排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
The aim of this study was to develop an exercise protocol to simulate tennis matchplay on a 'category 2' surface. Match analyses were used to form the basis for the design of the protocol. The protocol involved playing against a tennis ball serving machine. Part A of the protocol comprised 92 min 46 s of simulated tennis matchplay; Part B consisted of continuous hitting to the point of 'volitional fatigue' or when the required hitting frequency for two consecutive ball feeds could no longer be maintained. Ten elite tennis players (5 males, 5 females) volunteered to participate in the study, which was performed on an indoor tennis court (Matchplay?, En-Tout-Cas)?. Their age, body mass and estimated maximal oxygen uptake were as follows: males, 21.7±1.0 years, 73.6±2.6 kg and 58.0±1.7 ml?·?kg?1?·?min?1, respectively; females, 21.9±1.3 years, 62.3±2.0 kg and 42.2±0.7 ml?·?kg?·?min?1, respectively (mean±). Heart rate, change in body mass and time to volitional fatigue were monitored. The heart rate responses of the participants to the simulated matchplay (range: 140-157 beats?·?min?1, 73-81% peak heart rate) were consistent with the results of previous studies, for 'actual' matchplay. This protocol was successful in simulating similar physiological responses in Part A to 'actual' matchplay on a 'category 2' surface, in a controlled environment; it was also a sensitive evaluation tool of skilled performance in Part B. The current protocol may be used as a baseline protocol for studying the influence of, for example, training and dietary intervention on performance. 相似文献
2.
Ghinea R Ugarte-Alvan L Yebra A Pecho OE Paravina RD Perez Mdel M 《Journal of Zhejiang University. Science. B》2011,12(7):552-562
This study deals with the influence of surface roughness on the color of resin composites. Ten resin composites (microfilled,
hybrid, and microhybrid) were each polished with 500-grit, 1 200-grit, 2 000-grit, and 4 000-grit SiC papers. The roughness
parameter (R
a) was measured using a Plμ confocal microscope, and field-emission scanning electron microscope (Fe-SEM) images were used
to investigate filler morphology. Color was measured using a spectroradiometer and a D65 standard illuminant (geometry diffuse/0°
specular component excluded (SCE) mode). Surface roughness decreased with grit number and was not influenced by filler size
or size distribution. A significant influence of R
a on lightness (L*) was found. Lightness increased with decreases in roughness, except for specimens that underwent polishing procedure 4 (PP4;
500-grit, 1 200-grit, 2 000-grit, and 4 000-grit SiC papers consecutively). Generally, it was found that surface roughness
influenced the color of resin composites. The composites that underwent PP1 (500-grit SiC paper) exhibited significant differences
in chroma (C*), hue (h°), and lightness (L*) compared to composites that underwent PP3 (500-grit, 1 200-grit, and 2 000-grit SiC papers consecutively) and PP4. Color
difference (ΔE*) between the polishing procedures was within acceptability thresholds in dentistry. 相似文献
1