首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
IntroductionIndirect estimation of reference intervals (RIs) is straightforward and inexpensive procedure for determination of intra-laboratory RIs. We applied the indirect approach to assess RIs for haematological parameters in capillary blood of pre-school children, using results stored in our laboratory database.Materials and methodsWe extracted data from laboratory information system, for the results obtained by automatic haematology analyser in capillary blood of 154 boys and 146 girls during pre-school medical examination. Data distribution was tested, and logarithmic transformation was applied if needed. Reference intervals were calculated by the nonparametric percentile method.ResultsReference intervals were calculated for: RBC count (4.2-5.4 x1012/L), haemoglobin (114-146 g/L), MCH (25.0-29.4 pg), MCHC (321-368 g/L), RDW-SD (36.1-43.5 fL), WBC count (4.5-12.3 x109/L), neutrophils count (1.7-6.9 x109/L) and percentage (29.0-69.0%), lymphocytes count (1.6-4.4 x109/L) and percentage (21.9-60.7%), PLT (165-459 x109/L), MPV (8.1-11.4 fL) and PDW (9.2-14.4%). Gender specific RIs were calculated for monocytes count (male (M): 0.2-1.6 x109/L; female (F): 0.1-1.4 x109/L) and percentage (M: 2.5-18.3%; F: 1.8-16.7%), haematocrit (M: 0.34-0.42 L/L; F: 0.34-0.43 L/L), MCV (M: 73.4-84.6 fL; F: 75.5-84.2 fL) and RDW (M: 12.1-14.3%; F: 11.7-13.9%), due to observed gender differences in these parameters (P = 0.031, 0.028, 0.020, 0.012 and 0.001; respectively). Estimated RIs markedly varied from the literature based RIs that are used in the laboratory.ConclusionsIndirect method employed in this study enables straightforward assessment of RIs in pre-school children. Herein derived RIs differed from the literature-based ones, indicating the need for intra-laboratory determination of RIs for specific populations and sample types.  相似文献   

2.
IntroductionEvaluation of thyroid function is often requested and therefore defining paediatric reference intervals (RIs) is of vital importance. Currently, there is a distinct lack of paediatric RIs for thyroid function tests in Croatia. Thus, we established RIs for thyroid stimulating hormone (TSH), total triiodothyronine (TT3), total thyroxine (TT4), free triiodothyronine (FT3) and free thyroxine (FT4) in the Croatian paediatric population.Materials and methodsReference intervals were calculated from 397 apparently healthy children, aged from 2 days to < 19 years. Serum samples were analysed for thyroid function tests on the Abbott Architect i2000. Age- and sex-specific 95% RIs with 90% confidence intervals were established according to Clinical and Laboratory Standards Institute guidelines. To express the magnitude of sex and age variation, standard deviation ratio (SDR) was calculated using two-level nested ANOVA. The criterion for considering partitioning reference values was set to SDR > 0.3.ResultsAll thyroid function tests required age partitioning, confirmed by SDR above 0.3. There was no need for sex partitioning, confirmed by SDR below 0.3. Still, FT3 was partitioned due to visually noticeable sex related difference for the oldest group (12 years to < 19 years).ConclusionThis is the first study to establish RIs for thyroid function tests in the Croatian paediatric population. We propose RIs for widely used Abbott platform, thus giving laboratories method- and population-specific paediatric RIs for thyroid function tests that should improve clinical test interpretation.  相似文献   

3.
The reference intervals (RIs) of serum aminotransferases and Gamma-glutamyl transferase (GGT) have been established many years ago. Recent RIs are not available. The prospective study was conducted to re-evaluate the RIs of liver enzymes and the effect of demographic and anthropometric variables on them in western Indian population. A total of 1059 blood donors comprised the study population. Anthropometry and serum liver enzymes levels were measured. Subjects were categorized into normal weight and overweight by using body mass index (BMI) and waist circumference (WC). For RI determination, non-parametric methodology recommended by IFCC/CLSI was adopted. Mann–Whitney test and Spearman’s rank correlation were used for statistical analysis. Upper limit of normal reference value of liver enzymes were lower in female compared to male. (ALT—23.55 F vs 36.00 M, GGT—34.58 F vs 36.20 M) When RI of liver enzymes were calculated according to body mass index, the upper limit of normal of ALT and GGT were higher in overweight group compared to normal weight group. (ALT—38.00 vs 27.00 IU/L and GGT—37.59 vs 35.26 IU/L). In both male and female, liver enzymes correlated significantly with age. WC and BMI were positively correlated with AST, ALT and GGT in both subgroups and the correlation was stronger in male. Demographic factors should be considered for making liver enzyme tests more clinically relevant. Gender based partitioning should be adopted for serum alanine aminotransferase (ALT) and GGT reference values for Western Indian population.  相似文献   

4.
Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term ‘RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area.
The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs.Key words: multicenter study, common reference intervals, reference values, clinical decision limits, genetic information  相似文献   

5.

Introduction

Postmenopausal women have higher risk of cardiovascular disease. One of the contributing factors could be reduced activity of anti-atherogenic enzyme paraoxonase 1 (PON1). The aim of this study was to examine differences in the lipid status, paraoxonase and arylesterase PON1 activities and PON1 phenotype in women with regular menstrual cycle and in postmenopausal women.

Materials and methods:

The study included 51 women in reproductive age (25 in follicular and 26 in luteal phase of the menstrual cycle) and 23 women in postmenopause. Lipid parameters in sera were determined using original reagents and according to manufacturer protocol. PON1 activity in serum was assessed by spectrophotometric method with substrates: paraoxon and phenylacetate. PON1 phenotype was determined by double substrate method.

Results:

Compared to the women in follicular and luteal phase, postmenopausal women have significantly higher concentration of triglyceride [0.9 (0.7–1.3), 0.7 (0.6–1.0) vs. 1.5 (0.9–1.7) mmol/L; P = 0.002], cholesterol [5.10 (4.78–6.10), 5.05 (4.70–5.40) vs. 6.30 (5.73–7.23) mmol/L; P < 0.001], LDL [3.00 (2.56–3.63), 3.00 (2.70–3.70) vs. 3.90 (3.23–4.50) mmol/L; P < 0.001], and apolipoprotein B [0.88 (0.75–1.00), 0.79 (0.68–1.00) vs. 1.07 (0.90–1.24) mmol/L; P = 0.002]. PON1 basal [104 (66–260), 106 (63–250) vs. 93 (71–165) U/L; P = 0.847] and salt-stimulated paraoxonase activity [210 (131–462), 211 (120–442) vs. 180 (139–296) U/L; P = 0.857] as well as arylesterase activity [74 (63–82), 70 (54–91) vs. 70 (60–81) kU/L; P = 0.906] and PON1 phenotype (P = 0.810) were not different in the study groups.

Conclusion:

There are no differences in PON1 activity and PON1 phenotype between women with regular menstrual cycle and postmenopausal women.  相似文献   

6.

Introduction

Although prostatitis is a common male urinary tract infection, clinical diagnosis of prostatitis is difficult. The developmental mechanism of prostatitis is not yet unraveled which led to the elaboration of various biomarkers. As changes in asparagine-linked-(N-)-glycosylation were observed between healthy volunteers (HV), patients with benign prostate hyperplasia and prostate cancer patients, a difference could exist in biochemical parameters and urinary N-glycosylation between HV and prostatitis patients. We therefore investigated if prostatic protein glycosylation could improve the diagnosis of prostatitis.

Materials and methods

Differences in serum and urine biochemical markers and in total urine N-glycosylation profile of prostatic proteins were determined between HV (N = 66) and prostatitis patients (N = 36). Additionally, diagnostic accuracy of significant biochemical markers and changes in N-glycosylation was assessed.

Results

Urinary white blood cell (WBC) count enabled discrimination of HV from prostatitis patients (P < 0.001). Urinary bacteria count allowed for discriminating prostatitis patients from HV (P < 0.001). Total amount of biantennary structures (urinary 2A/MA marker) was significantly lower in prostatitis patients compared to HV (P < 0.001). Combining the urinary 2A/MA marker and urinary WBC count resulted in an AUC of 0.79, 95% confidence interval (CI) = (0.70–0.89) which was significantly better than urinary WBC count (AUC = 0.70, 95% CI = [0.59–0.82], P = 0.042) as isolated test.

Conclusions

We have demonstrated the diagnostic value of urinary N-glycosylation profiling, which shows great potential as biomarker for prostatitis. Further research is required to unravel the developmental course of prostatic inflammation.Key words: diagnostic marker, prostatitis, urinary asparagine-linked glycosylation  相似文献   

7.
IntroductionTotal bilirubin tests are highly demanded in clinical laboratories. Since icteric index (I-index) has zero cost, we aimed to evaluate its clinical utility and cost-effectiveness to determine if total bilirubin is necessary to be tested. We took into account if haemolysis could interfere to icteric index determination.Material and methodsRetrospectively we reviewed I-index results in two cohorts (43,372 and 8507 non-haemolysed and haemolysed samples, respectively). All determinations were done using Alinity c chemistry analysers (Abbott Diagnostics). Receiver operating characteristic (ROC) curve was used to determine the optimal index cut-off to discriminate between normal and abnormal bilirubin concentration (20.5 µmol/L).ResultsThe ROC curve analysis suggested 21.4 µmol/L as the optimal I-index cut-off but differences in sensitivity and specificity were detected between patient derivation. For rejecting purpose, 15.4 µmol/L and 17.1 µmol/L I-index thresholds were selected based on patient derivation (inpatients and emergency room; and primary care and outpatients, respectively) with 97% sensitivity and 0.25% false negative results. Sensitivity was much lower in haemolysed samples. We selected 34.2 µmol/L I-index as threshold to detect hyperbilirubinemia with 99.7% specificity and 0.26% false positive results, independent of haemolysis. With the icteric index cut-offs proposed, we would save 66% of total bilirubin requested and analyse total bilirubin in around 2% of samples without total bilirubin requested.ConclusionsThis study supports the use of I-index to avoid bilirubin determination and to identify patients with hyperbilirubinemia. This work considers that the economic and test savings could help to increase the efficiency in clinical laboratories.  相似文献   

8.
IntroductionMost laboratories routinely determine haemolysis, icterus and lipemia indices to identify lipemic samples and reject potentially affected results. Hypertriglyceridemia is the most common cause of lipemia and severe hypertriglyceridemia (≥ 11.3 mmol/L) is a major risk factor of acute pancreatitis.Laboratory analysisA 56-year-old woman attended the outpatient clinic for a follow-up visit 1 month after a kidney transplantation. Her immunosuppressive therapy consisted of corticosteroids, cyclosporine, and mycophenolic acid. The routine clinical chemistry sample was rejected due to extreme lipemia. The comment “extreme lipemic sample” was added on the report, but the requesting physician could not be reached. The Cobas 8000 gave a technical error (absorption > 3.3) for the HIL-indices (L-index: 38.6 mmol/L) which persisted after high-speed centrifugation. The patient was given a new appointment 2 days later. The new sample was also grossly lipemic and gave the same technical error (L-index: 35.9 mmol/L).What happenedThe second sample was manually diluted 20-fold after centrifugation to obtain a result for triglycerides within the measuring range (0.10–50.0 mmol/L). Triglycerides were 169.1 mmol/L, corresponding to very severe hypertriglyceridemia. This result was communicated to the nephrologist and the patient immediately recalled to the hospital. She received therapeutic plasma exchange the next day and did not develop acute pancreatitis.Main lessonThis case illustrates the delicate balance between avoiding the release of unreliable results due to lipemia and the risk of delayed diagnosis when results are rejected. Providing an estimate of the degree of hypertriglyceridemia might be preferable to rejecting the result.  相似文献   

9.
Ovarian cancer has been emerged as a most common and lethal gynecological malignancy in India. High serum insulin and low adiponectin have been associated with increased risk of ovarian cancer. But their role in development of ovarian cancer is conflicting and little evidence is available. We aimed to evaluate blood levels of insulin and adiponectin in epithelial ovarian cancer (EOC) patients and their association with the risk to develop EOC. The study included following three groups; Group 1: fifty cases of cytohistopathologically confirmed cases of EOC, Group 2: fifty age matched cases of benign ovarian conditions and Group 3: fifty ages matched healthy controls with no evidence of any benign or malignant ovarian pathology as ruled out by clinical examination and relevant investigations. Cytohistopathologically confirmed and newly diagnosed cases of EOC and benign ovarian cancer were included in this study. The median value of fasting serum insulin was significantly high (15.0 µlU/ml, P = 0.02) and adiponectin were significantly low (5.1 µg/ml, P < 0.001) in ovarian cancer patients compared to benign ovarian tumors and healthy controls group. A significant increase risk of ovarian cancer was found in high tertile (≥ 18.7 µlU/ml) of serum insulin level (OR = 2.7; 95% CI = 1.00–6.67, P = 0.04) and lower tertile (≤ 5.45 µg/ml) of adiponectin level (OR = 3.2; 95% CI = 1.10–9.71, P = 0.03). High serum insulin level and low adiponectin levels were significantly associated with increased risk for development of ovarian cancer.  相似文献   

10.
Recent studies have shown that there are systematic differences among total and free prostate-specificantigen (PSA) immunoassays. In this study we analyzedintermethod differences in total PSA (tPSA) and free PSA(fPSA) measurement using ARCHITECT i2000SR (Abbott Diagnostics) and COBAS E601 (Roche Diagnostics). A number of 160 blood samples were tested for tPSA and 50 samples for fPSA (selecting only sampleswith tPSA: 4.1–10.0 μg/L). Passing–Bablok regression analysis was used to compare the two analytical methods fortPSA, fPSA and percentage of fPSA (%fPSA). A strong correlation was noticed between ARCHITECT i2000SR and COBAS E601 for tPSA, fPSA and %fPSA (r between 0.94 and 0.99). Concentrations of tPSA and fPSA measured by COBAS E601 were higher thanthose measured by ARCHITECT i2000SR with a bias of 0.8 μg/L for tPSA and 0.14 μg/L for fPSA. Analyzing therelative difference between methods for fPSA and %fPSA, COBAS E601 exceed a 10% relative difference limit. Our study confirms that there are differences in measured concentrations of tPSA and fPSA byvarious commercial methods. Because clinical judgment on subsequent diagnostic procedures, such as prostatebiopsy, is based on tPSA and fPSA results, tests harmonization should be a priority.  相似文献   

11.
IntroductionIt is common for patients to switch between several healthcare providers. In this context, the long-term follow-up of medical conditions based on laboratory test results obtained from different laboratories is a challenge. The measurement uncertainty in an inter-laboratory context should also be considered in data mining research based on routine results from randomly selected laboratories. As a proof-of-concept study, we aimed at estimating the inter-laboratory reference change value (IL-RCV) for exemplary analytes from publicly available data on external quality assessment (EQA) and biological variation.Materials and methodsExternal quality assessment data of the Reference Institute for Bioanalytics (RfB, Bonn, Germany) for serum creatinine, calcium, aldosterone, PSA, and of whole blood HbA1c from campaigns sent out in 2019 were analysed. The median CVs of all EQA participants were calculated based on 8 samples from 4 EQA campaigns per analyte. Using intra-individual biological variation data from the EFLM database, positive and negative IL-RCV were estimated with a formula based on log transformation under the assumption that the analytes under examination have a skewed distribution.ResultsWe estimated IL-RCVs for all exemplary analytes, ranging from 13.3% to 203% for the positive IL-RCV and - 11.8% to - 67.0% for the negative IL-RCV (serum calcium - serum aldosterone), respectively.ConclusionExternal quality assessment data together with data on the biological variation – both freely available – allow the estimation of inter-laboratory RCVs. These differ substantially between different analytes and can help to assess the boundaries of interoperability in laboratory medicine.  相似文献   

12.

Background

The preanalytical phase represents the major source of variability in laboratory diagnostics. Our aim was to assess to what extent underfilling of primary blood tubes may impact upon routine coagulation testing.

Materials and methods:

Blood was drawn by syringe from 21 healthy volunteers and 6 patients on warfarin therapy, and immediately transferred into 3.6 mL vacuum tubes containing 3.2% sodium citrate (Terumo Europe N.V., Leuven, Belgium). All tubes were filled using standardized volumes of whole blood to produce scalar amounts of filling: 3.6 mL (i.e., 100%), 3.2 mL (89%), 2.8 mL (78%) and 2.4 mL (67%). Samples were mixed and centrifuged at 1300 × g for 10 min. The plasma was tested for prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FBG) on ACL TOP (Instrumentation Laboratory - IL, Milan, Italy), using IL reagents. A polynomial plot was derived for each parameter from interpolation of clotting values obtained with different percentages of filling, and these plots were compared with quality specifications (± 2.0 for PT, ± 2.3 for APTT and ± 4.8 for FBG) to calculate the minimal filling volume required to produce clinically acceptable results.

Results:

The equations were (PF, Percentage of filling): PT (sec) = 3.375 × PF^2–6.255 × PF + 17.806 (r = 0.980); APTT (sec) = 8.925 × PF^2–23.578 × PF + 46.356 (r = 0.979); and FBG (mg/dL) = −311.5 × PF^2 + 422.1 × PF + 147.07 (r = 0.994). According to these equations, the minimum allowed thresholds of blood tubes filling were > 61% for PT, > 87% for APTT and > 71% for FBG.

Conclusions:

Our results confirm that routine coagulation testing performed on underfilled tubes may generate biased and clinically misleading test results. This is particularly critical for APTT, wherein tubes filled at less than ∼90% generate unreliable data. The FBG and the PT seem more resistant to underfilling, clinical significant biases being observed only where blood tubes were filled at less than ∼60 and ∼70%, respectively.  相似文献   

13.

Introduction

Sparse data are available about the effect of therapy methods on antibody levels in patients with liver failure. The aim of this study was to determine serum immunoglobulin concentrations in patients with chronic hepatic failure (CHF), acute- (ALF), or acute-on-chronic liver failure (ACLF) and to evaluate the impact of MARS treatment or liver transplantation (LT) on antibody levels.

Materials and methods

We followed ten patients with ALF, twelve with ACLF and 18 with CHF. Eight patients with ALF and seven with ACLF underwent MARS therapy, whereas the rest received LT. 13 healthy volunteers served as controls. Serum antibody concentrations were measured using ELISA-technique.

Results

Median serum levels of IgA, IgG and IgM were significantly increased in patients with CHF compared to ALF or controls (P < 0.02, P < 0.01, and P < 0.01). IgM and IgG concentrations were also significantly elevated in patients with CHF compared to ACLF (IgM, 3.7 vs. 1 g/L, P < 0.001; IgG, 8.7 vs. 3.1 g/L, P = 0.004). Immediately after LT a significant decrease of IgA (6.9 vs. 3.1 g/L, P = 0.004), IgG (8.7 vs. 5.1 g/L, P = 0.02) and IgM (3.7 vs. 1.8 g/L, P = 0.001) was detected in patients with CHF and antibody levels further decreased the days after LT reaching levels comparable to healthy individuals. MARS treatment had no apparent effect on the immunoglobulin profile in patients with ALF or ACLF.

Conclusion

We provide evidence that LT reverses hypergammaglobulinemia in patients suffering from CHF within one day, which could be explained to a reconstituted hepatic antibody clearance, whereas MARS treatment has no immediate effect on immunoglobulin levels.Key words: antibodies, immunoglobulins, liver failure, liver transplantation, artificial liver support system, molecular adsorbent recirculating system  相似文献   

14.
As a non-invasive therapeutic method without penetration-depth limitation, magnetic hyperthermia therapy (MHT) under alternating magnetic field (AMF) is a clinically promising thermal therapy. However, the poor heating conversion efficiency and lack of stimulus–response obstruct the clinical application of magnetofluid-mediated MHT. Here, we develop a ferrimagnetic polyethylene glycol-poly(2-hexoxy-2-oxo-1,3,2-dioxaphospholane) (mPEG-b-PHEP) copolymer micelle loaded with hydrophobic iron oxide nanocubes and emodin (denoted as EMM). Besides an enhanced magnetic resonance (MR) contrast ability (r2 = 271 mM−1 s−1) due to the high magnetization, the specific absorption rate (2518 W/g at 35 kA/m) and intrinsic loss power (6.5 nHm2/kg) of EMM are dozens of times higher than the clinically available iron oxide nanoagents (Feridex and Resovist), indicating the high heating conversion efficiency. Furthermore, this composite micelle with a flowable core exhibits a rapid response to magnetic hyperthermia, leading to an AMF-activated supersensitive drug release. With the high magnetic response, thermal sensitivity and magnetic targeting, this supersensitive ferrimagnetic nanocomposite realizes an above 70% tumor cell killing effect at an extremely low dosage (10 μg Fe/mL), and the tumors on mice are completely eliminated after the combined MHT–chemotherapy.  相似文献   

15.

Introduction:

Serum blood collection tubes with separator gel are widely used by many laboratories for chemistry analyses. We describe a case of a primary blood collection tube filled with blood sample and a floating separator gel.

Materials and methods:

The blood sample was collected from a 51 years old female in intensive care unit with the diagnosis of pneumonia into a BD Vacutainer SST tube (Becton Dickinson, NJ, USA) containing serum separator gel and conveyed to the core laboratory of Marmara University Hospital within 30 minutes from collection. Sample was immediately centrifuged at room temperature at 1500 × g for 10 minutes.

Results:

The analyses revealed a highly increased total protein concentration of 145 g/L (reference interval 64–83 g/L). The nephelometric analyses showed an elevated serum IgG concentration of 108 g/L (reference interval 6.5–16 g/L) and IgG lambda monoclonal band was determined by serum immunofixation electrophoresis.

Conclusion:

Limitation of the separator gel tubes in patients with a high plasma density and its possible effects on test results and laboratory costs should be remembered. The clinical diagnosis stated in the information system should also reveal known comorbid conditions besides the apparent admission reason. This information would avoid resampling, additional testing, and communication efforts with the clinicians.  相似文献   

16.
Reference intervals (RIs) of serum thyroid stimulating hormone (TSH) and free thyroxine (fT4) were determined in 402 healthy pregnant women by enzyme-linked immunosorbent assay (ELISA) technique after partitioning them into three trimesters. The reference population was chosen from a study population of 610 pregnant females by applying strict inclusion and exclusion criteria. The assays were done using proper quality control measures. RIs were calculated from the central 95 % of the distribution of TSH and fT4 values located between the lower reference limit of 2.5 percentile and upper reference limit of 97.5 percentile value 0.90 confidence intervals for the upper and lower reference limits were also determined. The reference intervals for TSH were 0.25–3.35 μIU/ml for the first trimester; 0.78–4.96 μIU/ml for the second trimester and 0.89–4.6 μIU/ml for the third trimester. Similarly, the reference intervals for fT4 for first, second and third trimesters were 0.64–2.0, 0.53–2.12 and 0.64–1.98 ng/dl respectively. The values thus obtained varied from those provided by the kit literature. In comparison to our derived reference intervals, the reference data from kit manufacturer under-diagnosed both subclinical hypo- and hyper-thyroidism within our pregnant reference population.  相似文献   

17.
Mucopolysaccharidoses, a group of inherited disorders are associated with defects in glycosaminoglycan metabolism. Thus, assessment of urinary glycosaminoglycan is used as a screening test for mucopolysaccharidoses. The detection methods range from qualitative spot tests to quantification using metachromatic dyes. In our laboratory we optimized a spectrophotometric quantitative method using a metachromatic dye, dimethylmethylene blue. Heparan sulfate was used for quantification. The glycosaminoglycan–dye complex showed a marked shift in color with increase in concentration. The color complex was quantified at 520 nm. The method was linear from 10–89 mg/L. An age matched normal range was obtained in 177 healthy individuals, grouped in 8 different age groups from neonates to adults. Urinary glycosaminoglycan concentration varied distinctly amongst the study population wherein the lowest range in healthy neonates was more than 3 times the upper limit of healthy adults. Urine samples from 10 patients with mucopolysaccharidoses were also included in the study for clinical validation. The method qualified both analytical and clinical validation and was found to be simple, robust and ideal to be offered as a screening test for mucopplysaccharidoses in a routine clinical chemistry laboratory.  相似文献   

18.
A metabolomic study for determination of certain urinary metabolomes, 1-methyladenosine (1-MA), 1-methylguanosine (1-MG), and 8-hydroxy-2′ deoxyguanosine (8-OHdG) in urine specimens of breast cancer patients. The accuracy of these metabolites and their combined score with cancer antigen 15-3 (CA15-3) was developed to improve the early detection of breast cancer. This study recruited 52 healthy individuals, 47 benign breast tumors, and 167 malignant breast tumor patients. Urine samples were handled to adjust the creatinine concentrations to 8 mg/dL (0.7 mmol/L) and analyzed using GC–MS to detect and quantify the selected urinary metabolomes in urine samples of all participants. The accuracy of individual urinary metabolomes and their combination with CA15-3 were evaluated using multivariate statistical analysis. The cutoff value of CA15-3 was 32.5 U/mL. Cutoff values of 1-MA, 1-MG, and 8-OHdG were 2.19, 2.1, and 7.3 µmol/mmol creatinine, respectively. The concentrations of 1-MA, 1-MG, and 8-OHdG were significantly higher in breast cancer patients, especially in the early-stage. The combination of three urinary metabolomes with CA15-3 improves the diagnostic sensitivity of breast cancer. For the combined score, the area under the curve (AUC) value of combined score ranged from 0.820 to 0.950, with high accuracy, ranged from 77.0 to 95.5%. The most significant AUC (0.973), sensitivity (90.1%), selectivity (94.0%) was recorded at comparing the healthy control with the early-stage of malignant breast cancer. In conclusion, the combination of three urinary metabolomes with serum CA15-3 improves the diagnostic sensitivity of breast cancer.  相似文献   

19.

Introduction:

Zonulin is a eukaryotic protein structurally similar to Vibrio cholerae’s zonula occludens toxin. It plays an important role in the opening of small intestine tight junctions. The loss of gut wall integrity during sepsis might be pivotal and has been described in various experimental as well as human studies. Increased levels of zonulin could be demonstrated in diseases associated with increased intestinal inflammation, such as celiac disease and type 1 diabetes. We therefore investigated the role of plasma levels of zonulin in patients with sepsis as a non-invasive marker of gut wall integrity.

Materials and methods:

Plasma level of zonulin was measured in 25 patients with sepsis, severe sepsis or septic shock according to ACCP/SCCM criteria at the first day of diagnosed sepsis. 18 non-septic post-surgical ICU-patients and 20 healthy volunteers served as control. Plasma levels were determined by using commercially available ELISA kit. Data are given as median and interquartile range (IQR).

Results:

Significantly higher plasma concentration of zonulin were found in the sepsis group: 6.61 ng/mL (IQR 3.51–9.46), as compared to the to the post-surgical control group: 3.40 ng/mL (IQR 2.14–5.70) (P = 0.025), as well as to the healthy group: 3.55 ng/mL (IQR 3.14–4.14) (P = 0.008).

Conclusion:

We were able demonstrate elevated levels of plasma zonulin, a potential marker of intestinal permeability in septic patients. Increased zonulin may serve as an additional mechanism for the observed increased intestinal permeability during sepsis and SIRS.  相似文献   

20.
IntroductionIt is often quoted that 70% of clinical decisions are based on laboratory results, but the evidence to substantiate this claim is lacking. Since clinical guidelines aim to document best-practice decision making for specific disease conditions, inclusion of any laboratory test means that the best available evidence is recommending clinicians use it. Cardiovascular disease (CVD) is the world’s most common cause of mortality, so this study reviewed all CVD guidelines published by five national/international authorities to determine what proportion of them recommended laboratory testing.Materials and methodsFive leading CVD guidelines were examined, namely the European Society of Cardiology (ESC), the UK National Institute for Health and Clinical Excellence (NICE), the American College of Cardiology (ACC), the Australian Heart Foundation (AHF) and the Cardiac Society of Australia and New Zealand (CSANZ).ResultsA total of 101 guidelines were reviewed. Of the 33 individual ESC guidelines relating to CVD, 24/33 made a direct reference to the use of clinical laboratory tests in either diagnosis or follow-up treatment. The same applied to 15/20 of NICE guidelines, 24/32 from the ACC and 15/16 from the AHF/CSANZ. Renal function and blood count testing were the most recommended (39 and 26 times), with lipid, troponin and natriuretic peptide measurement advocated 25, 19 and 19 times respectively.ConclusionsThis study has shown that laboratory testing is advocated by between 73% and 94% of individual CVD guideline recommendations from five national/international authorities. This provides an index to assess the potential value of laboratory medicine to healthcare.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号