首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 501 毫秒
1.
Abstract

The present study was designed to examine physiological responses during motocross riding. Nine Finnish A-level motocross riders performed a 15-min ride at a motocross track and a test of maximal oxygen uptake ([Vdot]O2max) in the laboratory. Cardiopulmonary strain was measured continuously during the ride as well as in the [Vdot]O2max test. During the ride, mean [Vdot]O2 was 32 ml · kg?1 · min?1 (s = 4), which was 71% (s = 12) of maximum, while ventilation (V E) was 73% (s = 15) of its maximum. The relative [Vdot]O2 and V E values during the riding correlated with successful riding performance (r = 0.80, P < 0.01 and r = 0.79, P < 0.01, respectively). Mean heart rate was maintained at 95% (s = 7) of its maximum. Mean blood lactate concentration was 5.0 mmol · l?1 (s = 2.0) after the ride. A reduction of 16% (P < 0.001) in maximal isometric handgrip force was observed. In conclusion, motocross causes riders great physical stress. Both aerobic and anaerobic metabolism is required for the isometric and dynamic muscle actions experienced during a ride.  相似文献   

2.
Abstract

The purpose of this study was to evaluate the effects of moderate- to high-intensity resistance and concurrent training on inflammatory biomarkers and functional capacity in sedentary middle-aged healthy men. Participants were selected on a random basis for resistance training (n = 12), concurrent training (n = 11) and a control group (n = 13). They performed three weekly sessions for 16 weeks (resistance training: 10 exercises with 3 × 8–10 repetition maximum; concurrent training: 6 exercises with 3 × 8–10 repetition maximum, followed by 30 minutes of walking or running at 55–85% [Vdot]O2peak). Maximal strength was tested in bench press and leg press. The peak oxygen uptake ([Vdot]O2peak) was measured by an incremental exercise test. Tumour necrosis factor-α, interleukin-6 and C-reactive protein were determined. The upper- and lower-body maximal strength increase for both resistance (+42.52%; +20.9%, respectively) and concurrent training (+28.35%; +21.5%, respectively) groups (P = 0.0001).[Vdot]O2peak increased in concurrent training when comparing pre- and post-training (P = 0.0001; +15.6%). No differences were found in tumour necrosis factor-α and interleukin-6 for both groups after the exercise. C-reactive protein increased in resistance training (P = 0.004). These findings demonstrated that 16 weeks of moderate- to high-intensity training could improve functional capacity, but did not decrease inflammatory biomarkers in middle-aged men.  相似文献   

3.
Abstract

In this study, we examined the effects of a supervised, heart rate intensity prescribed walking training programme on cardiorespiratory fitness and glycaemic control in people with type 2 diabetes mellitus. After receiving local ethics approval, 27 individuals (21 males, 6 females) with type 2 diabetes were randomly assigned to an experimental (“walking”) or control group. Participants completed a Balke-Ware test to determine peak heart rate, peak oxygen consumption ([Vdot]O2peak), and peak gradient. The walking group then completed a 7-week (four sessions a week) supervised, heart rate prescribed walking training programme, whereas the control group continued daily life. After training, participants completed another Balke-Ware test. Fasting blood glucose and glycosylated haemoglobin were measured at rest. The results showed that walking training elicited 80% (s = 2) of peak heart rate and a rating of perceived exertion of 11 (s = 1). Peak heart rate and [Vdot]O2peak were higher in the walking than in the control group after training (P < 0.05). Based on the peak gradient before training, the respiratory exchange ratio was significantly lower (P < 0.05) and there was a strong trend for [Vdot]O2 (P = 0.09) and heart rate (P = 0.09) to be lower after training at the same gradient in the walking compared with the control group. These improvements increased walking peak gradient by 5 min (s = 4 min) compared with the control (P < 0.05). There was no change in fasting blood glucose or glycosylated haemoglobin after training. Despite no change in glycaemic control, heart rate prescribed walking improved peak and sub-maximal cardiorespiratory responses. The beneficial adaptations support the use of heart rate monitoring during walking in people with type 2 diabetes mellitus.  相似文献   

4.
Abstract

Maximal oxygen uptake ([Vdot]O2max) is considered the optimal method to assess aerobic fitness. The measurement of [Vdot]O2max, however, requires special equipment and training. Maximal exercise testing with determination of maximal power output offers a more simple approach. This study explores the relationship between [Vdot]O2max and maximal power output in 247 children (139 boys and 108 girls) aged 7.9–11.1 years. Maximal oxygen uptake was measured by indirect calorimetry during a maximal ergometer exercise test with an initial workload of 30 W and 15 W · min?1 increments. Maximal power output was also measured. A sample (n = 124) was used to calculate reference equations, which were then validated using another sample (n = 123). The linear reference equation for both sexes combined was: [Vdot]O2max (ml · min?1) = 96 + 10.6 · maximal power + 3.5 · body mass. Using this reference equation, estimated [Vdot]O2max per unit of body mass (ml · min?1 · kg?1) calculated from maximal power correlated closely with the direct measurement of [Vdot]O2max (r = 0.91, P <0.001). Bland-Altman analysis gave a mean limits of agreement of 0.2±2.9 (ml · min?1 · kg?1) (1 s). Our results suggest that maximal power output serves as a good surrogate measurement for [Vdot]O2max in population studies of children aged 8–11 years.  相似文献   

5.
Abstract

The aim of this study was to assess and compare the validity of the portable VmaxST telemetry metabolic measurement device with that of a standard measurement system (Vmax29). Thirty asymptomatic, moderately active males provided written, informed consent and completed two maximal graded treadmill exercise tests (Bruce) using the VmaxST and the Vmax29 metabolic measurement systems. Tests were performed in random order on separate days to obtain peak values for time to exhaustion, heart rate, systolic and diastolic blood pressure, oxygen consumption ([Vdot]O2), carbon dioxide production ([Vdot]CO2), ventilation ([Vdot] E), and respiratory exchange ratio (RER). Multivariate analysis of variance revealed no significant main effect (P = 0.88) between the two systems across any variable, suggesting similar measurement capabilities between the two systems. Linear regression analyses revealed moderate to high coefficients of determination for [Vdot]O2 (r 2 = 0.99), [Vdot]CO2 (r 2 = 0.99), [Vdot] E (r 2 = 0.99), and RER (r 2 = 0.89). Furthermore, Bland-Altman analyses demonstrated that the VmaxST yielded similar values to the Vmax29, suggesting good agreement between the two systems. Agreement was confirmed when the differences between the methods resulted in a small range as identified by the 95% limits of agreement. Findings from the current study confirm that the VmaxST is a valid device for measuring metabolic and physiological variables during exercise within a controlled laboratory setting.  相似文献   

6.
Abstract

The aims of this study were to determine if the primary time constant (τ) for oxygen uptake ([Vdot]O2) at the onset of moderate-intensity treadmill exercise is related to endurance running performance, and to establish if τ could be considered a determinant of endurance running performance. Thirty-six endurance trained male runners performed a series of laboratory tests, on separate days, to determine maximal oxygen uptake ([Vdot]O2max), the ventilatory threshold (VT) and running economy. In addition, runners completed six transitions from walking (4 km · h?1) to moderate-intensity running (80% VT) for the determination of the [Vdot]O2 primary time constant and mean response time. During all tests, pulmonary gas-exchange was measured breath-by-breath. Endurance running performance was determined using a treadmill 5-km time-trial, after which runners were considered as combined performers (n=36) and, using a ranking system, high performers (n=10) and low performers (n=10). Relationships between τ and endurance running performance were quantified using correlation coefficients (r). Stepwise multiple regression was used to determine the primary predictor variables of endurance running performance in combined performers. Moderate correlations were observed between τ, mean response time and endurance running performance, but only for the combined performers (r=?0.55, P=0.001 and r=?0.50, P=0.002, respectively). The regression model for predicting 5-km performance did not include τ or mean response time. The velocity at [Vdot]O2max was strongly correlated to endurance running performance in all groups (r=0.72 – 0.84, P < 0.01) and contributed substantially to the prediction of performance. In conclusion, the results suggest that despite their role in determining the oxygen deficit and having a moderate relationship with endurance running performance, neither τ nor mean response time is a primary determinant of endurance running performance.  相似文献   

7.
Abstract

In this study, we examined the effects of different work:rest durations during 20 min intermittent treadmill running and subsequent performance. Nine males (mean age 25.8 years, s = 6.8; body mass 73.9 kg, s = 8.8; stature 1.75 m, s = 0.05; [Vdot]O2max 55.5 ml · kg?1 · min?1, s = 5.8) undertook repeated sprints at 120% of the speed at which [Vdot]O2max was attained interspersed with passive recovery. The work:rest ratio was constant (1:1.5) with trials involving either short (6:9 s) or long (24:36 s) work:rest exercise protocols (total exercise time 8 min). Each trial was followed by a performance run to volitional exhaustion at the same running speed. Testing order was randomized and counterbalanced. Heart rate, oxygen consumption, respiratory exchange ratio, and blood glucose were similar between trials (P > 0.05). Blood lactate concentration was greater during the long than the short exercise protocol (P < 0.05), whereas blood pH was lower during the long than the short exercise protocol (7.28, s = 0.11 and 7.30, s = 0.03 at 20 min, respectively; P < 0.05). Perceptions of effort were greater throughout exercise for the long than the short exercise protocol (16.6, s = 1.4 and 15.1, s = 1.6 at 20 min, respectively; P < 0.05) and correlated with blood lactate (r = 0.43) and bicarbonate concentrations (r = ?0.59; P < 0.05). Although blood lactate concentration at 20 min was related to performance time (r = ?0.56; P < 0.05), no differences were observed between trials for time to exhaustion (short exercise protocol: 95.8 s, s = 30.0; long exercise protocol: 92.0 s, s = 37.1) or physiological responses at exhaustion (P > 0.05). Our results demonstrate that 20 min of intermittent exercise involving a long work:rest duration elicits greater metabolic and perceptual strain than intermittent exercise undertaken with a short work:rest duration but does not affect subsequent run time to exhaustion.  相似文献   

8.
Abstract

The purpose of this study was to assess the effects of heavy resistance, explosive resistance, and muscle endurance training on neuromuscular, endurance, and high-intensity running performance in recreational endurance runners. Twenty-seven male runners were divided into one of three groups: heavy resistance, explosive resistance or muscle endurance training. After 6 weeks of preparatory training, the groups underwent an 8-week resistance training programme as a supplement to endurance training. Before and after the 8-week training period, maximal strength (one-repetition maximum), electromyographic activity of the leg extensors, countermovement jump height, maximal speed in the maximal anaerobic running test, maximal endurance performance, maximal oxygen uptake ([Vdot]O2max), and running economy were assessed. Maximal strength improved in the heavy (P = 0.034, effect size ES = 0.38) and explosive resistance training groups (P = 0.003, ES = 0.67) with increases in leg muscle activation (heavy: P = 0.032, ES = 0.38; explosive: P = 0.002, ES = 0.77). Only the heavy resistance training group improved maximal running speed in the maximal anaerobic running test (P = 0.012, ES = 0.52) and jump height (P = 0.006, ES = 0.59). Maximal endurance running performance was improved in all groups (heavy: P = 0.005, ES = 0.56; explosive: P = 0.034, ES = 0.39; muscle endurance: P = 0.001, ES = 0.94), with small though not statistically significant improvements in [Vdot]O2max (heavy: ES = 0.08; explosive: ES = 0.29; muscle endurance: ES = 0.65) and running economy (ES in all groups < 0.08). All three modes of strength training used concurrently with endurance training were effective in improving treadmill running endurance performance. However, both heavy and explosive strength training were beneficial in improving neuromuscular characteristics, and heavy resistance training in particular contributed to improvements in high-intensity running characteristics. Thus, endurance runners should include heavy resistance training in their training programmes to enhance endurance performance, such as improving sprinting ability at the end of a race.  相似文献   

9.
Abstract

The aims of this study were two-fold: (1) to consider the criterion-related validity of the multi-stage fitness test (MSFT) by comparing the predicted maximal oxygen uptake ([Vdot]O2max) and distance travelled with peak oxygen uptake ([Vdot]O2peak) measured using a wheelchair ergometer (n = 24); and (2) to assess the reliability of the MSFT in a sub-sample of wheelchair athletes (n = 10) measured on two occasions. Twenty-four trained male wheelchair basketball players (mean age 29 years, s = 6) took part in the study. All participants performed a continuous incremental wheelchair ergometer test to volitional exhaustion to determine [Vdot]O2peak, and the MSFT on an indoor wooden basketball court. Mean ergometer [Vdot]O2peak was 2.66 litres · min?1 (s = 0.49) and peak heart rate was 188 beats · min?1 (s = 10). The group mean MSFT distance travelled was 2056 m (s = 272) and mean peak heart rate was 186 beats · min?1 (s = 11). Low to moderate correlations (ρ = 0.39 to 0.58; 95% confidence interval [CI]: ?0.02 to 0.69 and 0.23 to 0.80) were found between distance travelled in the MSFT and different expressions of wheelchair ergometer [Vdot]O2peak. There was a mean bias of ?1.9 beats · min?1 (95% CI: ?5.9 to 2.0) and standard error of measurement of 6.6 beats · min?1 (95% CI: 5.4 to 8.8) between the ergometer and MSFT peak heart rates. A similar comparison of ergometer and predicted MSFT [Vdot]O2peak values revealed a large mean systematic bias of 15.3 ml · kg?1 · min?1 (95% CI: 13.2 to 17.4) and standard error of measurement of 3.5 ml · kg?1 · min?1 (95% CI: 2.8 to 4.6). Small standard errors of measurement for MSFT distance travelled (86 m; 95% CI: 59 to 157) and MSFT peak heart rate (2.4 beats · min?1; 95% CI: 1.7 to 4.5) suggest that these variables can be measured reliably. The results suggest that the multi-stage fitness test provides reliable data with this population, but does not fully reflect the aerobic capacity of wheelchair athletes directly.  相似文献   

10.
Abstract

The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6×3 min at 90% [Vdot]O2max interspersed with 6×3 min active recovery at 50% [Vdot]O2max with a 7-min warm-up and cool down at 70% [Vdot]O2max) or 50 min moderate-intensity continuous running at 70% [Vdot]O2max. Ratings of perceived enjoyment after exercise were higher (P < 0.05) following interval running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P < 0.05) ratings of perceived exertion (14 ± 1 vs. 13 ± 1). There was no difference (P < 0.05) in average heart rate (88 ± 3 vs. 87 ± 3% maximum heart rate), average [Vdot]O2 (71 ± 6 vs. 73 ± 4%[Vdot]O2max), total [Vdot]O2 (162 ± 16 vs. 166 ± 27 L) or energy expenditure (811 ± 83 vs. 832 ± 136 kcal) between protocols. The greater enjoyment associated with high-intensity interval running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.  相似文献   

11.
Abstract

Three textiles with increasing compressive surface were compared with non-compressive conventional clothing on physiological and perceptual variables during sub-maximal and maximal running. Fifteen well-trained endurance athletes (mean ± s: age 27.1 ± 4.8 years, [Vdot]O2max 63.7 ± 4.9 ml · min?1 · kg?1) performed four sub-maximal (~70%[Vdot]O2max) and maximal tests with and without different compression stockings, tights, and whole-body compression suits. Arterial lactate concentration, oxygen saturation and partial pressure, pH, oxygen uptake, and ratings of muscle soreness were recorded before, during, and after all tests. In addition, we assessed time to exhaustion. Sub-maximal (P = 0.22) and maximal oxygen uptake (P = 0.26), arterial lactate concentration (P = 0.16; 0.20), pH (P = 0.23; 0.46), oxygen saturation (P = 0.13; 0.26), and oxygen partial pressure (P = 0.09; 0.20) did not differ between the types of clothing (effect sizes = 0.00–0.45). Ratings of perceived exertion (P = 0.10; 0.15), muscle soreness (P = 0.09; 0.10) and time to exhaustion (P = 0.16) were also unaffected by the different clothing (effect sizes = 0.28–0.85). This was the first study to evaluate the effect on endurance performance of different types of compression clothing with increasing amounts of compressive surface. Overall, there were no performance benefits when using the compression garments.  相似文献   

12.
Abstract

The aim of this study was to examine the acute effects of prolonged static stretching (SS) on running economy. Ten male runners ([Vdot]O2peak 60.1 ± 7.3 ml · kg?1 · min?1) performed 10 min of treadmill running at 70%[Vdot]O2peak before and after SS and no stretching interventions. For the stretching intervention, each leg was stretched unilaterally for 40 s with each of eight different exercises and this was repeated three times. Respiratory gas exchange was measured throughout the running exercise with an automated gas analysis system. On a separate day, participants were tested for sit and reach range of motion, isometric strength and countermovement jump height before and after SS. The oxygen uptake, minute ventilation, energy expenditure, respiratory exchange ratio and heart rate responses to running were unaffected by the stretching intervention. This was despite a significant effect of SS on neuromuscular function (sit and reach range of motion, +2.7 ± 0.6 cm; isometric strength, ?5.6% ± 3.4%; countermovement jump height ?5.5% ± 3.4%; all P < 0.05). The results suggest that prolonged SS does not influence running economy despite changes in neuromuscular function.  相似文献   

13.
Abstract

The Yo-Yo intermittent endurance test is frequently used to assess aerobic endurance performance in young soccer players but only the logical validity of the test has been shown to date. The main ai m of this study was to assess the criterion (i.e. association with maximal aerobic capacity, [Vdot]O2max) and construct validities of the test in young soccer players. A secondary aim was to examine possible shared variance of the Yo-Yo intermittent endurance test with other physical capacities. Sixty-two soccer players (age 13.7±0.5 years) from an Under-14 team participated. All players performed a battery of fitness tests to assess [Vdot]O2max, aerobic endurance performance (Yo-Yo intermittent endurance test), soccer dribbling endurance performance (Hoff dribbling test), and power performance (maximal vertical jump, 30-m sprint with 10-m split time). Results showed that the Yo-Yo intermittent endurance test was strongly correlated with [Vdot]O2max (r=0.63, P<0.001), thereby showing the test's criterion validity. Players with the best performance on the Yo-Yo intermittent endurance test had significantly higher [Vdot]O2max (P<0.001, large effect), and significantly better soccer dribbling endurance (P<0.001, large effect) and 30-m sprint times (P<0.05, medium effect). Logistic regression (r=0.79, P=0.0001) showed that Hoff dribbling test performance (explained variance=50.4%), [Vdot]O2max (explained variance=39.7%), and 30-m sprint time (explained variance=14.4%) were significant independent parameters contributing to performance on the Yo-Yo intermittent endurance test. Therefore, the Yo-Yo intermittent endurance test is a valid on-field aerobic endurance performance test for young soccer players, which can also be used to differentiate the maximal aerobic capacity, soccer dribbling endurance, and 30-m sprint performance of these players.  相似文献   

14.
Abstract

In this study, we assessed the ventilatory response in 84 children (46 males: age 8.1 ± 1.0 years, body mass 34.2 ± 7.9 kg, height 1.32 ± 0.16 m; 38 females: age 8.0 ± 0.8 years, body mass 31.7 ± 8.7 kg, height 1.31 ± 0.08 m) during a cycle ergometer test to determine if there was an influence of gender on ventilatory efficiency. The test commenced at 25 W and increased by 10 W every minute. Expired air was collected through a face mask and analysed breath by breath. The ventilatory anaerobic threshold was determined according to gas exchange methods and we focused our attention on the analysis of carbon dioxide production ([Vdot]CO2), ventilation ([Vdot] E), the ratio [Vdot] E/[Vdot]CO2 and its slope. Differences between the sexes at maximal power output were strongly significant for [Vdot] E and [Vdot]CO2 (P = 0.0001 and P = 0.0004 respectively) and moderately significant for the [Vdot] E/[Vdot]CO2 ratio (P = 0.05). The slope of [Vdot] E versus [Vdot]CO2 was 30.8 ± 4.2 for males and 29.4 ± 3.2 for females, with no difference between the sexes (P = 0.1). In conclusion, although the peak values of [Vdot] E and [Vdot]CO2 were significantly different between the sexes, there were no such differences in ventilatory efficiency during a maximal incremental test expressed as the slope of [Vdot] E/[Vdot]CO2, at least in young children.  相似文献   

15.
Abstract

Nine males cycled at 53% (s = 2) of their peak oxygen uptake ([Vdot]O2peak) for 90 min (dry bulb temperature: 25.4°C, s = 0.2; relative humidity: 61%, s = 3). One litre of flavoured water at 10 (cold), 37 (warm) or 50°C (hot) was ingested 30 – 40 min into exercise. Immediately after the 90 min of exercise, participants cycled at 95%[Vdot]O2peak to exhaustion to assess exercise capacity. Rectal and mean skin temperatures and heart rate were recorded. The gradient of rise in rectal temperature was influenced (P < 0.01) by drink temperature. Mean skin temperature was highest in the hot trial (cold trial: 34.2°C, s = 0.5; warm trial: 34.4°C, s = 0.5; hot trial: 34.7°C, s = 0.6; P < 0.01). Significant differences were observed in heart rate (cold trial: 132 beats · min?1, s = 13; warm trial: 134 beats · min?1, s = 12; hot trial: 139 beats · min?1, s = 13; P < 0.05). Exercise capacity was similar between trials (cold trial: 234 s, s = 69; warm trial: 214 s, s = 52; hot trial: 203 s, s = 53; P = 0.562). The heat load and debt induced via drinking resulted in appropriate thermoregulatory reflexes during exercise leading to an observed heat content difference of only 33 kJ instead of the predicted 167 kJ between the cold and hot trials. These results suggest that there may be a role for drink temperature in influencing thermoregulation during exercise.  相似文献   

16.
Abstract

The determination of the ventilatory threshold has been a persistent problem in research and clinical practice. Several computerized methods have been developed to overcome the subjectivity of visual methods but it remains unclear whether different computerized methods yield similar results. The purpose of this study was to compare nine regression-based computerized methods for the determination of the ventilatory threshold. Two samples of young and healthy volunteers (n = 30 each) participated in incremental treadmill protocols to volitional fatigue. The ventilatory data were averaged in 20-s segments and analysed with a computer program. Significant variance among methods was found in both samples (Sample 1: F = 11.50; Sample 2: F = 11.70, P < 0.001 for both). The estimates of the ventilatory threshold ranged from 2.47 litres · min?1 (71%[Vdot]O2max) to 3.13 litres · min?1 (90%[Vdot]O2max) in Sample 1 and from 2.37 litres · min?1 (67%[Vdot]O2max) to 3.03 litres · min?1 (83%[Vdot]O2max) in Sample 2. The substantial differences between methods challenge the practice of relying on any single computerized method. A standardized protocol, likely based on a combination of methods, might be necessary to increase the methodological consistency in both research and clinical practice.  相似文献   

17.
Abstract

The purpose of this study was to establish whether critical power, as traditionally determined from the performance of three constant-load tests to exhaustion, is attained at the end of a 90-s all-out test in children. Sixteen healthy children (eight males and eight females; mean age 12.3 years, sx  = 0.1; body mass 39.6 kg, sx  = 1.8; peak [Vdot]O2 2.0 litres · min?1, sx  = 0.1) completed an incremental test to exhaustion to determine peak oxygen uptake (peak [Vdot]O2), three separate constant-load tests to exhaustion to calculate critical power, and an isokinetic 90-s all-out test. The end power of the 90-s test averaged over the last 10 s (140 W, sx  = 8) was significantly higher than critical power (105 W, sx  = 6; t = 6.8; P < 0.01), yet the two parameters were strongly correlated (r = 0.74; P < 0.01). After 60 s, there were no further reductions in power output during the 90-s test (P < 0.0001). In conclusion, at the end of a 90-s all-out test, children are able to produce power outputs well above critical power. This suggests that 90 s is not long enough to completely exhaust the anaerobic work capacity in children.  相似文献   

18.
Abstract

The main aim of this study was to determine whether the use of an imposed or freely chosen crank rate would influence submaximal and peak physiological responses during arm crank ergometry. Fifteen physically active men participated in the study. Their mean age, height, and body mass were 25.9 (s = 6.2) years, 1.80 (s = 0.10) m, and 78.4 (s = 6.1) kg, respectively. The participants performed two incremental peak oxygen consumption ([Vdot]O2peak) tests using an electronically braked ergometer. One test was performed using an imposed crank rate of 80 rev · min?1, whereas in the other the participants used spontaneously chosen crank rates. The order in which the tests were performed was randomized, and they were separated by at least 2 days. Respiratory data were collected using an on-line gas analysis system, and fingertip capillary blood samples (~20 μl) were collected for the determination of blood lactate concentration. Heart rate was also recorded throughout the tests. Time to exhaustion was measured and peak aerobic power calculated. Submaximal data were analysed using separate two-way repeated-measures analyses of variance, while differences in peak values were analysed using separate paired t-tests. Variations in spontaneously chosen crank rate were assessed using a one-way analysis of variance with repeated measures. Agreement between the crank rate strategies for the assessment of peak values was examined by calculating intra-class correlation coefficients (ICC) and 95% limits of agreement (95% LoA). While considerable between-participant variations in spontaneously chosen crank rate were observed, the mean value was not different (P > 0.05) from the imposed crank rate of 80 rev · min?1 at any point. No differences (P > 0.05) were observed for submaximal data between crank strategies. Furthermore, mean peak minute power [158 (s = 20) vs. 158 (s = 18) W], time to exhaustion [739 (s = 118) vs. 727 (s = 111) s], and [Vdot]O2peak[3.09 (s = 0.38) vs. 3.04 (s = 0.34) l · min?1] were similar for the imposed and spontaneously chosen crank rates, respectively. However, the agreement for the assessment of [Vdot]O2peak (ICC = 0.78; 95% LoA = 0.04 ± 0.50 l · min?1) between the cranking strategies was considered unacceptable. Our results suggest that either an imposed or spontaneously chosen crank rate strategy can be used to examine physiological responses during arm crank ergometry, although it is recommended that the two crank strategies should not be used interchangeably.  相似文献   

19.
Abstract

Power output and heart rate were monitored for 11 months in one female ([Vdot]O2max: 71.5 mL · kg?1 · min?1) and ten male ([Vdot]O2max: 66.5 ± 7.1 mL · kg?1 · min?1) cyclists using SRM power-meters to quantify power output and heart rate distributions in an attempt to assess exercise intensity and to relate training variables to performance. In total, 1802 data sets were divided into workout categories according to training goals, and power output and heart rate intensity zones were calculated. The ratio of mean power output to respiratory compensation point power output was calculated as an intensity factor for each training session and for each interval during the training sessions. Variability of power output was calculated as a coefficient of variation. There was no difference in the distribution of power output and heart rate for the total season (P = 0.15). Significant differences were observed during high-intensity workouts (P < 0.001). Performance improvements across the season were related to low-cadence strength workouts (P < 0.05). The intensity factor for intervals was related to performance (P < 0.01). The variability in power output was inversely associated with performance (P < 0.01). Better performance by cyclists was characterized by lower variability in power output and higher exercise intensities during intervals.  相似文献   

20.
Abstract

The aims of the study were to investigate blood lactate recovery and respiratory variables during diagonal skiing of variable intensity in skiers at different performance levels. Twelve male cross-country skiers classified as elite (n=6; [Vdot]O2max=73±3 ml · kg?1 · min?1) or moderately trained (n=6; [Vdot]O2max=61±5 ml · kg?1 · min?1) performed a 48-min variable intensity protocol on a treadmill using the diagonal stride technique on roller skis, alternating between 3 min at 90% and 6 min at 70% of [Vdot]O2max. None of the moderately trained skiers were able to complete the variable intensity protocol and there was a difference in time to exhaustion between the two groups (elite: 45.0±7.3 min; moderately trained: 31.4±10.4 min) (P<0.05). The elite skiers had lower blood lactate concentrations and higher blood base excess concentrations at all 70% workloads than the moderately trained skiers (all P<0.05). In contrast, [Vdot] E/[Vdot]O2 and [Vdot] E/[Vdot]CO2 at the 70% [Vdot]O2max workloads decreased independently of group (P<0.05). Partial correlations showed that [Vdot]O2max was related to blood lactate at the first and second intervals at 70% of [Vdot]O2max (r=?0.81 and r=?0.82; both P<0.01) but not to [Vdot] E/[Vdot]O2, [Vdot] E/[Vdot]CO2 or the respiratory exchange ratio. Our results demonstrate that during diagonal skiing of variable intensity, (1) elite skiers have superior blood lactate recovery compared with moderately trained skiers, who did not show any lactate recovery at 70% of [Vdot]O2max, suggesting it is an important characteristic for performance; and (2) the decreases in respiratory exchange ratio, [Vdot] E/[Vdot]O2, and [Vdot] E/[Vdot]CO2 do not differ between elite and moderately trained skiers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号