首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A variety of methods have been used to introduce chemicals into a stream or to mix two or more streams of different compositions using microfluidic devices. In the following paper, the introduction of cryoprotective agents (CPAs) used during cryopreservation of cells in order to protect them from freezing injuries and increase viability post thaw is described. Dimethylsulphoxide (DMSO) is the most commonly used CPA. We aim to optimize the operating conditions of a two-stream microfluidic device to introduce a 10% vol/vol solution of DMSO into a cell suspension. Transport behavior of DMSO between two streams in the device has been experimentally characterized for a spectrum of flow conditions (0.7 < Re < 10), varying initial donor stream concentrations, (1% vol/vol < Co < 15% vol/vol) and different flow rate fractions (0.23 < fq < 0.77). The outlet cell stream concentration is analyzed for two different flow configurations: one with the cell stream flowing on top of the DMSO-rich donor stream, and the other with the cell stream flowing beneath the heavy DMSO-laden stream. We establish a transition from a diffusive mode of mass transfer to gravity-influenced convective currents for Atwood numbers (At) in the range of (1.7 × 10−3 < At < 3.1 × 10−3) for the latter configuration. Flow visualization with cells further our understanding of the effect of At on the nature of mass transport. Cell motion studies performed with Jurkat cells confirm a high cell recovery from the device while underscoring the need to collect both the streams at the outlet of the device and suggesting flow conditions that will help us achieve the target DMSO outlet concentration for clinical scale flow rates of the cell suspension.  相似文献   

2.
Blood cell sorting is critical to sample preparation for both clinical diagnosis and therapeutic research. The spiral inertial microfluidic devices can achieve label-free, continuous separation of cell mixtures with high throughput and efficiency. The devices utilize hydrodynamic forces acting on cells within laminar flow, coupled with rotational Dean drag due to curvilinear microchannel geometry. Here, we report on optimized Archimedean spiral devices to achieve cell separation in less than 8 cm of downstream focusing length. These improved devices are small in size (<1 in.2), exhibit high separation efficiency (∼95%), and high throughput with rates up to 1 × 106 cells per minute. These device concepts offer a path towards possible development of a lab-on-chip for point-of-care blood analysis with high efficiency, low cost, and reduced analysis time.  相似文献   

3.
Altered vascular function and pathological angiogenesis are important factors common to the development of obesity and obesity-associated diseases. Most human studies relating obesity and angiogenesis have compared levels of angiogenic factors in obesity without looking at the serum angiogenic capacity which reflects the balance between the effects of angiogenic and angiostatic factors. Therefore, in this cross-sectional study, the serum angiogenic potential and levels of angiogenic factors in serum of obese (BMI > 25 kg/m2) and lean subjects (BMI < 23 kg/m2), with no history of obesity associated co-morbidities, were assessed. Serum angiogenic potential was significantly higher (p < 0.0001) in both male (n = 67) and female (n = 35) obese subjects and showed a positive correlation (r = 0.4, p < 0.0001) with BMI. Serum levels of the angiogenic factors, vascular endothelial growth factor (VEGF) and angiopoietin were significantly higher in obese subjects. Levels of angiostatic factors such as angiostatin, endostatin were not altered in obese male subjects but were elevated in female obese subjects. Angiogenic potential and levels of VEGF did not vary in obese subjects with high HOMA-IR compared to obese subjects with low HOMA-IR. These results suggest that the angiogenic potential of serum was elevated in obesity and that insulin resistance may not contribute to the increased angiogenic potential in obesity.  相似文献   

4.
HbA1c is used extensively for the diagnosis and management of diabetes mellitus. It constitutes 80% of glycated HbA1(Glycated haemoglobin(GHb)A), and depends upon blood glucose and RBC life span. RBC life span varies with anemia, leading to a consequent alteration in the HbA1c value irrespective of the circulating blood glucose concentration. But to the best of our knowledge no Hb cut offs have been derived for appropriate interpretation of HbA1c. The prevalence of anemia in Indian population is nearly 40% as per its definition by WHO—Hb < 12 g/dL in females and < 13 g/dL in males—with most cases attributable to nutritional deficiencies. Hence, we aimed to identify Hb cut-off for accurate interpretation of HbA1c in presence of deficiency anemias. Partial correlation between random blood glucose (RBG) and HbA1c was studied in 1312 subjects, 470 of whom had deficiency-related anemia]. The data was adjusted for age, sex and Hb. Partial correlation between RBG and HbA1c was highly significant (p < 0.0001) till Hb of 8.1 gm/dL. Significance reduced to p = 0.003 and p = 0.006 as the cut off of Hb reduced to 7.1 gm/dL and 5.0 gm/dL, respectively, but was not lost. Hence, caution in interpretation of HbA1c is not required till an Hb of 5 g/dL.  相似文献   

5.
Blood analysis plays a major role in medical and science applications and white blood cells (WBCs) are an important target of analysis. We proposed an integrated microfluidic chip for direct and rapid trapping WBCs from whole blood. The microfluidic chip consists of two basic functional units: a winding channel to mix and arrays of two-layer trapping structures to trap WBCs. Red blood cells (RBCs) were eliminated through moving the winding channel and then WBCs were trapped by the arrays of trapping structures. We fabricated the PDMS (polydimethylsiloxane) chip using soft lithography and determined the critical flow velocities of tartrazine and brilliant blue water mixing and whole blood and red blood cell lysis buffer mixing in the winding channel. They are 0.25 μl/min and 0.05 μl/min, respectively. The critical flow velocity of the whole blood and red blood cell lysis buffer is lower due to larger volume of the RBCs and higher kinematic viscosity of the whole blood. The time taken for complete lysis of whole blood was about 85 s under the flow velocity 0.05 μl/min. The RBCs were lysed completely by mixing and the WBCs were trapped by the trapping structures. The chip trapped about 2.0 × 103 from 3.3 × 103 WBCs.  相似文献   

6.
Deterministic lateral displacement (DLD) is a microfluidic size-based particle separation or filter technology with applications in cell separation and enrichment. Currently, there are no cost-effective manufacturing methods for this promising microfluidic technology. In this fabrication paper, however, we develop a simple, yet robust protocol for thermoplastic DLD devices using regulatory-approved materials and biocompatible methods. The final standalone device allowed for volumetric flow rates of 660 μl min−1 while reducing the manufacturing time to <1 h. Optical profilometry and image analysis were employed to assess manufacturing accuracy and precision; the average replicated post height was 0.48% less than the average post height on the master mold and the average replicated array pitch was 1.1% less than the original design with replicated posts heights of 62.1 ± 5.1 μm (mean ± 6 standard deviations) and replicated array pitches of 35.6 ± 0.31 μm.  相似文献   

7.
Activated carbon fabrics (ACF) mask prevents the absorption of lead and reduce its adverse effects of human health. Aim of this study to know the blood lead level and its effects on heme biosynthesis and hematological parameters after using 2 months activated carbon fabric mask of battery manufacturing workers (BMW). Blood lead level, heme biosynthesis and hematological parameters were measured by using standard method. Blood lead level (P < 0.001, − 13.5%) was significantly decreased, activated δ-aminolevulinic acid dehydratase (P < 0.001, 11.97%) and non-activated δ- aminolevulinic acid dehydratase (P < 0.001, 23.17%) enzyme activity were significantly increased, however, the ratio of activated to Non-activated δ- ALAD (P < 0.001, − 10.13%) was significantly decreased, urinary excretion of δ- aminolevulinic acid (P < 0.001, − 10.49%) and porphobilinogen (P < 0.001, − 7.38%) were significantly decreased after using 2 months ACF mask as compared to before using mask of BMW. Hematological parameters i.e Hb (P < 0.05, 13.42%), PCV (P < 0.05, 7.23%), MCV (P < 0.05, 1.9%) were significantly increased and total WBC count (P < 0.05, − 5.18%) was significantly decreased after using 2 months ACF mask as compared to before using mask of BMW. Two months using ACF mask reduces the blood lead level and improves the δ-ALDH activity and hematological parameters, decreases the urinary excretion of δ-ALA, PBG of battery manufacturing workers. Therefore, the regular using of ACF mask is beneficial to prevent the lead absorption and its adverse effects on human health.  相似文献   

8.
Label-free isolation of single cells is essential for the growing field of single-cell analysis. Here, we present a device which prints single living cells encapsulated in free-flying picoliter droplets. It combines inkjet printing and impedance flow cytometry. Droplet volume can be controlled in the range of 500 pl–800 pl by piezo actuator displacement. Two sets of parallel facing electrodes in a 50 μm × 55 μm channel are applied to measure the presence and velocity of a single cell in real-time. Polystyrene beads with <5% variation in diameter generated signal variations of 12%–17% coefficients of variation. Single bead efficiency (i.e., printing events with single beads vs. total number of printing events) was 73% ± 11% at a throughput of approximately 9 events/min. Viability of printed HeLa cells and human primary fibroblasts was demonstrated by culturing cells for at least eight days.  相似文献   

9.
Accurate measurement of blood viscoelasticity including viscosity and elasticity is essential in estimating blood flows in arteries, arterials, and capillaries and in investigating sub-lethal damage of RBCs. Furthermore, the blood viscoelasticity could be clinically used as key indices in monitoring patients with cardiovascular diseases. In this study, we propose a new method to simultaneously measure the viscosity and elasticity of blood by simply controlling the steady and transient blood flows in a microfluidic analogue of Wheastone-bridge channel, without fully integrated sensors and labelling operations. The microfluidic device is designed to have two inlets and outlets, two side channels, and one bridge channel connecting the two side channels. Blood and PBS solution are simultaneously delivered into the microfluidic device as test fluid and reference fluid, respectively. Using a fluidic-circuit model for the microfluidic device, the analytical formula is derived by applying the linear viscoelasticity model for rheological representation of blood. First, in the steady blood flow, the relationship between the viscosity of blood and that of PBS solution (μBloodPBS) is obtained by monitoring the reverse flows in the bridge channel at a specific flow-rate rate (QPBSSS/QBloodL). Next, in the transient blood flow, a sudden increase in the blood flow-rate induces the transient behaviors of the blood flow in the bridge channel. Here, the elasticity (or characteristic time) of blood can be quantitatively measured by analyzing the dynamic movement of blood in the bridge channel. The regression formula (ABlood (t) = Aα + Aβ exp [−(t − t0)/λBlood]) is selected based on the pressure difference (ΔP = PA − PB) at each junction (A, B) of both side channels. The characteristic time of blood (λBlood) is measured by analyzing the area (ABlood) filled with blood in the bridge channel by selecting an appropriate detection window in the microscopic images captured by a high-speed camera (frame rate = 200 Hz, total measurement time = 7 s). The elasticity of blood (GBlood) is identified using the relationship between the characteristic time and the viscosity of blood. For practical demonstrations, the proposed method is successfully applied to evaluate the variations in viscosity and elasticity of various blood samples: (a) various hematocrits form 20% to 50%, (b) thermal-induced treatment (50 °C for 30 min), (c) flow-induced shear stress (53 ± 0.5 mL/h for 120 min), and (d) normal rat versus spontaneously hypertensive rat. Based on these experimental demonstrations, the proposed method can be effectively used to monitor variations in viscosity and elasticity of bloods, even with the absence of fully integrated sensors, tedious labeling and calibrations.  相似文献   

10.
Human genetic adaptation to high altitudes (>2500 m) has been extensively studied over the last few years, but few functional adaptive genetic variants have been identified, largely owing to the lack of deep-genome sequencing data available to previous studies. Here, we build a list of putative adaptive variants, including 63 missense, 7 loss-of-function, 1,298 evolutionarily conserved variants and 509 expression quantitative traits loci. Notably, the top signal of selection is located in TMEM247, a transmembrane protein-coding gene. The Tibetan version of TMEM247 harbors one high-frequency (76.3%) missense variant, rs116983452 (c.248C > T; p.Ala83Val), with the T allele derived from archaic ancestry and carried by >94% of Tibetans but absent or in low frequencies (<3%) in non-Tibetan populations. The rs116983452-T is strongly and positively correlated with altitude and significantly associated with reduced hemoglobin concentration (p = 5.78 × 10−5), red blood cell count (p = 5.72 × 10−7) and hematocrit (p = 2.57 × 10−6). In particular, TMEM247-rs116983452 shows greater effect size and better predicts the phenotypic outcome than any EPAS1 variants in association with adaptive traits in Tibetans. Modeling the interaction between TMEM247-rs116983452 and EPAS1 variants indicates weak but statistically significant epistatic effects. Our results support that multiple variants may jointly deliver the fitness of the Tibetans on the plateau, where a complex model is needed to elucidate the adaptive evolution mechanism.  相似文献   

11.
We present a simple microchip device consisting of an overlaid pattern of micromagnets and microwells capable of capturing magnetically labeled cells into well-defined compartments (with accuracies >95%). Its flexible design permits the programmable deposition of single cells for their direct enumeration and pairs of cells for the detailed analysis of cell-cell interactions. This cell arraying device requires no external power and can be operated solely with permanent magnets. Large scale image analysis of cells captured in this array can yield valuable information (e.g., regarding various immune parameters such as the CD4:CD8 ratio) in a miniaturized and portable platform.The emergent need for point-of-care devices has spurred development of simplified platforms to organize cells across well-defined templates.1 These devices employ passive microwells, immunospecific adhesive islands, and electric, optical, and acoustic traps to manipulate cells.2–6 In contrast, magnetic templating can control the spatial organization of cells through its ability to readily program ferromagnetic memory states.7 While it has been applied to control the deposition of magnetic beads,8–13 it has not been used to direct the deposition of heterogeneous cell pairs, which may help provide critical insight into the function of single cells.14,15 As such, we developed a simple magnetographic device capable of arraying single cells and pairs of cells with high fidelity. We show this magnetic templating tool can use immunospecific magnetic labels for both the isolation of cells from blood and their organization into spatially defined wells.We used standard photolithographic techniques to fabricate the microchips (see supplementary material16). Briefly, an array of 10 × 30 μm cobalt micromagnets were patterned by a photolithographic liftoff process and overlaid with a pattern of dumbbell-shaped microwells formed in SU-8 photoresist (Fig. 1(a)). The micromagnets were designed to produce a predominantly vertical field in the microwells by aligning the ends of the micromagnet at the center of each well of the dumbbell. These features were deposited across an area of ≈400 mm2 (>50 000 well pairs per microchip) (Fig. 1(b)). Depending on the programmed magnetization state with respect to the external field, magnetic beads or cells were attracted to one pole and repelled by the other pole of each micromagnet, leading to a biased deposition (Fig. 1(c)).12Open in a separate windowFIG. 1.Magnetographic array for single cell analysis. (a) SEM image of the dumbbell-shaped well pairs for capturing magnetically labelled cells. (b) Photograph of the finished device. (c) An array of well pairs displaying a pitch of 60 × 120 μm before (top) and 10 min after the deposition of magnetic beads (bottom).To demonstrate the capability of the array to capture cells into a format amenable for rapid image processing, we organized CD3+ lymphocytes using only hand-held permanent magnets. We isolated CD3+ lymphocytes from blood via positive selection using anti-CD3 magnetic nanoparticles (EasySep™, STEMCELL Technologies) with purities confirmed by flow cytometry (97.8%; see supplementary material16). We then stained 1 × 106 CD3+ cells with anti-CD8 Alexa-488 and anti-CD4 Alexa-647 (5 μl of each antibody in 100 μl for 20 min; BD Bioscience) to determine the CD4:CD8 ratio, a prognostic ratio for assessing the immune system.17,18Variably spaced neodymium magnets (0.5 in. × 0.5 in. × 1 in.; K&J Magnetics, Inc.) were fixed on either side of the microchip to generate a tunable magnetic field (0–400 G; Fig. 2(a)). Using this setup, fluorescently labeled cells were deposited, and the populations of CD4+ and CD8+ cells were indiscriminately arrayed, imaged, and enumerated using ImageJ. The resulting CD4:CD8 ratio of 1.84 ± 0.18 (Fig. 2(b)) was confirmed by flow cytometry with a high correlation (5.4% difference; Fig. 2(c)), indicating the magnetographic microarray can pattern cells for the rapid and accurate assessment of critical phenotypical parameters without complex equipment (e.g., function generators or flow cytometers).Open in a separate windowFIG. 2.CD8 analysis of CD3+ lymphocytes. (a) Photograph of the magnetographic device activated by permanent magnets (covered with green tape). The CD4:CD8 ratio determined by the (b) magnetographic microarray and (c) and (d) flow cytometry was 1.84 and 1.74, respectively.More complex operations, such as the programmed deposition of cell pairs, can be achieved by leveraging the switchable, bistable magnetization of the micromagnets for the detailed studies of cell-cell interactions (Figs. 3(a)–3(d)).12 For these studies, a 200 G horizontal field generated from an electromagnetic coil was used to magnetize the micromagnets.19 We then captured different concentrations of magnetic beads as surrogates for cells (8.4 μm polystyrene, Spherotech, Inc.) and found that higher bead concentrations did not affect the capture accuracy (>95%; see supplementary material16).Open in a separate windowFIG. 3.Programmed pairing of magnetic beads and CD3+ lymphocytes. (a) Schematic of the magnetographic cell pair isolations. (b) Polarized micromagnets isolate cells of one type to one side in a vertical magnetic field and then cells of a second type to the other side when the field is reversed. (c) Fluorescent image of magnetically trapped green stained (top) and red stained (bottom) cell pairs. (d) SEM image of magnetically labeled cells in the microwells. (e) Capture accuracy of magnetic bead pairs. (Each color (and shape) represents the field strength of the reversed field.) (f) Change in the capture accuracy (loss) of initially captured beads after reversing the magnetic field. The capture accuracy of (g) magnetically labeled cell pairs and (h) the second magnetically labeled cell (for (e)–(h): n = 5; time starts from the deposition of the second set of cells or beads).The opposite side of each micromagnet was then populated with the second (yellow fluorescent) bead by reversing the direction of the applied magnetic field. We tested several field strengths (i.e., 10, 25, 40, or 55 G) to optimize the conditions for isolating the desired bead in the opposite well without ejecting the first bead. If the field strength was too large, the previously deposited beads could be ejected from their wells due to the repulsive magnetic force overcoming gravity.12 As shown in Figure 3(e), increasing the field strength from 10 to 25 G significantly increased the capture accuracy at 60 min from the deposition of the second bead (p < 0.01), but increases from 25 to 55 G did not affect the capture accuracy (p > 0.10). As shown in Figure 3(f), higher field strengths (i.e., 40 and 55 G) resulted in lower capture accuracies compared to lower field strengths (i.e., 10 and 25 G) (p < 0.01), which was primarily due to ejection of the initially captured beads when the micromagnets reversed their polarity.We then arranged pairs of membrane dyed (calcein AM, Invitrogen; PKH26, Sigma) magnetically labeled CD3+ lymphocytes. First, red stained cells (150 μl of 2 × 104 cells/ml) were deposited on the microchip in the presence of 250 G vertical magnetic field. After 20 min, the field was reversed (i.e., to 40, 55, and 70 G) and green stained cells (150 μl of 2 × 104 cells/ml) were deposited on the microchip with images taken in 10 min intervals. Fluorescence images were overlaid (Fig. 3(c)) and the capture accuracy of cell pairs was determined (ImageJ).As seen in Figure 3(g), the capture accuracy of pairs of CD3+ lymphocytes was lower than that of magnetic beads (Fig. 3(e)). However, as shown in Figure 3(h), the second set of cells (green fluorescent) exhibited an average capture accuracy of 91.8% ± 1.9%. This indicates that the lower capture accuracy of cell pairs was either due to the ejection of initially captured (red fluorescent) cells or the migration of initially captured cells through the connecting channel, resulting from their relatively high deformability compared to magnetic beads.In summary, we developed a simple device capable of organizing magnetic particles, cells, and pairs of cells into well-defined compartments. A major advantage of this system is the use of specific magnetic labels to both isolate cells and program their deposition. While the design of this device does not enable dynamic control of the spacing between captured cell pairs as does some dielectrophoresis-based devices,20 it can easily capture cells with high fidelity using only permanent magnets and has clinical relevance in the assessment of immune parameters. These demonstrations potentiate a relatively simple and robust device where highly organized spatial arrangement of cells facilitates rapid and accurate analyses towards a functional and low-cost point-of-care device.  相似文献   

12.
Assessment of the dielectrophoresis (DEP) cross-over frequency (fxo), cell diameter, and derivative membrane capacitance (Cm) values for a group of undifferentiated human embryonic stem cell (hESC) lines (H1, H9, RCM1, RH1), and for a transgenic subclone of H1 (T8) revealed that hESC lines could not be discriminated on their mean fxo and Cm values, the latter of which ranged from 14 to 20 mF/m2. Differentiation of H1 and H9 to a mesenchymal stem cell-like phenotype resulted in similar significant increases in mean Cm values to 41–49 mF/m2 in both lines (p < 0.0001). BMP4-induced differentiation of RCM1 to a trophoblast cell-like phenotype also resulted in a distinct and significant increase in mean Cm value to 28 mF/m2 (p < 0.0001). The progressive transition to a higher membrane capacitance was also evident after each passage of cell culture as H9 cells transitioned to a mesenchymal stem cell-like state induced by growth on a substrate of hyaluronan. These findings confirm the existence of distinctive parameters between undifferentiated and differentiating cells on which future application of dielectrophoresis in the context of hESC manufacturing can be based.  相似文献   

13.
The selective cell separation is a critical step in fundamental life sciences, translational medicine, biotechnology, and energy harvesting. Conventional cell separation methods are fluorescent activated cell sorting and magnetic-activated cell sorting based on fluorescent probes and magnetic particles on cell surfaces. Label-free cell separation methods such as Raman-activated cell sorting, electro-physiologically activated cell sorting, dielectric-activated cell sorting, or inertial microfluidic cell sorting are, however, limited when separating cells of the same kind or cells with similar sizes and dielectric properties, as well as similar electrophysiological phenotypes. Here we report a label-free density difference amplification-based cell sorting (dDACS) without using any external optical, magnetic, electrical forces, or fluidic activations. The conceptual microfluidic design consists of an inlet, hydraulic jump cavity, and multiple outlets. Incoming particles experience gravity, buoyancy, and drag forces in the separation chamber. The height and distance that each particle can reach in the chamber are different and depend on its density, thus allowing for the separation of particles into multiple outlets. The separation behavior of the particles, based on the ratio of the channel heights of the inlet and chamber and Reynolds number has been systematically studied. Numerical simulation reveals that the difference between the heights of only lighter particles with densities close to that of water increases with increasing the ratio of the channel heights, while decreasing Reynolds number can amplify the difference in the heights between the particles considered irrespective of their densities.Separating specific cells from heterogeneous or homogeneous mixtures has been considered as a key step in a wide variety of applications ranging from biomedicine to energy harvesting. For example, the separation and sorting of rare circulating tumor cells (CTCs) from whole blood has gained significant importance in the potential diagnosis and treatment of metastatic cancers.1,2 Similarly, malaria detection relies on the collection of infected red blood cells (RBCs) from whole blood.3,4 In addition, the selective separation of lipid-rich microalgae from homogeneous mixtures of microalgae is a promising technique in biomass conversion.5To date, conventional cell separation can be done by labelling cells with biomolecules to induce differences in physical properties. For instance, in a fluorescence-activated cell sorter (FACS), cells to be separated are labelled with antibodies or aptamers with fluorescent molecules, and then sorted by applying an electrical potential.6,7 Similarly, magnetic-activated cell sorter (MACS) uses magnetic.8,9 Alternatively, label-free cell separation methods have exploited inherent differences in the physical properties (e.g., size and dielectric properties) of different kinds of cells. For example, acoustophoresis forces particles larger than a desired size to move into the center of a fluidic channel by using ultrasonic standing waves.10–12 Inertial microfluidics takes advantage of curved fluidic channels in order to amplify the size differences between particles.13,14 Mass-dependent separation of particles based on gravity and hydrodynamic flow was also reported.15 Particles with different dielectric properties can also be sorted by dielectrophoresis which induces the movement of polarizable particles.16–18The disadvantage of these methods, however, is that they require external forces and labels that may cause unexpected damage to biological cells.19–21 More importantly, most methods are limited in separating cells of the same kind or cells with similar sizes and dielectric properties.Here we designed a novel, label-free density difference amplification-based cell sorting (dDACS) that allows the separation of particles with the same size and charge by exploiting subtle differences in density without the use of external forces. Figure 1(a) illustrates the proposed microfluidic model and its underlying mechanism. The conceptual microfluidic system consists of an inlet, a separation chamber (hydraulic jump cavity), and multiple outlets. Particles entering through the inlet experience gravity (FG), buoyancy (FB), and drag (FD) forces in the separation chamber. The net force acting on the particles can be described as FFGFBFD.(1)As particles enter the separation chamber (i.e., hydraulic jump cavity), FD acting on the particles changes its direction along the streamline. The particles experience additional forces in the y direction due to large tangential angle (Fig. 1(b)). For lighter particles, whose densities are close to that of the surrounding water, FD becomes comparable to FG (i.e., in the y direction), while the net force for heavier particles is less affected by this additional contribution of FD due to a large FG. As a result, the height (H) and distance (D) that each particle can travel are different depending on its density. The difference in the maximum height (ΔHmax) between two particles with different density (ρp1 and ρp2) can be further approximated as ΔHmax(vyp0)2(vyfvyp0),(ρp1ρp2),(2)where vyp0 and vyf represent the velocity of particle and fluid along the y direction at the entrance of hydraulic jump cavity, respectively.Open in a separate windowFIG. 1.Schematic illustration of label-free density difference amplification-based cell sorting (dDACS), which exploits differences in the densities (ρ1 > ρ2) of particles with similar diameters (d) and charge. (a) The conceptual microfluidic design consists of an inlet, a separation chamber (hydraulic jump cavity), and multiple outlets. Incoming particles experience gravity (FG), buoyancy (FB), and drag (FD) forces in the separation chamber, and depending on their densities, the height (H) and distance (D) that each particle is able to reach will be different, allowing the particles to be separated into multiple outlets. (b) Possible microfluidic channel configurations for density-based separation: Uniform channel height (left), gradual channel expansion (middle), and hydraulic jump cavity with sudden channel expansion (right). The height difference between particles with different densities can be amplified by the sudden channel expansion compared to the other two cases due to the relatively large tangential angle, θ of FD. (|θ1|≪ |θ2|) (see Fig. S1 in the supplementary material22).In comparison with the other two cases (Fig. 1(b) uniform channel height and gradual channel expansion), the height difference between the particles with different densities can be amplified by the sudden channel expansion in the hydraulic jump cavity due to relatively large tangential angle (see supplementary material22). Therefore, the particles can be separated through the multiple outlets, depending on their height and distance.In order to analyze the separation behavior of particles in the chamber according to differences in their densities, H and D are systematically investigated. The numerical simulations are performed using a commercial CFD software (CFX 14.0; ANSYS 14.0; ANSYS, Inc.). Particles with the same density may have different trajectories in the separation chamber depending on their inlet positions (Fig. 2(a)). Prior to this investigation, the maximum height (Hmax) and distance (Dmax) for each particle are compared by examining H and D of 100 identical particles at different inlet positions since the inlet position of particles could be controlled.20 Fig. 2(b) shows Hmax and Dmax of particles with respect to density at a fixed Reynolds number (Re = 0.1). Note that Reynolds number is defined as Re = ρfvfDh/μ, where ρf, vf, Dh, μ are density of fluid, velocity of the fluid, hydraulic diameter of a channel, and dynamic viscosity of the fluid, respectively. The hydraulic diameter in the Reynolds number is determined with the inlet channel. Particle densities in the range of 1.1 to 2.0 g/cm3 are chosen with the increase of 0.1 g/cm3. These values are quite reasonable in that the densities of many microorganisms such as microalgae are typically within this range and their densities can be varied by 0.2 g/m3 depending on their cellular context.23 The lighter particles travel with a higher Hmax, and longer Dmax. With the separation chamber, the height difference between particles with densities of 1.1 and 1.2 g/cm3 can be amplified by about 10 times as compared to that in a channel without the chamber, judging from the position where the 1.1 g/cm3 particle reaches its Hmax.Open in a separate windowFIG. 2.Microfluidic particle separation with respect to Reynolds number (Re). (a) Trajectories in the separation chamber of a hundred particles with the same density starting from inlet positions chosen arbitrarily in order to investigate the effect of the inlet positions on the maxima of the height (Hmax) and distance (Dmax) prior to further simulation. (b) Representative trajectories of particles having different densities from 1.1 to 2.0 g/cm3. (c) The maximum height (Hmax) of each particle with respect to Re. (d) Representative maximum distance (Dmax) of each particle at Re = 0.1. (Left) Streamline of fluid and representative trajectories of particles with densities of 1.1 and 2.0 g/cm3 in the separation chamber at Re = 0.1 (right).In Fig. 2(c), the values for Hmax of particles with respect to Reynolds number (Re) are presented. Since in our study, the maximum height (Hmax) and distance (Dmax) for each particle were compared by examining H and D of 100 identical particles that are randomly distributed in the channel (throughout all figures), there is little variation in Hmax and Dmax between each simulation. However, the standard deviation between each simulation is quite small and can be negligible. The Hmax values particles at Re = 0.5 with densities of 1.1 g/cm3 and 1.2 g/cm3 are 2.21 × 103 μm and 2.17 × 103 μm, respectively. The difference between Hmax of different particles, ΔHmax, increases with decreasing Re. For example, ΔHmax between particles with densities of 1.1 and 2.0 g/cm3 becomes 0.26 × 103 μm at Re = 1.0, but increases to 1.38 × 103 μm as Re decreases to 0.1. As Re increases (velocity of fluid increases), the relative velocity in the y direction between the fluid and the particle increases resulting in increasing of FD in the y direction since the velocity of particle in the y direction is very small at the entrance of the separation chamber. Thus, contribution of FD becomes comparable to the net force in the y direction. As a result, most of the particles even in the case of heavier ones travel quite similarly with the streamline, and ΔHmax subsequently decreases. On the other hand, as Re decreases, the contribution of FG becomes dominant due to the decrease of FD in the y direction. Consequently, the particles start to cross downwards streamlines as the density of the particles increases and Hmax gradually decreases. In addition, irrespective of their densities, ΔHmax of the particles increases with decreasing Re.Fig. 2(d) shows Dmax with respect to the density of the particles (left). Different densities of particles show different trajectories due to the relative contribution of FD to the net force in the y direction depending on the particle density (right). At Re = 0.1, Dmax of particles with densities of 1.1 cm3 and 1.2 g/cm3 are 2.91 × 104 μm and 1.43 × 104 μm, respectively. As the density of a particle increases, its Dmax dramatically decreases. The difference in Dmax between particles with densities of 1.1 and 1.2 g/cm3 is 1.48 × 104 μm, and 0.0037 × 104 μm for particles with densities of 1.9 and 2.0 g/cm3. The effect of FD is stronger compared to that of FG on lighter particles. Thus, lighter particles travel quite similarly with the streamline and finally have a large Dmax. On the other hand, heavier particles where effect of FG is stronger compared to that of FD cross downwards streamlines and finally have a small Dmax.Next, in order to investigate the separation behavior of particles with respect to the geometry of the microfluidic device, the effect of the ratio of the height of the separation chamber (hc) to the inlet (hi) on Hmax is investigated as shown in Fig. Fig.3.3. Interestingly, Hmax of particles with density of 1.1 g/cm3 increases from 1.93 × 103 μm to 6.48 × 103 μm while that of particles with density of 1.9 g/cm3 slightly changes from 0.70 × 103 μm to 0.73 × 103 μm as hc/hi increases from 5 to 20.Open in a separate windowFIG. 3.Microfluidic particle separation with respect to the ratio of the height of the inlet (hi) to the separation chamber (hc).This result can be attributed to two effects: (1) the change in the streamline and (2) the relative contribution of drag force to the net force depending on the density. With increasing hc/hi, dramatic increase in Hmax for lighter particles is because the streamline for the lighter ones experiences more vertical displacement in the separation chamber and the contribution of FD to the net force acting on the lighter one is more significant (see Fig. S2 in the supplementary material22).Based on this approach, we propose a microfluidic device for the selective separation of the lightest particle. Fig. 4(a) shows one unit (with three outlets) of the proposed microfluidic device that can be connected in series. The ratio of channel heights (hc/hi) is set to 20, and the particle densities are in the range of 1.1 ∼ 1.5 g/m3. Fig. 4(b) shows the representative separation behavior of the particles. A portion of the lightest particles (1.1 g/cm3) is selectively separated into the upper and middle outlets, while remaining light particles together with four other heavier particles with densities in the range of 1.2 to 1.5 g/cm3 leave through the lowest outlet. With a single operation of this unit, 40% of the lightest particles are recovered. In addition, the yield increases with increasing number of cycles (Fig. 4(c)).Open in a separate windowFIG. 4.(a) One unit of the proposed microfluidic device for the selective separation of the lightest particle based on the simulation results. Particles are separated into two outlets based on differences in both the height and distance travelled stemming from differences in density. (b) Representative separation behavior of particles observed in the device. (c) The yield of the lightest particle (1.1 g/cm3) with the proposed microfluidic device according to the number of cycles (i.e., this unit is assumed to be connected in series).In summary, we have demonstrated a label-free microfluidic system for the separation of particles according to subtle differences in their densities without external forces. Our microfluidic design consists simply of an inlet, a separation chamber, and multiple outlets. When entering the separation chamber, the particles experience an additional drag force in the y direction, amplifying the difference in both the height and the distance that the particles with different densities can travel within the chamber. At a fixed Reynolds number, with increasing particle density, Hmax decreases monotonously, and Dmax decreases dramatically. On the other hand, as Reynolds number increases, the difference between the heights of particles with different densities is attenuated. In addition, the simulation reveals that increasing the ratio of the channel heights increases the difference between the heights of particles only when their densities are close to that of the surrounding water. Based on this approach, a microfluidic device for the separation of the lightest particles has been proposed. We expect that our density-based separation design can be beneficial to the selective separation of specific microorganisms such as lipid-rich microalgae for energy harvesting application.  相似文献   

14.
Isolation and enumeration of circulating tumor cells (CTCs) are used to monitor metastatic disease progression and guide cancer therapy. However, currently available technologies are limited to cells expressing specific cell surface markers, such as epithelial cell adhesion molecule (EpCAM) or have limited specificity because they are based on cell size alone. We developed a device, ApoStream that overcomes these limitations by exploiting differences in the biophysical characteristics between cancer cells and normal, healthy blood cells to capture CTCs using dielectrophoretic technology in a microfluidic flow chamber. Further, the system overcomes throughput limitations by operating in continuous mode for efficient isolation and enrichment of CTCs from blood. The performance of the device was optimized using a design of experiment approach for key operating parameters such as frequency, voltage and flow rates, and buffer formulations. Cell spiking studies were conducted using SKOV3 or MDA-MB-231 cell lines that have a high and low expression level of EpCAM, respectively, to demonstrate linearity and precision of recovery independent of EpCAM receptor levels. The average recovery of SKOV3 and MDA-MB-231 cancer cells spiked into approximately 12 × 106 peripheral blood mononuclear cells obtained from 7.5 ml normal human donor blood was 75.4% ± 3.1% (n = 12) and 71.2% ± 1.6% (n = 6), respectively. The intra-day and inter-day precision coefficients of variation of the device were both less than 3%. Linear regression analysis yielded a correlation coefficient (R2) of more than 0.99 for a spiking range of 4–2600 cells. The viability of MDA-MB-231 cancer cells captured with ApoStream was greater than 97.1% and there was no difference in cell growth up to 7 days in culture compared to controls. The ApoStream device demonstrated high precision and linearity of recovery of viable cancer cells independent of their EpCAM expression level. Isolation and enrichment of viable cancer cells from ApoStream enables molecular characterization of CTCs from a wide range of cancer types.  相似文献   

15.
Nowadays, microfluidics is attracting more and more attentions in the biological society and has provided powerful solutions for various applications. This paper reported a microfluidic strategy for aqueous sample sterilization. A well-designed small microchannel with a high hydrodynamic resistance was used to function as an in-chip pressure regulator. The pressure in the upstream microchannel was thereby elevated which made it possible to maintain a boiling-free high temperature environment for aqueous sample sterilization. A 120 °C temperature along with a pressure of 400 kPa was successfully achieved inside the chip to sterilize aqueous samples with E. coli and Staphylococcus aureus inside. This technique will find wide applications in portable cell culturing, microsurgery in wild fields, and other related micro total analysis systems.Microfluidics, which confines fluid flow at microscale, attracts more and more attentions in the biological society.1–4 By scaling the flow domain down to microliter level, microfluidics shows attractive merits of low sample consumption, precise biological objective manipulation, and fast momentum/energy transportation. For example, various cell operations, such as culturing5–7 and sorting,8–10 have already been demonstrated with microfluidic approaches. In most biological applications, sterilization is a key sample pre-treatment step to avoid contamination. However, as far as the author knew, this important pre-treatment operation is generally achieved in an off-chip way, by using high temperature and high pressure autoclave. Actually, microfluidics has already been utilized to develop new solution for high pressure/temperature reactions. The required high pressure/temperature condition was generated either by combining off-chip back pressure regulator and hot-oil bath,11,12 or by integrating pressure regulator, heater, and temperature sensor into a single chip.13 This work presented a microfluidic sterilization strategy by implementing the previously developed continuous flowing high pressure/temperature microfluidic reactor.Figure Figure11 shows the working principle of the present microfluidic sterilization chip. The chip consists of three zones: sample loading (a microchannel with length of 270 mm and width of 40 μm), sterilization (length of 216 mm and width of 100 μm), and pressure regulating (length of 42 mm and width of 5 μm). Three functional zones were separated by two thermal isolation trenches. The sample was injected into the chip by a syringe pump and experienced two-step filtrations (feature sizes of 20 μm and 5 μm, not shown in Figure Figure1)1) at the entrance to avoid the channel clog. All channels had the same depth of 40 μm. According to the Hagen–Poiseuille relationship,15 the pressure regulating channel had a large flow resistance (around 1.09 × 1017 Pa·s/m3, see supplementary S1 for details16) because of its small width, thereby generated a high working pressure in the upstream sterilization channel under a given flow rate. The boiling point of the solution will then be raised up by the elevated pressure in the sterilization zone followed by the Antoine equation.16 By integrating heater/temperature sensors in the pressurized zone, a high temperature environment with temperature higher than 100 °C can thereby be realized for aqueous sample sterilization. The sample was collected from the outlet and cultured at 37 °C for 12 h. Bacterial colony was counted to evaluate the sterilization performance.Open in a separate windowFIG. 1.Working principle of the present microfluidic sterilization. Only microfluidic channel, heater, and temperature sensor were schematically shown. The varied colour of the microchannel represents the pressure and that of the halation stands for the temperature.Fabrication of this chip has been introduced elsewhere.14 The fabricated chip and the experimental system are shown in Figure Figure2.2. There were two inlets of the chip. While, in the experiment, only one inlet used and connected to the syringe pump. The backup one was blocked manually. The sample load zone was arranged in between of the sterilization zone and the pressure regulating zone based on thermal management consideration. A temperature control system (heater/temperature sensor, power source, and multi-meter) was setup to provide the required high temperature. The heater and the temperature sensor were microfabricated Pt resistors. The temperature coefficient of resistance (TCR) was measured as 0.00152 K−1.Open in a separate windowFIG. 2.The fabricated chip and the experimental system. (a) Two chips with a penny for comparison. The left chip was viewed from the heater/temperature sensor side, while the right one was observed from the microchannel side (through a glass substrate). (b) The experimental system.Thermal isolation performance of the present chip before packaging with inlet/outlet was shown in Figure Figure3,3, to show the thermal interference issue. The results indicated that when the sterilization zone was heated up to 140 °C, the pressure regulating zone was about 40 °C. At this temperature, the viscosity of water decreases to 0.653 mPa·s from 1.00 mPa·s (at 20 °C), which will make the pressure in the sterilization zone reduced from 539 kPa (calculated at 20 °C and flow rate of 4 nl/s) to 387 kPa. The boiling point will then decrease to 142.8 °C, which will guarantee a boiling-free sterilization. In the cases without the thermal isolation trenches, the temperature of the pressure regulating zone reached as high as 75 °C because of the thermal interference from the sterilization zone, as shown in Figure Figure3.3. The pressure in the sterilization zone was then reduced to 268 kPa (calculated at flow rate of 4 nl/s) and the boiling temperature was around 130 °C, which was lower than the set sterilization temperature. Detail calculation can be found in supplementary S2.16Open in a separate windowFIG. 3.The temperature distribution of the chips (before packaged) with and without thermal isolation trenches (powered at 1 W). The data were extracted from the central lines of infrared images, as shown as inserts.Bacterial sterilization performance of the present chip was tested and the experimental results were shown in Figure Figure4.4. E. coli with initial concentration of 106/ml was pumped into and flew through the chip with the sterilization temperatures varied from 25 °C to 120 °C at flow rates of 2 nl/s and 4 nl/s. The outflow was collected and inoculated onto the SS agar plate evenly with inoculation loops. The population of bacteria in the outflow was counted based on the bacterial colonies after incubation at 37 °C for 12 h. Typical bacterial colonies were shown in Figure Figure4.4. The low flow rate case showed a better sterilization performance because of the longer staying period in the sterilization channel. The population of E. coli was around 1.25 × 104/ml after a 432 s-long, 70 °C sterilization (at flow rate of 2 nl/s). While at the flow rate of 4 nl/s, the cultivation result indicated the population was around 3.8 × 104/ml because the sterilization time was shorten to 216 s. A control case, where the solution flew through an un-heated chip at 2 nl/s, was conducted to investigate the effect of the shear stress on the sterilization performance (see the supplementary S3 for details16). As listed in Table TableI,I, the results indicated that the shear stress did not show any noticeable effect on the bacterial sterilization. When the chip was not heated, i.e., the case with the largest shear stress because of the highest viscosity of fluid, the bacterial cultivation was nearly the same as the off-chip results (no stress). The temperature has the most significant effect on the sterilization performance. No noticeable bacteria proliferation was observed in the cases with the sterilization temperature higher than 100 °C, as shown in Figure Figure44.

Table I.

The E. coli cultivation results under different flow rates and sterilization temperatures. a
 25 °C70 °C100 °C120 °C25 °C b
2 nl/s1.89/+++1.38/+1.16/−1.04/−0/+++
4 nl/s3.78/+++2.76/+2.32/−2.08/−0/+++
Open in a separate windowaData in the table are shear stress (Pa)/population of bacteria, where “+++” indicates a large proliferation, “+” means small but noticeable proliferation, “−” represents no proliferation.bOff-chip control group.Open in a separate windowFIG. 4.Sterilization performance of the present chip with E. coli and S. aureus as test bacteria. All the original population was 106/ml. Inserted images showed the images of the culture disk after bacteria incubation.Sterilization of another commonly encountered bacterium, Staphylococcus aureus, with initial population of 106/ml was also tested in the present chip, as shown in Figure Figure4.4. Similarly, no noticeable S. aureus proliferation was found when the sterilization temperature was higher than 100 °C.In short, we demonstrated a microfluidic sterilization strategy by utilizing a continuous flowing high temperature/pressure chip. The population of E. coli or S. aureus was reduced from 106/ml to an undetectable level when the sterilization temperature of the chip was higher than 100 °C. The chip holds promising potential in developing portable microsystem for biological/clinical applications.  相似文献   

16.
Acoustic trapping of minute bead amounts against fluid flow allows for easy automation of multiple assay steps, using a convenient aspirate/dispense format. Here, a method based on acoustic trapping that allows sample preparation for immuno-matrix-assisted laser desorption/ionization mass spectrometry using only half a million 2.8 μm antibody covered beads is presented. The acoustic trapping is done in 200 × 2000 μm2 glass capillaries and provides highly efficient binding and washing conditions, as shown by complete removal of detergents and sample processing times of 5-10 min. The versatility of the method is demonstrated using an antibody against Angiotensin I (Ang I), a peptide hormone involved in hypotension. Using this model system, the acoustic trapping was efficient in enriching Angiotensin at 400 pM spiked in plasma samples.  相似文献   

17.
We present an optofluidic microvalve utilizing an embedded, surface plasmon-enhanced fiber optic microheater. The fiber optic microheater is formed by depositing a titanium thin film on the roughened end-face of a silica optical fiber that serves as a waveguide to deliver laser light to the titanium film. The nanoscale roughness at the titanium-silica interface enables strong light absorption enhancement in the titanium film through excitation of localized surface plasmons as well as facilitates bubble nucleation. Our experimental results show that due to the unique design of the fiber optic heater, the threshold laser power required to generate a bubble is greatly reduced and the bubble growth rate is significantly increased. By using the microvalve, stable vapor bubble generation in the microchannel is demonstrated, which does not require complex optical focusing and alignment. The generated vapor bubble is shown to successfully block a liquid flow channel with a size of 125 μm × 125 μm and a flow rate of ∼10 μl/min at ∼120 mW laser power.  相似文献   

18.
Sodium-based dual-ion batteries (Na-DIBs) show a promising potential for large-scale energy storage applications due to the merits of environmental friendliness and low cost. However, Na-DIBs are generally subject to poor rate capability and cycling stability for the lack of suitable anodes to accommodate large Na+ ions. Herein, we propose a molecular grafting strategy to in situ synthesize tin pyrophosphate nanodots implanted in N-doped carbon matrix (SnP2O7@N-C), which exhibits a high fraction of active SnP2O7 up to 95.6 wt% and a low content of N-doped carbon (4.4 wt%) as the conductive framework. As a result, this anode delivers a high specific capacity ∼400 mAh g−1 at 0.1 A g−1, excellent rate capability up to 5.0 A g−1 and excellent cycling stability with a capacity retention of 92% after 1200 cycles under a current density of 1.5 A g−1. Further, pairing this anode with an environmentally friendly KS6 graphite cathode yields a SnP2O7@N-C||KS6 Na-DIB, exhibiting an excellent rate capability up to 30 C, good fast-charge/slow-discharge performance and long-term cycling life with a capacity retention of ∼96% after 1000 cycles at 20 C. This study provides a feasible strategy to develop high-performance anodes with high-fraction active materials for Na-based energy storage applications.  相似文献   

19.
For the first time, we report on the preliminary evaluation of gold coated optical fibers (GCOFs) as three-dimensional (3D) electrodes for a membraneless glucose/O2 enzymatic biofuel cell. Two off-the-shelf 125 μm diameter GCOFs were integrated into a 3D microfluidic chip fabricated via rapid prototyping. Using soluble enzymes and a 10 mM glucose solution flowing at an average velocity of 16 mm s−1 along 3 mm long GCOFs, the maximum power density reached 30.0 ± 0.1 μW cm−2 at a current density of 160.6 ± 0.3 μA cm−2. Bundles composed of multiple GCOFs could further enhance these first results while serving as substrates for enzyme immobilization.  相似文献   

20.
This study reports a robust method of gene transfection in a murine primary cell model by using a high-density electrodes network (HDEN). By demonstrating high cell viability after gene transfection and successful expression of transgenes including fluorescent proteins, the HDEN device shows great promise as a solution in which reprogramming efficiency using non-viral induction for generation of murine induced pluripotent stem cells (iPSCs) is optimized. High and steady transgene expression levels in host cells of iPSCs can be demonstrated using this method. Moreover, the HDEN device achieved successful gene transfection with a low voltage of less than 180 V while requiring relatively low cell numbers (less than 1.5 × 104 cells). The results are comparable to current conventional methods, demonstrating a reasonable fluorescent-plasmid transfection rate (42.4% in single transfection and 24.5% in triple transfection) and high cell viability of over 95%. The gene expression levels of each iPSC factor was measured to be over 10-fold higher than that reported in previous studies using a single mouse embryonic fibroblast cell. Our results demonstrate that the generation of iPSCs using HDEN transfection of plasmid DNA may be a feasible and safe alternative to using viral transfection methods in the near future.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号