions and number of sets have upon peripheral fatigue. Nine male students performed two protocols (6 sets, 5 min and 1 week rest between sets and protocols, respectively) with a different number of concentric jumps in a set on the sledge (10 vs. 20 jumps in the first (S10) and the second protocol (S20), respectively). Isometric twitch torque, torque during low-frequency (20 Hz) and high-frequency (100 Hz) electrical stimulation of the vastus lateralis were measured (before protocols and 30 s after sets). Peak twitch torque increased, while contraction and half-relaxation times shortened during the S10 protocol (P<0.05). The increase in peak twitch torque was accompanied by non-significant reductions in contraction time and half-relaxation time in the S20 protocol. High- and low-frequency torques did not change significantly in either protocol. The high- to low-frequency torque ratio increased significantly (P<0.05) after the fourth set in the S10 protocol. Post-activation potentiation was the main reason for enhanced contractile response after both protocols. There were no alterations in high-frequency torque or reductions in the high- to low-frequency torque ratio, even with increased sets and repetitions. Explosive concentric contractions showed no potential to induce high-frequency fatigue, when separated with long periods of rest.  相似文献   

4.
This study assessed muscular torque and rate of torque development following concentric (CON) or eccentric (ECC) isokinetic training. Thirty-eight women were randomly assigned to either CON or ECC training groups. Training consisted of knee extension and flexion of the nondominant leg three times per week for 20 weeks (SD = 1). Eccentric training increased ECC knee extension and flexion peak torque more than CON training. The ECC group improved acceleration time and time to peak torque with ECC movements versus the CON group. Slow-velocity ECC isokinetic training yielded greater ECC and similar CON torque development gains versus CON training over the course of 20 weeks in young women.  相似文献   

5.
方法:利用CONTREX等速肌力测试与训练系统,以180°/s、120°/s、60°/s3种角速度对苏州市自行车训练队26名运动员右腿膝关节进行等速向心屈伸测试。目的:分析自行车运动员不同角速度下等速向心收缩与膝关节肌肌力的关系及肌力特征。结果:1、屈伸肌峰力矩随速度的增加呈减小趋势。2、到达峰力矩的时间随测试速度的增加而缩短。且男女运动员在180°/s与120°/s组间均无显著差异。3、膝关节相对平均功率伸肌均大于屈肌,120°/ts时,屈伸肌的相对平均功率最大。4、屈伸肌比在64.8%~70.6%内,有随速度增加而增加的趋势。结论:以60°/s的角速度训练肌肉最大力量效果更明显;爆发力在120°/s时训练效果最佳;屈/伸肌比值(H/Q)在正常范围内,但低于优秀运动员(优秀运动员可达80%以上)。  相似文献   

6.
This study was undertaken to examine the acute effect of interferential current on mechanical pain threshold and isometric peak torque after delayed onset muscle soreness induction in human hamstrings. Forty-one physically active healthy male volunteers aged 18-33 years were randomly assigned to one of two experimental groups: interferential current group (n = 21) or placebo group (n = 20). Both groups performed a bout of 100 isokinetic eccentric maximal voluntary contractions (10 sets of 10 repetitions) at an angular velocity of 1.05 rad · s(-1) (60° · s(-1)) to induce muscle soreness. On the next day, volunteers received either an interferential current or a placebo application. Treatment was applied for 30 minutes (4 kHz frequency; 125 μs pulse duration; 80-150 Hz bursts). Mechanical pain threshold and isometric peak torque were measured at four different time intervals: prior to induction of muscle soreness, immediately following muscle soreness induction, on the next day after muscle soreness induction, and immediately after the interferential current and placebo application. Both groups showed a reduction in isometric torque (P < 0.001) and pain threshold (P < 0.001) after the eccentric exercise. After treatment, only the interferential current group showed a significant increase in pain threshold (P = 0.002) with no changes in isometric torque. The results indicate that interferential current was effective in increasing hamstrings mechanical pain threshold after eccentric exercise, with no effect on isometric peak torque after treatment.  相似文献   

7.
Knee flexor and extensor muscular assessment via isokinetic dynamometry is common practice and established in the research literature. However, reporting assessment methodology regarding reciprocal and nonreciprocal movements is often vague or absent. Such methodological issues are crucial for accurate assessments. Therefore, knee extensor and flexor peak moment using either reciprocal movement or nonreciprocal modalities was assessed. Fifteen participants performed three blocks of five concentric muscle actions at three angular velocities [1: nonreciprocal (maximal active flexion followed by passive extension); B2: reciprocal (maximal active extension followed by maximal active flexion); B3 nonreciprocal (maximal active extension followed by passive flexion)]. ANOVA revealed statistically significant within-subject modality effects for peak knee extensor moment and flexor velocity and modality differences (p < .05). Reciprocal and nonreciprocal assessments give significantly different results, with nonreciprocal giving higher peak moments. Reporting which modality is used is crucial to allow for greater clarity for the reader and practitioner.  相似文献   

8.
The objective of this study was to investigate the effects of a simulated futsal match protocol on isokinetic knee torque production. Twenty-one young futsal players participated in this study and performed a futsal-specific protocol comprising two blocks of 20-minute activities to simulate the match demands. At pre-protocol, half-time, and post-protocol, the concentric and eccentric isokinetic peak torque of the knee flexor and extensor muscles, the angle of peak torque, and the conventional and functional torque ratios were assessed. ANOVA was used to compare the variables (significance level p < 0.05). A decrease of knee flexor and extensor eccentric torque and knee flexor concentric torque was found, in which the pre-protocol levels were higher than those at half-time, with both being larger than those at post-protocol. The knee extensor concentric torque reduced at half-time. The angle of eccentric torque of knee flexors increased, and the conventional and functional torque ratios decreased at post-protocol. In conclusion, the protocol produced a time-dependent reduction of knee flexor and extensor torque in both concentric and eccentric actions. These findings suggested a possible impairment of performance and the emergence of risk factors for hamstring strains during a futsal match.  相似文献   

9.
This study investigated the effect of low- and high-velocity resistance training on isokinetic peak torque and anaerobic power output. Eighteen male varsity oarsmen were blocked on peak knee extension torque at 3.14 rad s-1 and assigned to a high-velocity resistance training group (HVR), a low-velocity resistance training group (LVR) or a control group. Subjects trained four times a week for 5 weeks. Each training session included three circuits of 12 stations using variable-resistance hydraulic equipment. The HVR training significantly improved peak torque (P less than 0.05) in knee extension and flexion at 2.61, 3.14, 3.66 and 4.19 rad s-1. The LVR training produced significant improvements (P less than 0.05) in peak torque for knee extension and flexion at 0.52, 1.05, 1.57 and 2.61 rad s-1. High positive correlations were found between peak torque and anaerobic power outputs for all groups. However, no significant changes occurred in 15 s power output, average 90 s power output or peak blood lactate in either training group. These results indicate that velocity-specific strength training does not necessarily improve anaerobic power output in a different exercise mode despite the high positive correlation between isokinetic strength and anaerobic power output.  相似文献   

10.
目的:通过对湖南师范大学9名北狮运动员双侧膝关节屈伸肌群进行等速测试,为揭示该项运动膝关节肌群收缩的生物力学特性提供实验依据。方法:采用BIODEX SYSTEM 3等速测试系统对湖南师范大学北狮运动员膝关节屈伸肌群进行等速测试,测试指标为峰力矩、相对峰力矩、屈伸肌峰力矩比、平均功率及做功疲劳度。结果:1)北狮运动员双侧膝关节屈伸肌峰力矩和相对峰力矩随测试速度的增加呈递减趋势;2)狮头狮尾屈伸肌群峰力矩比值和做功疲劳度无显著性差异;3)狮头狮尾左右膝关节同一肌群峰力矩无显著性差异。结论:舞狮运动员膝关节肌群峰力矩变化随测试速度的增加而减少,平均功率呈现随运动速度的增加而增加,到达一定速度后随速度的增加而减少的特征。  相似文献   

11.
PurposeThe purpose of this study was to examine the reliability and the learning effect of an isokinetic trunk flexion–extension protocol designed to simultaneously assess trunk muscle strength and endurance. In addition, the effect of the participants' sex on the reliability data was examined.MethodsFifty-seven healthy and physically active young men (n = 28) and women (n = 29) performed the isokinetic protocol 5 times, separated by a week between each of the first 4 sessions and by a month between the last 2 sessions. The protocol consisted of performing 4 trials of 15 maximum flexion–extension concentric exertions at 120°/s (range of trunk motion = 50°). The absolute and relative peak torque and total work were calculated to assess trunk flexion and extension strength. In addition, endurance ratio, modified endurance ratio, fatigue final ratio, recovery ratio, and modified recovery ratio variables were used for the assessment of trunk muscle endurance in both directions.ResultsRegarding the absolute reliability, no relevant changes were found between paired-comparison sessions for most strength and endurance variables, except for total work and relative total work variables in the flexion movement in both sexes. In addition, the typical error of the isokinetic variables was lower than 10% in both males and females, and minimum detectable changes ranged from 7% to 20%, with a tendency to be higher in females and in endurance variables. The strength variables showed high-to-excellent intraclass correlation coefficients (ICCs; >0.74); however, for the endurance variables only the endurance ratio and the modified endurance ratio obtained moderate-to-high ICC values (0.57 < ICC < 0.82). In addition, the analysis of the variance reported no significant differences between consecutive pairs of sessions for most variables in both sexes.ConclusionOverall, these findings provide clinicians, trainers, and researchers with a 10-min single-session protocol to perform a reliable muscle strength and endurance evaluation of trunk flexor and extensor muscles, all within the same protocol.  相似文献   

12.
The aim of this study was to determine the effects of 7 weeks of high- and low-velocity resistance training on strength and sprint running performance in nine male elite junior sprint runners (age 19.0 - 1.4 years, best 100 m times 10.89 - 0.21 s; mean - s ). The athletes continued their sprint training throughout the study, but their resistance training programme was replaced by one in which the movement velocities of hip extension and flexion, knee extension and flexion and squat exercises varied according to the loads lifted (i.e. 30-50% and 70-90% of 1-RM in the high- and low-velocity training groups, respectively). There were no between-group differences in hip flexion or extension torque produced at 1.05, 4.74 or 8.42 rad·s -1 , 20 m acceleration or 20 m 'flying' running times, or 1-RM squat lift strength either before or after training. This was despite significant improvements in 20 m acceleration time ( P ? 0.01), squat strength ( P ? 0.05), isokinetic hip flexion torque at 4.74 rad·s -1 and hip extension torque at 1.05 and 4.74 rad·s -1 for the athletes as a whole over the training period. Although velocity-specific strength adaptations have been shown to occur rapidly in untrained and non-concurrently training individuals, the present results suggest a lack of velocity-specific performance changes in elite concurrently training sprint runners performing a combination of traditional and semi-specific resistance training exercises.  相似文献   

13.
跳远运动员专项成绩与专项身体素质相关关系的研究   总被引:1,自引:0,他引:1  
对我国 10名男子跳远运动员的专项成绩、专项身体素质以及下肢髋、膝和踝 3大关节等速屈伸肌力矩等指标进行测试。通过相关分析探讨了跳远运动员专项身体素质、下肢力量水平与专项成绩之间的关系 ,发现髋关节屈伸肌肌力、膝关节屈伸肌肌力和伸肌的离心肌力以及踝关节的跖屈肌力与跳远成绩相关  相似文献   

14.
跳高运动员专项身体素质与专项成绩相关关系的研究   总被引:3,自引:1,他引:2  
对 8名男子跳高运动员进行了专项成绩和身体素质测验 ,同时测试了运动员下肢髋、膝、踝 3个关节的等速屈伸肌力。通过相关分析探讨了跳高运动员专项身体素质、下肢力量水平与专项成绩之间的关系。结果表明 ,髋关节屈伸肌力矩、膝关节伸肌力矩、踝关节跖屈肌力矩与跳高专项成绩相关。  相似文献   

15.
The aim of this study was to determine the effects of 7 weeks of high- and low-velocity resistance training on strength and sprint running performance in nine male elite junior sprint runners (age 19.0+/-1.4 years, best 100 m times 10.89+/-0.21 s; mean +/- s). The athletes continued their sprint training throughout the study, but their resistance training programme was replaced by one in which the movement velocities of hip extension and flexion, knee extension and flexion and squat exercises varied according to the loads lifted (i.e. 30-50% and 70-90% of 1-RM in the high- and low-velocity training groups, respectively). There were no between-group differences in hip flexion or extension torque produced at 1.05, 4.74 or 8.42 rad x s(-1), 20 m acceleration or 20 m 'flying' running times, or 1-RM squat lift strength either before or after training. This was despite significant improvements in 20 m acceleration time (P < 0.01), squat strength (P < 0.05), isokinetic hip flexion torque at 4.74 rad x s(-1) and hip extension torque at 1.05 and 4.74 rad x s(-1) for the athletes as a whole over the training period. Although velocity-specific strength adaptations have been shown to occur rapidly in untrained and nonconcurrently training individuals, the present results suggest a lack of velocity-specific performance changes in elite concurrently training sprint runners performing a combination of traditional and semi-specific resistance training exercises.  相似文献   

16.
The aim of the present study was to examine the relationships between muscle cross-sectional area (CSA) and muscular strength in terms of knee extension and flexion, hip extension and flexion, and hip abduction and adduction among well-trained soccer players. Fourteen university soccer players participated in the study, who had previously been divided into two groups based on ability (Group A: above-average ability; Group B: average ability). Maximal isokinetic and concentric muscular strength was measured in knee extension/flexion, hip extension/flexion and hip abduction/adduction using an isokinetic dynamometer at 1.57 and 4.19 rad x s(-1) (3.14 rad x s(-1)) in both the dominant and non-dominant leg. The CSAs of the thigh, gluteus muscles and iliopsoas muscles were calculated based on magnetic resonance imaging. There was no significant difference between the two groups in muscle CSA and isokinetic strength. Although there were some statistically significant differences between the dominant and non-dominant leg in terms of CSA and strength (P < 0.05-0.01), these were small and negligible. Apart from a non-significant relationship between the CSAs of the adductor muscles and hip adductor strength (r < 0.26, N.S.), the CSA of the other muscle groups correlated with maximal isokinetic strength (r = 0.38-0.64, P < 0.05). These results suggest that no difference in muscle characteristics (in terms of muscle CSA and strength) was apparent among well-trained soccer players, even between the dominant and non-dominant leg. There is also a case that the anatomical function of a single (or group of) muscle(s) may not be reflected by the strength-CSA relationship depending on the movements (such as hip adduction-adductor muscle CSA). Thus, further studies are required to develop methods to assess neuromuscular function in relation to muscle morphology among soccer players.  相似文献   

17.
In this study, we evaluated the peak torque, functional torque ratios, and torque curve profile of the shoulder rotators in overhead athletes with impingement symptoms so as to examine possible alterations in response to sports training and shoulder pain. Twenty-one overhead athletes with impingement symptoms were compared with 25 overhead athletes and 21 non-athletes, none of whom were symptomatic for impingement. The participants performed five maximal isokinetic concentric and eccentric contractions of medial and lateral shoulder rotations at 1.57 rad · s(-1) and 3.14 rad · s(-1). Isokinetic peak torque was used to calculate the eccentric lateral rotation-to-concentric medial rotation and the eccentric medial rotation-to-concentric lateral rotation ratios. An analysis of the torque curve profiles was also carried out. The eccentric lateral rotation-to-concentric medial rotation torque ratio of asymptomatic athletes was lower than that of non-athletes at both test velocities. The concentric medial rotation isokinetic peak torque of the asymptomatic athletes, at 3.14 rad · s(-1), was greater than that of the non-athletes, and the peak appeared to occur earlier in the movement for athletes than non-athletes. These findings suggest that there may be adaptations to shoulder function in response to throwing practice. The eccentric medial rotation-to-concentric lateral rotation torque ratio was altered neither by the practice of university-level overhead sports nor impingement symptoms.  相似文献   

18.
Altogether, 100 uninjured professional rugby league players were evaluated over a 2-year period. Their height, body mass, sum of skinfolds, girths and bone diameters were recorded. A Cybex 340 isokinetic dynamometer was used to determine peak torque, work, power, endurance ratios and peak torque ratios of the hip abductors and adductors (5 repetitions at 0.52 and 2.08 rad. s(- 1); 20 repetitions at 3.66 rad. s(- 1)) and knee flexors and extensors (4 repetitions at 1.04 and 3.14 rad. s(- 1); 30 repetitions at 5.22 rad. s(- 1)). Hip abduction and adduction were also assessed with the hip in external rotation. Discriminant function analysis was conducted on all predictor variables to develop a multivariate predictive model capable of classifying players with a high degree of accuracy into groups with and without a groin injury. The model consisted of eight variables and correctly classified 91.7% of the non-injured players and 90.5% of the injured players. The correct classification for the model as a whole was 91.4%. The aetiological factors identified as being related to injury of the groin musculotendinous unit included abduction and adduction-with-rotation peak torque, angle of adduction and abduction-with-rotation peak torque, strength ratio of hip muscle groups, bilateral difference in extension peak torque, femur diameter and body mass.  相似文献   

19.
In this crossover study, we wished to determine if normalized inter-limb differences in strength differed from inter-limb differences in voluntary activation at 30°, 70°, and 90° of knee flexion. We also assessed the relationship between inter-limb differences in torque with the inter-limb differences in activation. Twenty-five healthy volunteers were used for final data analyses; the order of leg tested, joint angle, and measurement technique (isokinetic strength, voluntary activation) were randomly assigned. Quadriceps strength was measured isokinetically at 1.05 rad · s(-1), while quadriceps voluntary activation was assessed via the central activation ratio. Absolute values of inter-limb differences for both measures were calculated by subtracting the non-dominant leg values from those of the dominant leg. Inter-limb isokinetic strength differences were greater than inter-limb central activation ratio differences at all joint angles (P = 0.003). Interestingly, inter-limb deficits between measures were not strongly correlated, suggesting that these measurements may be evaluating completely different phenomena within the neuromuscular system. These measurement techniques may provide unique information regarding neuromuscular function, suggesting that researchers and clinicians must utilize information from both techniques to determine the true clinical nature of inter-limb deficits.  相似文献   

20.
The aim of this study was to examine joint power generation during a concentric knee extension isokinetic test and a squat vertical jump. The isokinetic test joint power was calculated using four different methods. Five participants performed concentric knee extensions at 0.52, 1.57, 3.14 and 5.23 rad x s(-1) on a Lido isokinetic dynamometer. The squat vertical jump was performed on a Kistler force plate. Kinematic data from both tests were collected and analysed using an ELITE optoelectronic system. An inverse dynamics model was applied to measure knee joint moment in the vertical jump. Knee angular position data from the kinematic analysis in the isokinetic test were used to derive the actual knee angular velocity and acceleration, which, in turn, was used to correct the dynamometer moment for inertial effects. Power was measured as the product of angular velocity and moment at the knee joint in both tests. Significant differences (P < 0.05) were found between mean (+/- s) peak knee joint power in the two tests (squat vertical jump: 2255 +/- 434 W; isokinetic knee extension: 771 +/- 81 W). Correlation analysis revealed that there is no relationship between the peak knee joint power during the vertical jump and the slow velocity isokinetic tests. Higher isokinetic velocity tests show better relationships with the vertical jump but only if the correct method for joint power calculation is used in the isokinetic test. These findings suggest that there are important differences in muscle activation and knee joint power development that must be taken into consideration when isokinetic tests are used to predict jumping performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号