首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

The aims of this study were to determine if the primary time constant (τ) for oxygen uptake ([Vdot]O2) at the onset of moderate-intensity treadmill exercise is related to endurance running performance, and to establish if τ could be considered a determinant of endurance running performance. Thirty-six endurance trained male runners performed a series of laboratory tests, on separate days, to determine maximal oxygen uptake ([Vdot]O2max), the ventilatory threshold (VT) and running economy. In addition, runners completed six transitions from walking (4 km · h?1) to moderate-intensity running (80% VT) for the determination of the [Vdot]O2 primary time constant and mean response time. During all tests, pulmonary gas-exchange was measured breath-by-breath. Endurance running performance was determined using a treadmill 5-km time-trial, after which runners were considered as combined performers (n=36) and, using a ranking system, high performers (n=10) and low performers (n=10). Relationships between τ and endurance running performance were quantified using correlation coefficients (r). Stepwise multiple regression was used to determine the primary predictor variables of endurance running performance in combined performers. Moderate correlations were observed between τ, mean response time and endurance running performance, but only for the combined performers (r=?0.55, P=0.001 and r=?0.50, P=0.002, respectively). The regression model for predicting 5-km performance did not include τ or mean response time. The velocity at [Vdot]O2max was strongly correlated to endurance running performance in all groups (r=0.72 – 0.84, P < 0.01) and contributed substantially to the prediction of performance. In conclusion, the results suggest that despite their role in determining the oxygen deficit and having a moderate relationship with endurance running performance, neither τ nor mean response time is a primary determinant of endurance running performance.  相似文献   

2.
Abstract

The aim of the present study was to determine the repeatability of a running endurance test using an automated treadmill system that requires no manual input to control running speed. On three separate occasions, 7 days apart, 10 experienced male endurance-trained runners (mean age 32 years, s = 10; [Vdot]O2peak 61 ml · kg?1 · min?1, s = 7) completed a treadmill time trial, in which they were instructed to run as far as possible in 60 min. The treadmill was instrumented with an ultrasonic feedback-controlled radar modulator that spontaneously regulated treadmill belt speed corresponding to the changing running speed of each runner. Estimated running intensity was 70%[Vdot]O2peak (s = 11) and the distance covered 13.5 km (s = 2), with no difference in mean performances between trials. The coefficient of variation, estimated using analysis of variance, with participant and trial as main effects, was 1.4%. In summary, the use of an automated treadmill system improved the repeatability of a 60-min treadmill time trial compared with time trials in which speed is controlled manually. The present protocol is a reliable method of assessing endurance performance in endurance-trained runners.  相似文献   

3.
Abstract

The determination of the ventilatory threshold has been a persistent problem in research and clinical practice. Several computerized methods have been developed to overcome the subjectivity of visual methods but it remains unclear whether different computerized methods yield similar results. The purpose of this study was to compare nine regression-based computerized methods for the determination of the ventilatory threshold. Two samples of young and healthy volunteers (n = 30 each) participated in incremental treadmill protocols to volitional fatigue. The ventilatory data were averaged in 20-s segments and analysed with a computer program. Significant variance among methods was found in both samples (Sample 1: F = 11.50; Sample 2: F = 11.70, P < 0.001 for both). The estimates of the ventilatory threshold ranged from 2.47 litres · min?1 (71%[Vdot]O2max) to 3.13 litres · min?1 (90%[Vdot]O2max) in Sample 1 and from 2.37 litres · min?1 (67%[Vdot]O2max) to 3.03 litres · min?1 (83%[Vdot]O2max) in Sample 2. The substantial differences between methods challenge the practice of relying on any single computerized method. A standardized protocol, likely based on a combination of methods, might be necessary to increase the methodological consistency in both research and clinical practice.  相似文献   

4.
Abstract

The purpose of this study was to assess the relationships among ventilatory threshold T(vent), running economy and distance running performance in a group (N=9) of trained experienced male runners with comparable maximum oxygen uptake ([Vdot]O2 max). Maximal oxygen uptake and submaximal steady state oxygen uptake were measured using open circuit spirometry during treadmill exercise. Ventilatory threshold was determined during graded treadmill exercise using non-invasive techniques, while distance running performance was assessed by the best finish time in two 10-kilometer (km) road races. The subjects averaged 33.8 minutes on the 10km runs, 68.6 ml · kg -1 · min -1 for [Vdot]O2 max, and 48.1 ml · kg -1 · min -1 for steady state [Vdot]O2 running at 243 meters · min -1. The T(vent) (first deviation from linearity of [Vdot]E, [Vdot]CO 2 ) occurred at an oxygen consumption of 41.9 ml · kg -1 · min -1. The relationship between running economy and performance was r = .51 (p>0.15) and the relationship between T(vent) and performance was r = .94 (p < 0.001). Applying stepwise multiple linear regression, the multiple R did not increase significantly with the addition of variables to the T(vent); however, the combination of [Vdot]O2 max, running economy and T(vent) was determined to account for the greatest amount of total variance (89%). These data suggest that among trained and experienced runners with similar [Vdot]O2 max, T(vent) can account for a large portion of the variance in performance during a 10km race.  相似文献   

5.
Abstract

The purpose of this study was to assess the effects of heavy resistance, explosive resistance, and muscle endurance training on neuromuscular, endurance, and high-intensity running performance in recreational endurance runners. Twenty-seven male runners were divided into one of three groups: heavy resistance, explosive resistance or muscle endurance training. After 6 weeks of preparatory training, the groups underwent an 8-week resistance training programme as a supplement to endurance training. Before and after the 8-week training period, maximal strength (one-repetition maximum), electromyographic activity of the leg extensors, countermovement jump height, maximal speed in the maximal anaerobic running test, maximal endurance performance, maximal oxygen uptake ([Vdot]O2max), and running economy were assessed. Maximal strength improved in the heavy (P = 0.034, effect size ES = 0.38) and explosive resistance training groups (P = 0.003, ES = 0.67) with increases in leg muscle activation (heavy: P = 0.032, ES = 0.38; explosive: P = 0.002, ES = 0.77). Only the heavy resistance training group improved maximal running speed in the maximal anaerobic running test (P = 0.012, ES = 0.52) and jump height (P = 0.006, ES = 0.59). Maximal endurance running performance was improved in all groups (heavy: P = 0.005, ES = 0.56; explosive: P = 0.034, ES = 0.39; muscle endurance: P = 0.001, ES = 0.94), with small though not statistically significant improvements in [Vdot]O2max (heavy: ES = 0.08; explosive: ES = 0.29; muscle endurance: ES = 0.65) and running economy (ES in all groups < 0.08). All three modes of strength training used concurrently with endurance training were effective in improving treadmill running endurance performance. However, both heavy and explosive strength training were beneficial in improving neuromuscular characteristics, and heavy resistance training in particular contributed to improvements in high-intensity running characteristics. Thus, endurance runners should include heavy resistance training in their training programmes to enhance endurance performance, such as improving sprinting ability at the end of a race.  相似文献   

6.
Abstract

In this study, we assessed the ventilatory response in 84 children (46 males: age 8.1 ± 1.0 years, body mass 34.2 ± 7.9 kg, height 1.32 ± 0.16 m; 38 females: age 8.0 ± 0.8 years, body mass 31.7 ± 8.7 kg, height 1.31 ± 0.08 m) during a cycle ergometer test to determine if there was an influence of gender on ventilatory efficiency. The test commenced at 25 W and increased by 10 W every minute. Expired air was collected through a face mask and analysed breath by breath. The ventilatory anaerobic threshold was determined according to gas exchange methods and we focused our attention on the analysis of carbon dioxide production ([Vdot]CO2), ventilation ([Vdot] E), the ratio [Vdot] E/[Vdot]CO2 and its slope. Differences between the sexes at maximal power output were strongly significant for [Vdot] E and [Vdot]CO2 (P = 0.0001 and P = 0.0004 respectively) and moderately significant for the [Vdot] E/[Vdot]CO2 ratio (P = 0.05). The slope of [Vdot] E versus [Vdot]CO2 was 30.8 ± 4.2 for males and 29.4 ± 3.2 for females, with no difference between the sexes (P = 0.1). In conclusion, although the peak values of [Vdot] E and [Vdot]CO2 were significantly different between the sexes, there were no such differences in ventilatory efficiency during a maximal incremental test expressed as the slope of [Vdot] E/[Vdot]CO2, at least in young children.  相似文献   

7.
8.
Abstract

The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6×3 min at 90% [Vdot]O2max interspersed with 6×3 min active recovery at 50% [Vdot]O2max with a 7-min warm-up and cool down at 70% [Vdot]O2max) or 50 min moderate-intensity continuous running at 70% [Vdot]O2max. Ratings of perceived enjoyment after exercise were higher (P < 0.05) following interval running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P < 0.05) ratings of perceived exertion (14 ± 1 vs. 13 ± 1). There was no difference (P < 0.05) in average heart rate (88 ± 3 vs. 87 ± 3% maximum heart rate), average [Vdot]O2 (71 ± 6 vs. 73 ± 4%[Vdot]O2max), total [Vdot]O2 (162 ± 16 vs. 166 ± 27 L) or energy expenditure (811 ± 83 vs. 832 ± 136 kcal) between protocols. The greater enjoyment associated with high-intensity interval running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.  相似文献   

9.
Abstract

The aim of this study was to assess the effects of nicotinamide adenine dinucleotide hydride (NADH) on maximal oxygen uptake ([Vdot]O2max), maximal anaerobic running time, and mental performance. Eight men were exposed to a supplement treatment (30 mg NADH as ENACHI tablets per day) and to a placebo treatment, each of 4 weeks' duration, in a balanced, double-blind, and cross-over design. The two treatments were separated by a 14-week wash-out period. The results indicated that [Vdot]O2max, maximal anaerobic running time, and the ability to concentrate were similar in the NADH and placebo conditions. There were also no differences in blood lactate, creatine kinase, reaction time or feelings of fatigue between the treatments. A counter-movement jump performed at rest and 2 min after the aerobic test differed significantly (P ≤ 0.05) between the treatment conditions and was higher in the NADH group. In conclusion, the NADH supplementation for 4 weeks had no effects on [Vdot]O2max, maximal anaerobic running time or mental performance.  相似文献   

10.
Abstract

The aims of the study were to modify the training impulse (TRIMP) method of quantifying training load for use with intermittent team sports, and to examine the relationship between this modified TRIMP (TRIMPMOD) and changes in the physiological profile of team sport players during a competitive season. Eight male field hockey players, participating in the English Premier Division, took part in the study (mean±s: age 26±4 years, body mass 80.8±5.2 kg, stature 1.82±0.04 m). Participants performed three treadmill exercise tests at the start of the competitive season and mid-season: a submaximal test to establish the treadmill speed at a blood lactate concentration of 4 mmol · l?1; a maximal incremental test to determine maximal oxygen uptake ([Vdot]O2max) and peak running speed; and an all-out constant-load test to determine time to exhaustion. Heart rate was recorded during all training sessions and match-play, from which TRIMPMOD was calculated. Mean weekly TRIMPMOD was correlated with the change in [Vdot]O2max and treadmill speed at a blood lactate concentration of 4 mmol · l?1 from the start of to mid-season (P<0.05). The results suggest that TRIMPMOD is a means of quantifying training load in team sports and can be used to prescribe training for the maintenance or improvement of aerobic fitness during the competitive season.  相似文献   

11.
Abstract

Percent body fat, ratings of perceived exertion and maximal oxygen consumption during a continuous running treadmill test were obtained on 127 high school female cross country runners. These young runners (x 15.6 yrs) were running approximately 25 miles per week at the time of testing. They had an average [Vdot]O2 max of 50.8 ml · min-1 and an HR max of 198.0 bpm. The mean percent body fat, as determined from hydrostatic weighing, was 15.4%. The onset of metabolic acidosis was estimated to occur at 78% of [Vdot]O2 max. A stepwise multiple regression with the 3000 meter run as the dependent variable indicated that max treadmill run time, weight relative [Vdot]O2 max and [Vdot] max entered the equation in that order, yielding an R of 0.67. Both HR and RPE increased with work intensity, but not at equal rates. These high school female runners had higher [Vdot]O2 max's than previously reported for this age group; however, they were considerably below these values reported for national caliber distance runners.  相似文献   

12.
Abstract

The aim of this study was to examine the acute effects of prolonged static stretching (SS) on running economy. Ten male runners ([Vdot]O2peak 60.1 ± 7.3 ml · kg?1 · min?1) performed 10 min of treadmill running at 70%[Vdot]O2peak before and after SS and no stretching interventions. For the stretching intervention, each leg was stretched unilaterally for 40 s with each of eight different exercises and this was repeated three times. Respiratory gas exchange was measured throughout the running exercise with an automated gas analysis system. On a separate day, participants were tested for sit and reach range of motion, isometric strength and countermovement jump height before and after SS. The oxygen uptake, minute ventilation, energy expenditure, respiratory exchange ratio and heart rate responses to running were unaffected by the stretching intervention. This was despite a significant effect of SS on neuromuscular function (sit and reach range of motion, +2.7 ± 0.6 cm; isometric strength, ?5.6% ± 3.4%; countermovement jump height ?5.5% ± 3.4%; all P < 0.05). The results suggest that prolonged SS does not influence running economy despite changes in neuromuscular function.  相似文献   

13.
Abstract

Maximal oxygen uptake ([Vdot]O2max) is considered the optimal method to assess aerobic fitness. The measurement of [Vdot]O2max, however, requires special equipment and training. Maximal exercise testing with determination of maximal power output offers a more simple approach. This study explores the relationship between [Vdot]O2max and maximal power output in 247 children (139 boys and 108 girls) aged 7.9–11.1 years. Maximal oxygen uptake was measured by indirect calorimetry during a maximal ergometer exercise test with an initial workload of 30 W and 15 W · min?1 increments. Maximal power output was also measured. A sample (n = 124) was used to calculate reference equations, which were then validated using another sample (n = 123). The linear reference equation for both sexes combined was: [Vdot]O2max (ml · min?1) = 96 + 10.6 · maximal power + 3.5 · body mass. Using this reference equation, estimated [Vdot]O2max per unit of body mass (ml · min?1 · kg?1) calculated from maximal power correlated closely with the direct measurement of [Vdot]O2max (r = 0.91, P <0.001). Bland-Altman analysis gave a mean limits of agreement of 0.2±2.9 (ml · min?1 · kg?1) (1 s). Our results suggest that maximal power output serves as a good surrogate measurement for [Vdot]O2max in population studies of children aged 8–11 years.  相似文献   

14.
Abstract

The aim of the present study was to determine the effect of a carbohydrate mouthwash on running time-trial performance. On two separate occasions, seven recreationally active males ([Vdot]O2max 57.8 ml · kg?1 · min?1, s = 3.7) completed a preloaded (15 min at 65%[Vdot]O2max) time-trial of 45 min in duration on a motorized treadmill. At 6-min intervals during the preload and time-trial, participants were given either a 6% maltodextrin, 3% lemon juice solution (carbohydrate trial) or a 3% lemon juice placebo mouthwash (placebo trial) in a double-blind, randomized crossover design. Heart rate, oxygen consumption ([Vdot]O2), respiratory exchange ratio (RER), and ratings of perceived exertion (RPE) were measured during the preload, and blood glucose and lactate were measured before and after the preload and time-trial. There were no significant differences in distance covered between trials (carbohydrate: 9333 m, s = 988; placebo: 9309 m, s = 993). Furthermore, there were no significant between-trial differences in heart rate and running speed during the time-trial, or [Vdot]O2, RER or RPE during the preload. Blood lactate and glucose increased as a result of the exercise protocol, with no between-trial differences. In conclusion, there was no positive effect of a carbohydrate mouthwash on running performance of ~1 h duration.  相似文献   

15.
Abstract

In this study, we investigated the effect of biological maturation on maximal oxygen uptake ([Vdot]O2max) and ventilatory thresholds (VT1 and VT2) in 110 young soccer players separated into pubescent and post-pubescent groups.. Maximal oxygen uptake and [Vdot]O2 corresponding to VT1 and VT2 were expressed as absolute values, ratio standards, theoretical exponents, and experimentally observed exponents. Absolute [Vdot]O2 (ml · min?1) was different between groups for VT1, VT2, and [Vdot]O2max. Ratio standards (ml · kg?1 · min?1) were not significantly different between groups for VT1, VT2, and [Vdot]O2max. Theoretical exponents (ml · kg?0.67 · min?1 and ml · kg?0.75 · min?1) were not properly adjusted for the body mass effects on VT1, VT2, and [Vdot]O2max. When the data were correctly adjusted using experimentally observed exponents, VT1 (ml · kg?0.94 · min?1) and VT2 (ml · kg?0.95 · min?1) were not different between groups. The experimentally observed exponent for [Vdot]O2max (ml · kg?0.90 · min?1) was different between groups (P = 0.048); however, this difference could not be attributed to biological maturation. In conclusion, biological maturation had no effect on VT1, VT2 or [Vdot]O2max when the effect of body mass was adjusted by experimentally observed exponents. Thus, when evaluating the physiological performance of young soccer players, allometric scaling needs to be taken into account instead of using theoretical approaches.  相似文献   

16.
Abstract

Maximum oxygen uptake ([Vdot]O2PEAK) is generally considered to be the best single marker for aerobic fitness. While a positive relationship between daily physical activity and aerobic fitness has been established in adults, the relationship appears less clear in children and adolescents. The purpose of this paper is to summarise recently published data on the relationship between daily physical activity, as measured by accelerometers, and [Vdot]O2PEAK in children and adolescents. A PubMed search was performed on 29 October 2010 to identify relevant articles. Studies were considered relevant if they included measurement of daily physical activity by accelerometry and related to a [Vdot]O2PEAK either measured directly at a maximal exercise test or estimated from maximal power output. A total of nine studies were identified, with a total number of 6116 children and adolescents investigated. Most studies reported a low-to-moderate relationship (r = 0.10–0.45) between objectively measured daily physical activity and [Vdot]O2PEAK. No conclusive evidence exists that physical activity of higher intensities are more closely related to [Vdot]O2PEAK, than lower intensities.  相似文献   

17.
Abstract

The aim of this study was to assess and compare the validity of the portable VmaxST telemetry metabolic measurement device with that of a standard measurement system (Vmax29). Thirty asymptomatic, moderately active males provided written, informed consent and completed two maximal graded treadmill exercise tests (Bruce) using the VmaxST and the Vmax29 metabolic measurement systems. Tests were performed in random order on separate days to obtain peak values for time to exhaustion, heart rate, systolic and diastolic blood pressure, oxygen consumption ([Vdot]O2), carbon dioxide production ([Vdot]CO2), ventilation ([Vdot] E), and respiratory exchange ratio (RER). Multivariate analysis of variance revealed no significant main effect (P = 0.88) between the two systems across any variable, suggesting similar measurement capabilities between the two systems. Linear regression analyses revealed moderate to high coefficients of determination for [Vdot]O2 (r 2 = 0.99), [Vdot]CO2 (r 2 = 0.99), [Vdot] E (r 2 = 0.99), and RER (r 2 = 0.89). Furthermore, Bland-Altman analyses demonstrated that the VmaxST yielded similar values to the Vmax29, suggesting good agreement between the two systems. Agreement was confirmed when the differences between the methods resulted in a small range as identified by the 95% limits of agreement. Findings from the current study confirm that the VmaxST is a valid device for measuring metabolic and physiological variables during exercise within a controlled laboratory setting.  相似文献   

18.
Abstract

We followed up on recent findings demonstrating that enhancing performers' expectancies can improve their performance. Specifically, we examined whether providing experienced runners with positive feedback regarding their movement efficiency would increase running efficiency. Two groups of experienced runners ran on a treadmill at 75% of their maximum oxygen consumption ([Vdot]O2max) for 10 min. One group (enhanced expectancy) was provided with (fabricated) feedback about the efficiency of their running style every 2 min. A control group was not given feedback. Oxygen consumption decreased in the enhanced expectancy group across measurement times (every 2 min for 10 min), but remained the same in the control group. In addition, performance perceptions changed only in the enhanced expectancy group, indicating a perception of greater ease of running and reduced fatigue when assessed after compared with before running. Finally, positive affect increased from a pre- to a post-test in the enhanced expectancy group, in contrast to the control group. Our findings show that enhanced expectancies can have a positive effect on movement efficiency and running experience. They add to the accumulating evidence for the social-cognitive-affective-motor nature of motor performance.  相似文献   

19.
Abstract

Eight male and eight female runners were matched on performance in a 24.2 km (15 mile) road race (X time ± SD = 115.1 ± 2.2 min for females, 115.8 ± 3.2 min for males). All subjects completed a graded treadmill run during which [Vdot]O 2 and heart rate (HR) were monitored at several submaximal running speeds and at maximal exercise. Blood samples, collected at rest and 3 min after maximal exercise, were analyzed for hematocrit and hemoglobin (Hb), lactic acid (LA) and 2,3-diphosphoglyceric acid (2,3-DPG) concentrations. Body composition was assessed via hydrostatic weighing. Group comparisons revealed that the males were taller, heavier, and higher in Hb than the females (p < .05). The sexes did not differ significantly in percentage of body fat or in [Vdot]O 2 (ml · kg –1 · min –1 ), HR, respiratory exchange ratio, or ventilatory equivalent of oxygen during submaximal running or at maximal exercise (p > .05). 2,3-DPG was higher in the females when expressed relative to Hb (p < .05). These data indicate that female and male distance runners of equal performance levels are very similar in body composition and in metabolic and cardiorespiratory responses to exercise. The higher Hb observed in males may have been offset in part by the females' higher 2,3-DPG/Hb ratio.  相似文献   

20.
Abstract

Previous investigators have yielded conflicting results in testing the hypothesis that the use of toe clips during bicycle ergometry produces a higher maximal oxygen uptake ([Vdot]O 2 max) than testing without toe clips. Eight men, four competitive cyclists and four competitive distance runners volunteered to participate in three randomized [Vdot]O 2 max tests: 1) a treadmill running lest, 2) a bicycle ergometer test using standard toe clips, and 3) a test on the same ergometer without toe clips. The highest mean [Vdot]O 2 max was observed in the treadmill condition as expected. However, no statistically significant difference in mean [Vdot]O 2 max or performance time was observed between the toe-clip and no toe-clip conditions. Based on these results, the research hypothesis was rejected and no favorable physiological effect may be attributed to the use of toe clips.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号