首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
教育   1篇
科学研究   6篇
  2022年   1篇
  2021年   2篇
  2015年   2篇
  2012年   1篇
  2007年   1篇
排序方式: 共有7条查询结果,搜索用时 31 毫秒
1
1.

Introduction

Hemolysis can occur during sample collection, handling and transport. It is more frequent when the non-laboratory staff performs sampling. The aim of this study was to assess nurses’ knowledge on the causes of hemolysis and consequential impact on the laboratory tests results. Additionally, the differences in knowledge, related to work experience, professional degree and previous education about hemolysis were explored.

Materials and methods

An anonymus survey, containing 11 questions on demographics, causes of hemolysis, its impact on biochemical parameters and nurses’ attitude towards additional education in preanalytics, was conducted in four Croatian hospitals. The answers were compared by Chi-squared and Fischer exact test.

Results

In total, 562 survey results were collected. Majority of nurses declared familiarity with the term “hemolysis” (99.6%). There were 77% of correct answers regarding questions about the causes of hemolysis, but only 50% when it comes to questions about interference in biochemical tests. The percentage of correct answers about causes was significantly lower (P = 0.029) among more experienced nurses, and higher (P = 0.027) in those with higher professional degree, while influence of previous education was not significant. Also, higher percentage of correct answers about interferences was encountered in nurses with longer work experience (P = 0.039). More than 70% of nurses declared that additional education about preanalytical factors would be beneficial.

Conclusion

Croatian nurses are familiar with the definition of hemolysis, but a lack of knowledge about causes and influence on laboratory test results is evident. Nurses are eager to improve their knowledge in this field of preanalytical phase.Key words: hemolysis, nurses, survey, preanalytical phase  相似文献   
2.

Introduction

The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia.

Materials and methods:

Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%).

Results:

The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%.

Conclusion:

We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose.  相似文献   
3.
虚拟现实技术是21世纪的前沿技术,通过我校参加广州市教育科学“十五”规划课题《片剂车间虚拟现实教学系统的开发与研究》,就虚拟现实技术的特征及其在职业教育中的应用作进行了探索。  相似文献   
4.
IntroductionActivated partial thromboplastin time (aPTT) is determined and reported as clotting time in seconds aPTT(s), but it is presumed that reporting results as patient-to-normal clotting time ratio, aPTT(r), could minimize within-laboratory variability. The aim of study was to investigate differences in reporting aPTT results that can affect comparability of the results among Croatian laboratories and suggest further steps for its harmonization.Materials and methodsThe questionnaire on aPTT reporting practice was distributed to 83 laboratories through Survey Monkey application in March 2019 as the part of the first regular round of Croatian Centre for Quality Assessment in Laboratory Medicine proficiency testing.ResultsThe survey response rate was 0.49. Majority of laboratories report aPTT results as both, seconds and ratio. Participants reported use of 23 different aPTT(s) reference intervals along with 17 different combinations of reagent/coagulometer and 25 aPTT(s) denominators of different origin for aPTT(r) calculation. Despite the same aPTT(s) results, the use of different denominators caused a dispersion of aPTT(r) results that can lead to exceeding external quality assessment performance criteria of 7%, particularly when results were compared for the same reagent group only. By applying aPTT(s) reference interval mean as denominator for calculation of aPTT(r) reference interval better concordance to harmonized one was obtained (17 vs. 27; χ2 = 3.972; P = 0.046).ConclusionIn order to improve comparability of the results, laboratories are advised to use mean of aPTT(s) reference interval as denominator for aPTT(r) calculation. Type of coagulometer need to be considered when evaluating aPTT proficiency test results and its currently acceptable limit of performance evaluated accordingly.  相似文献   
5.
IntroductionIntensive physical activity causes functional and metabolic changes in the athlete’s organism. The study aimed to verify the common national available reference intervals (RIs) for common inflammatory and screening coagulation tests in a population of healthy young female athletes.Materials and methodsOne hundred and twenty-one female athletes (age range: 16–34), from various sports disciplines (water polo, handball, volleyball, football, basketball), were included in the study. All participants completed the international physical activity short-form questionnaire. Blood samples were collected between 8–10 am, after an overnight fast, before any physical activity. Reference intervals were determined according to Clinical & Laboratory Standards Institute EP28-A3C Guidelines.ResultsCalculated RIs for white blood cell count (WBC), prothrombin time (PT), and activated partial thromboplastin time (APTT) ratio were in accordance with the common national RIs. Calculated RI for C-reactive protein (CRP) was lower (< 2.9 mg/L) than the proposed cut-off for a healthy population (< 5.0 mg/L). Reference interval for fibrinogen was higher (1.9–4.4 g/L), than the available RIs (1.8–3.5 g/L). D-dimer cut-off value was set at 852 µg/L fibrinogen equivalent units (FEU), higher than the proposed 500 µg/L FEU for venous thromboembolism (VTE) exclusion.ConclusionsThe applicability of the available RIs for WBC count, PT, and APTT-ratio was confirmed. However, RIs for CRP and fibrinogen differed significantly than the available common national RIs for the healthy non-athletes’ population. A higher cut-off for D-dimers should be extensively verified before implementation for VTE diagnosis exclusion in a group of healthy young female athletes.  相似文献   
6.

Introduction

Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia.

Materials and methods

An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions.

Results

The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein.

Conclusions

There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia.Key words: survey, chronic kidney disease, estimated glomerular filtration rate (eGFR), albuminuria, proteinuria, creatinine, harmonization  相似文献   
7.
IntroductionThe aims of study were to assess: 1) performance specifications of Atellica 1500, 2) comparability of Atellica 1500 and Iris, 3) the accuracy of both analysers in their ability to detect bacteria.Materials and methodsCarryover, linearity, precision, reproducibility, and limit of blank (LoB) verification were evaluated for erythrocyte and leukocyte counts. ICSH 2014 protocol was used for estimation of carryover, CLSI EP15-A3 for precision, and CLSI EP17 for LoB verification. Comparison for quantitative parameters was evaluated by Bland-Altman plot and Passing-Bablok regression. Qualitative parameters were evaluated by Weighted kappa analysis. Sixty-five urine samples were randomly selected and sent for urine culture which was used as reference method to determine the accuracy of bacteria detection by analysers.ResultsAnalytical specifications of Atellica 1500 were successfully verified. Total of 393 samples were used for qualitative comparison, while 269 for sediment urinalysis. Bland-Altman analysis showed statistically significant proportional bias for erythrocytes and leukocytes. Passing-Bablok analysis for leukocytes pointed to significant constant and minor proportional difference, while it was not performed for erythrocytes due to significant data deviation from linearity. Kappa analysis resulted in the strongest agreements for pH, ketones, glucose concentrations and leukocytes, while the poorest agreement for bacteria. The sensitivity and specificity of bacteria detection were: 91 (59-100)% and 76 (66-87)% for Atellica 1500 and 46 (17-77)% and 96 (87-100)% for Iris.ConclusionThere are large differences between Atellica 1500 and Iris analysers, due to which they are not comparable and can not be used interchangeably. While there was no difference in specificity of bacteria detection, Iris analyser had greater sensitivity.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏