首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
The accuracy of video analysis of the passive straight-leg raise test (PSLR) and the validity of the sit-and-reach test (SR) were tested in 60 men and women. Computer software measured static hip-joint flexion accurately. High within-session reliability of the PSLR was demonstrated (R > .97). Test-retest (separate days) reliability for SR was high in men (R = .97) and women R = .98) moderate for PSLR in men (R = .79) and women (R = .89). SR validity (PSLR as criterion) was higher in women (Day 1, r = .69; Day 2, r = .81) than men (Day 1, r = .64; Day 2, r = .66). In conclusion, video analysis is accurate and feasible for assessing static joint angles, PSLR and SR tests are very reliable methods for assessing flexibility, and the SR validity for hamstring flexibility was found to be moderate in women and low in men.  相似文献   

2.
Head rotation, shoulder extension and rotation, ankle plantar and dorsiflexion, hip flexion, and sit and reach (SR) scores were examined in 41 women and 39 men, aged 45-75 years. The SR gave more reproducible data than the other measurements (intraclass test/retest correlation over 8 months, r = .83). SR scores were independent of standing height (r2 = .068) but were greater in women (p less than .002). The flexibility at all joints was less than reported for young adults. There were age-related decreases of flexibility scores for the head and shoulder joints (p less than .01), with a parallel trend (p less than .05) for ankle plantar flexion and SR scores (the last only after inclusion of an age-gender interaction term). A principal components analysis identified three factors (tentatively identified as general trunk, ankle, and shoulder flexibility) accounting for 55.9% of total variance. SR scores had a moderate correlation with the first factor (r = .61) but only weak correlations with the second and third. Although the SR test is the most reliable simple instrument, it provides only limited information about the flexibility at other joints in an older population.  相似文献   

3.
The purpose of the study was to examine the norm-referenced and criterion-referenced reliability and validity of the Back-Saver Sit-and-Reach Test (BSR; Single-Leg Sit-and-Reach; Cooper Institute for Aerobics Research [CIAR], 1999). One hundred seventy-nine elementary school children (87 boys and 92 girls), 6-12 years old participated, with 44 randomly selected participants retested on a second day. The BSR, Modified Schober (MSCH, Low Back Criterion Test), Passive Straight Leg Raise (PSLR, Hamstring Criterion Test), Active Knee Extension, True Lumbar Extension, True Lumbar Flexion, and Double-Leg Sit-And-Reach were administered in random order. Intraclass correlation coefficients (norm-referenced reliability) for the BSR were extremely high (.98-.99) for both boys and girls. Pa and Km (criterion-referenced test-retest reliability) for the right leg was .90 and .80, respectively, for boys; and .91 and .82 for girls, indicating the participants were classified consistently across days. Norm-referenced validity coefficients (Pearson product-moment correlations, r) of the BSR as a measure of hamstring flexibility were moderate for boys (.67 and .68, right and left legs, respectively) and moderately low for girls (.47 and .44, right and left legs). Correlation coefficients of the BSR as a measure of low back flexibility were extremely poor for boys and girls, with coefficients ranging from .003 to .06. Criterion-referenced validity of BSR for hamstring flexibility was low and unacceptable for right and left legs (Km: .48, .58, respectively), for both boys and girls (Km: .40, .22). The BSR appears to be similar to the Double-Leg Sit-and-Reach in that it is a test of hamstring flexibility but not low back. The criterion-referenced standards for both BSR and PSLR should be re-examined and adjusted to provide a better degree of classification agreement between the BSR and the criterion measure (PSLR).  相似文献   

4.
Abstract

Head rotation, shoulder extension and rotation, ankle plantar and dorsiflexion, hip flexion, and sit and reach (SR) scores were examined in 41 women and 39 men, aged 45–75 years. The SR gave more reproducible data than the other measurements (intraclass test/retest correlation over 8 months, r = .83). SR scores were independent of standing height (r 2 = .068) but were greater in women (p < .002). The flexibility at all joints was less than reported for young adults. There were age-related decreases of flexibility scores for the head and shoulder joints (p < .01), with a parallel trend (p < .05) for ankle plantar flexion and SR scores (the last only after inclusion of an age-gender interaction term). A principal components analysis identified three factors (tentatively identified as general trunk, ankle, and shoulder flexibility) accounting for 55.9% of total variance. SR scores had a moderate correlation with the first factor (r = .61) but only weak correlations with the second and third. Although the SR test is the most reliable simple instrument, it provides only limited information about the flexibility at other joints in an older population.  相似文献   

5.
Measuring lower body strength is critical in evaluating the functional performance of older adults. The purpose of this study was to assess the test-retest reliability and the criterion-related and construct validity of a 30-s chair stand as a measure of lower body strength in adults over the age of 60 years. Seventy-six community-dwelling older adults (M age = 70.5 years) volunteered to participate in the study, which involved performing two 30-s chair-stand tests and two maximum leg-press tests, each conducted on separate days 2-5 days apart. Test-retest intraclass correlations of .84 for men and .92 for women, utilizing one-way analysis of variance procedures appropriate for a single trial, together with a nonsignificant change in scores from Day 1 testing to Day 2, indicate that the 30-s chair stand has good stability reliability. A moderately high correlation between chair-stand performance and maximum weight-adjusted leg-press performance for both men and women (r = .78 and .71, respectively) supports the criterion-related validity of the chair stand as a measure of lower body strength. Construct (or discriminant) validity of the chair stand was demonstrated by the test's ability to detect differences between various age and physical activity level groups. As expected, chair-stand performance decreased significantly across age groups in decades--from the 60s to the 70s to the 80s (p < .01) and was significantly lower for low-active participants than for high-active participants (p < .0001). It was concluded that the 30-s chair stand provides a reasonably reliable and valid indicator of lower body strength in generally active, community-dwelling older adults.  相似文献   

6.
To examine the reliability for peak responses of oxygen consumption (VO2peak) in relative (ml · kg-1 · min-1) and absolute (L/min-1) measures, as well as peak heart rate (HRpeak) during deep water running (DWR), 26 participants (12 women, 14 men) completed two DWR maximal graded exercise tests. To estimate the validity of the peak responses during DWR, a comparison to a treadmill running (TMR) graded exercise test (GXT) was completed. Test order was randomized. The DWR GXT utilized a system of weights and pulleys to increase intensity of exercise. Reliability of the DWR test for the total group was estimated using a repeated measures one-way analysis of variance (ANOVA) for VO2peak (ml · kg-1 · min-1, R = .96; L/min-1, R = .97) and HRpeak (R = .90). There were no significant differences (p > .05) between the two DWR tests for men or women for the means of VO2peak in relative units (men: 50.5 vs. 52.0 ml · kg-1 · min-1; women: 37.1 vs. 36.8 ml · kg-1 · min-1), or absolute units (men: 4.1 vs. 4.1 L/min-1; women: 2.2 vs. 2.2 L/min-1), or HR (men: 174 vs. 175 beats per minute (bpm); women: 181 vs. 183 bpm). There was a significant correlation between the average of the two DWR tests and TMR for the total group for VO2peak for relative (r = .88, p = .001) and absolute (r = .93, p = .001) measures as well as HRpeak (r = .64, p = .001). Peak responses during the DWR protocol were judged to be reliable. Also, the correlation for the variables between DWR and TMR indicates a positive relation between peak responses. The correlation suggests validity of predicting TMR peak responses from DWR peak responses; however, this conclusion may be questionable due to the low sample size and the large systemic differences between tests. Finally, HRpeak and VO2peak were lower during DWR than TMR for both men and women.  相似文献   

7.
The purpose of this study was to examine the psychometric properties of child- and teacher-reported curl-up (CU) scores in children ages 10-12 years in both a norm-referenced (NR) and criterion-referenced (CR) framework. Eighty-four children, 36 boys and 48 girls, performed the FITNESSGRAM (Cooper Institute for Aerobics Research, 1992) CU test on 2 days separated by 48-72 hr. Two video cameras were used to record students' CU performances. Two students performed the CU at the same time, with each child's performance recorded by one camera. The test was terminated when the child stopped due to fatigue or after two form errors occurred. Teacher-reported scores were the average of two independent ratings of each video performance, while child-reported scores came from data collected and recorded by the children. Single trial norm-referenced reliability was R = .75 for girls and R = .80 for boys for teacher-reported CU and R = .69 and R = .70 for child-reported CU for girls and boys, respectively. CR reliability was examined using P, proportion of students who consistently passed or failed the test across 2 days, and km, defined as reliability with chance removed. For teacher-reported scores, P = .89 and km = .78 for boys and P = .81 and km = .62 for girls. For child-reported scores, P = .86 and km = .72 for boys, while P = .79 and km = .58 for girls. For teacher-reported data, 39% of boys passed and 50% failed the test on both days, while for girls the percentages were 27% pass and 54% fail. For child-reported data, 64% of boys passed and 22% failed on both days, while 54% of girls passed and 25% failed. NR validity was examined by correlating teacher and child-reported scores. The resultant coefficient was r = .42 (95% CI = .11-.66) for boys and r = .67 (95% CI = .58-.74) for girls. Additionally, child-reported scores were significantly higher than teacher-reported scores. CR validity was examined with a contingency coefficient, and results indicated C = .55 with 44% false master errors for boys and C = .65 with 29% false master errors for girls. The findings of this study suggest that while NR reliability estimates were moderate for teacher-reported scores, single trial estimates suggest that child-reported CU should be viewed with caution. In regard to CR reliability, both teacher-reported and child-reported reliability were moderate. However, there were marked differences between teacher- and child-reported scores, with children reporting higher percentages of students passing and lower percentage of student failing the test when compared with scores reported by teachers. Validity was rather moderate when viewed in either a NR and CR framework. It is suggested that problems with child-reported scores may be due to the need for additional practice or simplification of the testing protocol.  相似文献   

8.
A multitrait-multimethod (MTMM) matrix was used to evaluate validity evidence for a digital image manipulation (DIM) body image measurement technique in young women. One hundred one young women completed the DIM procedure and the Thompson and Gray (1995) Contour Drawing Rating Scale to measure self-ideal discrepancy and size perception accuracy components of body image. Seven-day test-retest reliability was acceptable (R = .81-.95). Convergent validity for self-ideal discrepancy was higher (r = .74) than the corresponding heterotrait, monomethod coefficients (r = .46, r = .23) and heterotrait-heteromethod coefficients (r = .18, r = .12). However, the convergent validity coefficient for size perception accuracy was r = .12. The pattern of correlations in the MTMM matrix met the criteria of Campbell and Fiske (1959) for validity of these procedures to measure self-ideal discrepancy but not size perception accuracy. The DIM procedure addresses some of the criticisms associated with figure-rating scales, such as unrepresentativeness of the figures, scale coarseness, and restriction of range in responses. DIM, therefore, represents a realistic, valid alternative to figure-rating scales for measuring self-ideal discrepancy.  相似文献   

9.
Abstract

A multitrait-multimethod (MTMM) matrix was used to evaluate validity evidence for a digital image manipulation (DIM) body image measurement technique in young women. One hundred one young women completed the DIM procedure and the Thompson and Gray (1995) Contour Drawing Rating Scale to measure self-ideal discrepancy and size perception accuracy components of body image. Seven-day test-retest reliability was acceptable (R = .81 ? .95). Convergent validity for self-ideal discrepancy was higher (r = .74) than the corresponding heterotrait, monomethod coefficients (r = .46, r = .23) and heterotrait-heteromethod coefficients (r = .18, r = .12). However, the convergent validity coefficient for size perception accuracy was r = .12. The pattern of correlations in the MTMM matrix met the criteria of Campbell and Fiske (1959) for validity of these procedures to measure selfideal discrepancy but not size perception accuracy. The DIM procedure addresses some of the criticisms associated with figurerating scales, such as unrepresentativeness of the figures, scale coarseness, and restriction of range in responses. DIM, therefore, represents a realistic, valid alternative to figure-rating scales for measuring self-ideal discrepancy.  相似文献   

10.
The purpose of this study was to investigate the test-retest reliability and concurrent validity of the Flemish Physical Activity Computerized Questionnaire (FPACQ) in employed/unemployed and retired people. The FPACQ was developed to assess detailed information on several dimensions of physical activity and sedentary behavior over a usual week. A triaxial accelerometer, the RT3 Triaxial Research Tracker (RT3), in combination with a written 7-day activity record, was used as the objective criterion measure. In employed/unemployed people, 2-week test-retest reliability for several activity variables calculated from the FPACQ was good to excellent with intraclass correlations (ICCs) ranging from .67 to .99. In retired people ICCs were lower but, except for time spent eating, still fair to excellent, ranging from .57 to .96. Except for time spent in leisure time activities for men and the average energy expenditure related to sports participation in women, correlations between the RT3 and the FPACQ generally supported the relative validity of the FPACQ for employed/unemployed people (r ranging from .37 to .88). Values for retired people were somewhat lower (r ranging from .15 to .85), but most variables still reached at least moderate correlations. Concerning absolute validity, the FPACQ generally overestimated physical activity and underestimated sedentary behavior compared to the RT3. From this study, it can be concluded that the FPACQ is a reliable and reasonably valid questionnaire for assessing different dimensions of physical activity and sedentary behavior.  相似文献   

11.
The purpose of this study was to investigate the test-retest reliability and concurrent validity of the Flemish Physical Activity Computerized Questionnaire (FPACQ) in employed/unemployed and retired people. The FPACQ was developed to assess detailed information on several dimensions of physical activity and sedentary behavior over a usual week. A triaxial accelerometer, the RT3 Triaxial Research Tracker (RT3), in combination with a written 7-day activity record, was used as the objective criterion measure. In employed/unemployed people, 2-week test-retest reliability for several activity variables calculated from the FPACQ was good to excellent with intraclass correlations (ICCs) ranging from .67 to .99. In retired people ICCs were lower but, except for time spent eating, still fair to excellent, ranging from .57 to .96. Except for time spent in leisure time activities for men and the average energy expenditure related to sports participation in women, correlations between the RT3 and the FPACQ generally supported the relative validity of the FPACQ for employed/unemployed people (r ranging from .37 to .88). Values for retired people were somewhat lower (r ranging from .15 to .85), but most variables still reached at least moderate correlations. Concerning absolute validity, the FPACQ generally overestimated physical activity and underestimated sedentary behavior compared to the RT3. From this study, it can be concluded that the FPACQ is a reliable and reasonably valid questionnaire for assessing different dimensions of physical activity and sedentary behavior.  相似文献   

12.
The purpose of the study was to develop a valid and reliable tool for use in assessing motor skills in preschool children in field based settings. The development of the CHAMPS (Children's Activity and Movement in Preschool Study) Motor Skills Protocol (CMSP) included evidence of its reliability and validity for use in field-based environments as part of large epidemiological studies. Following pilot work, 297 children (3-5 years old) from 22 preschools were tested using the final version of the CMSP and the TGMD-2. Reliability of the CMSP and interobserver reliability were determined using intraclass correlation procedures (ICC; ANOVA). Concurrent validity was assessed using Pearson correlation coefficients to compare the CMSP to the original Test of Gross Motor Development (2(nd) Edition) (TGMD-2). Results indicated that test reliability, interobserver reliability and validity coefficients were all high, generally above R/r = 0.90. Significant age differences were found. Outcomes indicate that the CMSP is an appropriate tool for assessing motor development of 3-, 4-, and 5-year-old children in field-based settings that are consistent with large-scale trials.  相似文献   

13.
The purpose of this study was to examine the validity and reliability of the Cooper 12-min swim test in high school male swimmers ages 13 to 17. Thirty-three boys performed three 12-min swims and 1 maximal graded treadmill test within a 14-day period. One practice swim was conducted 1 week prior to participation in this study. VO2max was assessed by indirect calorimetry with open-circuit spirometry with the Truemax 2400 metabolic cart (Consentius Technologies, Sandy, UT). Test-retest reliability of the 12-min swim assessed via 1-way analysis of variance indicated moderate reliability (R = .66, 95% confidence interval [CI] = .42-.81), whereas concurrent validity assessed via a Pearson product-moment correlation indicated a moderate relation (r = .47, 95% CI = .15-.70, r2 = .22). Results indicate that the Cooper 12-min swimming test is only moderately reliable after 2 practice swims and does not appear to be a valid field test of aerobic capacity in high school male swimmers ages 13 to 17.  相似文献   

14.
Abstract

Measuring lower body strength is critical in evaluating the functional performance of older adults. The purpose of this study was to assess the test-retest reliability and the criterion-related and construct validity of a 30-s chair stand as a measure of lower body strength in adults over the age of 60 years. Seventy-six community-dwelling older adults (M age = 70.5 years) volunteered to participate in the study, which involved performing two 30-s chair-stand tests and two maximum leg-press tests, each conducted on separate days 2–5 days apart. Test-retest intraclass correlations of .84 for men and .92 for women, utilizing one-way analysis of variance procedures appropriate for a single trial, together with a nonsignificant change in scores from Day 1 testing to Day 2, indicate that the 30-s chair stand has good stability reliability. A moderately high correlation between chair-stand performance and maximum weight-adjusted leg-press performance for both men and women (r = .78 and .71, respectively) supports the criterion-related validity of the chair stand as a measure of lower body strength. Construct (or discriminant) validity of the chair stand was demonstrated by the test's ability to detect differences between various age and physical activity level groups. As expected, chair-stand performance decreased significantly across age groups in decades–from the 60s to the 70s to the 80s (p < .01) and was significantly lower for low-active participants than for high-active participants (p < .0001). It was concluded that the 30-s chair stand provides a reasonably reliable and valid indicator of lower body strength in generally active, community-dwelling older adults.  相似文献   

15.
The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players' classification and competition standard, and rating of coach and player. Six field tests' test-retest showed good reliability (Intraclass correlation coefficient (ICC) = 0.80-0.97), while the pass-for-accuracy, free throws, lay-up and spot shot showed weak to moderate reliability (ICC = 0.26-0.67). Most tests showed moderate to good validity (r > 0.60). The results suggest that wheelchair basketball field tests are reliable and valid with the exception of the shooting and passing items, which should be interpreted carefully.  相似文献   

16.
This study sought to develop a modified submaximal cycle ergometer test designed to predict maximal oxygen consumption (VO2max) obtained on a treadmill. Volunteers (N = 156; women = 80, men = 76) with ages from 18 to 39 years old successfully performed a submaximal cycle protocol on a stationary cycle ergometer and a maximal graded exercise test (GXT) on a treadmill. Open circuit calorimetry was used during the GXT to measure VO2max. Multiple linear regression resulted in the following prediction equation: VO2max = 85.447 + 9.104 χSex (0 = women; 1 = men) - 0.2676 χAge (year) - 0.4150 χBody Mass (kg) + 0.1317 χPower Output (W) - 0.1615 χHeart Rate (bpm), which had acceptable validity (r = .88, standard error of estimate [SEE] = 3.12 ml· kg-1 · min-1). Selected participants (n = 34) performed the submaximal cycle ergometer test twice (within a 5-day period), yielding a test-retest intraclass reliability coefficient of r = .95 for VO2max estimations across days. The reliability of VO2max estimates for women (r = .93) was greater than that for men (r = .74). Cross-validation results were also acceptable using predicted residual sum of squares (PRESS; rPRESS = .87, SEEPRESS = 3.24 ml · kg-1 min-1), which suggests that the new equation should yield acceptable accuracy when it is applied to a similar, but independent sample of adults. In summary, the modified cycle ergometer test developed in this study yields relatively accurate estimates of treadmill VO2max in young adults, requires only a moderate level of exertion, and appears to be a convenient and time-efficient means of estimating cardiorespiratory fitness.  相似文献   

17.
目的旨在研究学龄儿童基本动作技能测试工具AST在国内使用的理论基础与可行性,通过测试技术操作和数据分析实证该测量工具的可信度、有效性与经济性。方法通过实验测试、数理统计等方法验证AST和KTK测量工具的信效度,通过转换后的大肌肉动作协调能力商数(KTKMQ)校标基本动作技能AST测试的同时效度和区别效度。结果受试儿童年龄为7~12岁,平均在(44±11) s的时间完成了AST-1全程测试,在(45±12) s的时间完成了AST-2全程测试;AST-1测试成绩与KTKMQ的相关系数r=0.474(P<0.01),而AST-2测试成绩与KTKMQ呈现中度相关系数r=0.502(P<0.01);除7岁年龄组的AST-2测试与KTKMQ相关性较低外,其他年龄组的相关性均较高(r=0.469和r=0.767)。结论小学学段的体育教学环境中AST测试工具可以快速、便捷、有效的评估儿童的基本动作技能;运动技能轨道AST测量工具在本次研究中表现出较强的测试适宜性,具有重测信度;各年龄组测量结果的区分度和测试项目的鉴别力验证了测量工具的同时效度和区别效度。  相似文献   

18.
This study aimed to introduce a technique using computer-assisted image analysis for measuring body segmental angles during a static strength element on parallel bars. Criterion validity and intra-rater reliability of measurements were evaluated using digital photography, skin markers and a gravity-reference goniometer. Twenty male former gymnasts participated in this study. They performed a strength hold element on parallel bars (V-sit) and they were photographed with legs extended and stabilized at the highest possible level. The leg to horizontal, trunk to vertical and arm to vertical angles were calculated and examined for reliability using image-pro software. The leg angle was also examined for its validity, by simultaneously using a Myrin goniometer. The two goniometric techniques indicated high leg angle measurements agreement (R = 0.997, p < 0.001). However, Bland-Altman analysis showed that there was a slight leg angle measurement overrating using image-pro software, especially at smaller angles. The Intra-class Correlation Coefficient (ICC) values were high for leg angle (R = 0.971), trunk angle (R = 0.957) and arm angle (R = 0.945), showing an excellent test-retest agreement. It was ascertained that the measurement of segmental angles during V-sit on parallel bars using digital photography and computer-assisted image analysis can be highly reliable when taken by the same experienced examiner.  相似文献   

19.
Abstract

The purpose of the present investigation was to determine the relationships of the sit and reach test, a component of the American Alliance for Health, Physical Education, Recreation and Dance Health Related Fitness Test, 1980, with criterion measures of back and hamstring flexibility. Young females (N = 100) with a mean age of 14.08 years ± .825 were administered two trials of three tests. The measurements included the sit and reach test, passive hamstring flexibility using a Leighton Flexometer, and a test of back flexibility using a protocol suggested by Macrae and Wright in 1969. Test-retest reliability estimates exceeded .90 for all measurements. Results indicated that the sit and reach test had a moderate relationship (r = .64) with passive hamstring flexibility. The correlations between the sit and reach test and total back flexibility (r = .07), upper back flexibility (r = ?.16), and lower back flexibility (r = .28) were low. These findings indicate the sit and reach test has moderate criterion-related validity when used as an assessment of hamstring flexibility, but appears not to provide a valid assessment of back and, in particular, low back flexibility which is one of the reasons it was included in the Health Related Fitness Test.  相似文献   

20.
ABSTRACT

The aims of this study were to perform the cross-cultural adaptation of the Borg Rating of Perceived Exertion (RPE) 6–20 Scale to Brazilian Portuguese language and to start testing its validity and reliability. After performing the cross-cultural adaptation of the Scale, concurrent and discriminative validity, and reliability were determined on a treadmill in young (18–30 years) and older adult women (60–75 years). Considering young and older adult women, RPE presented high and moderate positive correlation with heart rate and high and low positive correlation with oxygen consumption, respectively. Older adult women presented RPE (11 ± 2) significantly higher than young ones (8 ± 1) exercising at the same absolute intensity. Intraclass coefficient correlation was excellent for RPE to young and older adult women. The Scale presented concurrent validity only to young adult women, whereas it presented discriminative validity between such groups of women. Moreover, the scale is reliable to young and older adult women.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号