首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this study was to predict indoor rowing performance in 12 competitive female rowers (age 21.3 +/- 3.6 years, height 1.68 +/- 0.54 m, body mass 67.1 +/- 11.7 kg; mean +/- s) using a 30 s rowing sprint, maximal oxygen uptake and the blood lactate response to submaximal rowing. Blood lactate and oxygen uptake (VO2) were measured during a discontinuous graded exercise test on a Concept II rowing ergometer incremented by 25 W for each 2 min stage; the highest VO2 measured during the test was recorded as VO2max (mean = 3.18 +/- 0.35 l.min-1). Peak power (380 +/- 63.2 W) and mean power (368 +/- 60.0 W) were determined using a modified Wingate test protocol on the Concept II rowing ergometer. Rowing performance was based on the results of the 2000 m indoor rowing championship in 1997 (466.8 +/- 12.3 s). Laboratory testing was performed within 3 weeks of the rowing championship. Submitting mean power (Power), the highest and lowest five consecutive sprint power outputs (Maximal and Minimal), percent fatigue in the sprint test (Fatigue), VO2max (l.min-1), VO2max (ml.kg-1.min-1), VO2 at the lactate threshold, power at the lactate threshold (W), maximal lactate concentration, lactate threshold (percent VO2max) and VEmax (l.min-1) to a stepwise multiple regression analysis produced the following model to predict 2000 m rowing performance: Time2000 = -0.163 (Power) -14.213.(VO2max l.min-1) +0.738.(Fatigue) 7.259 (R2 = 0.96, standard error = 2.89). These results indicate that, in the women studied, 75.7% of the variation in 2000 m indoor rowing performance time was predicted by peak power in a rowing Wingate test, while VO2max and fatigue during the Wingate test explained an additional 12.1% and 8.2% of the variance, respectively.  相似文献   

2.
Coaches, sport scientists and researchers assess rowing performance on-water and on a variety of ergometers. Ergometers are frequently used because of the easier assessment environment. However, there is limited information on the ability of rowers to reproduce mean power or time-trial time when using different rowing ergometers (Concept II and RowPerfect) or completing tests over different distances (500 m versus 2000 m races). To test the efficacy of an intervention on a rower's ability to produce power, or to monitor that ability, it is essential to determine a reliable rowing performance test. The per cent standard error of measurement in performance (assessed by mean power and time-trial time) of fifteen national standard rowers was determined for five repeated 500 m and two repeated 2000 m races on a Concept II and RowPerfect ergometer. The per cent standard error of measurement (% SEM) in mean power between 5x500m races, regardless of gender, was 2.8% (95% confidence limits (CL)=2.3 to 3.4%) for the Concept II ergometer and 3.3% (95% CL=2.5 to 3.9%) for the RowPerfect ergometer (n = 15). Over 2000 m the per cent standard error of measurement in mean power was 1.3% (95% CL 0.9 to 2.9%) for the Concept II ergometer and 3.3% (95% CL 2.2 to 7.0%) for the RowPerfect ergometer The results highlight an increase in per cent standard error of the mean during performance races of less than 2000m on the Concept II ergometer, and performance races on the RowPerfect ergometer compared with the Concept II ergometer over 500 m and 2000 m. The most appropriate protocol for testing the influence of an intervention on the ability of a rower to produce power would be 2000 m races on a Concept II ergometer.  相似文献   

3.
We evaluated (1) the test-retest reliability of the Wingate test conducted on a rowing ergometer, and (2) the sensitivity of this test in determining the differences in performance attained by 12- to 18-year-old rowers. Altogether, 297 male rowers aged 12.0-18.9 years (mean?±?s: 14.8?±?1.7) completed a maximal 30-s test on a rowing ergometer, and 80 rowers representing all age groups were retested after 5-7 days. No change was evident in participants' performance in terms of mean power output (P?=?0.726; Cohen's d?=?0.04), maximal power output (P?=?0.567; Cohen's d?=?0.06), and minimum power output (P?=?0.318; Cohen's d?=?0.11) in the second test. The intra-class correlation coefficients were high (≥0.973) and coefficients of variation were low (≤7.3%). A series of analyses of variance were used to compare the performances among 12- to 18-year-old rowers, and age-related increases in performance were evident (P?相似文献   

4.
The aim of this study was to establish the relationship between selected physiological variables of rowers and rowing performance as determined by a 2000 m time-trial on a Concept II Model B rowing ergometer. The participants were 13 male club standard oarsmen. Their mean (+/- s) age, body mass and height were 19.9+/-0.6 years, 73.1+/-6.6 kg and 180.5+/-4.6 cm respectively. The participants were tested on the rowing ergometer to determine their maximal oxygen uptake (VO2max), rowing economy, predicted velocity at VO2max, velocity and VO2 at the lactate threshold, and their velocity and VO2 at a blood lactate concentration of 4 mmol x l(-1). Percent body fat was estimated using the skinfold method. The velocity for the 2000 m performance test and the predicted velocities at the lactate threshold, at a blood lactate concentration of 4 mmol x l(-1) and at VO2max were 4.7+/-0.2, 3.9+/-0.2, 4.2+/-0.2 and 4.6+/-0.2 m x s(-1) respectively. A repeated-measures analysis of variance showed that the three predicted velocities were all significantly different from each other (P<0.05). The VO2max and lean body mass showed the highest correlation with the velocity for the 2000 m time-trial (r = 0.85). A stepwise multiple regression showed that VO2max was the best single predictor of the velocity for the 2000 m time-trial; a model incorporating VO2max explained 72% of the variability in 2000 m rowing performance. Our results suggest that rowers should devote time to the improvement of VO2max and lean body mass.  相似文献   

5.
In this study, we examined anabolic and catabolic hormone responses to a single endurance rowing training session in 12 male competitive single scull rowers. A work intensity eliciting a blood lactate concentration of 4 mmol(-1) was determined on a rowing ergometer during an endurance rowing training session lasting about 2 h (7891+/-761 s; distance covered 22.6+/-2.5 km; heart rate 136+/-7 beats x min(-1); intensity 77.4+/-3.8% of anaerobic threshold; mean +/- s). Venous blood samples were obtained before and after on-water rowing. Cortisol, testosterone and sex hormone binding globulin were measured and free testosterone and the free testosterone: cortisol ratio calculated. Blood lactate concentration did not change significantly during training (from 1.7+/-0.4 to 1.9+/-0.4 mmol x l(-1)); however, body mass was reduced (from 82.0+/-10.8 to 80.6+/-11.2 kg) and was related to the distance covered (r = -0.75). The concentrations of cortisol and testosterone did not change significantly during rowing or in the first 2 h of recovery. Free testosterone was reduced in the first 2 h of recovery, but no significant changes were observed in the free testosterone: cortisol ratio. Immediately after rowing, the concentrations of cortisol (r = 0.49) and free testosterone (r = -0.58) were related to the distance covered. Our findings indicate that a prolonged low-intensity training session results in a similar anabolic and catabolic hormone stimulus for trained rowers.  相似文献   

6.
The aim of this study was to predict indoor rowing performance in 12 competitive female rowers (age 21.3 - 3.6 years, height 1.68 - 0.54 m, body mass 67.1 - 11.7 kg; mean - s ) using a 30 s rowing sprint, maximal oxygen uptake and the blood lactate response to submaximal rowing. Blood lactate and oxygen uptake ( V O 2 ) were measured during a discontinuous graded exercise test on a Concept II rowing ergometer incremented by 25 W for each 2 min stage; the highest V O 2 measured during the test was recorded as V O 2max (mean = 3.18 - 0.35 l· min -1 ). Peak power (380 - 63.2 W) and mean power (368 - 60.0 W) were determined using a modified Wingate test protocol on the Concept II rowing ergometer. Rowing performance was based on the results of the 2000 m indoor rowing championship in 1997 (466.8 - 12.3 s). Laboratory testing was performed within 3 weeks of the rowing championship. Submitting mean power (Power), the highest and lowest five consecutive sprint power outputs (Maximal and Minimal), percent fatigue in the sprint test (Fatigue), V O 2max (l· min -1 ), V O 2max (ml·kg -1 ·min -1 ), V O 2 at the lactate threshold, power at the lactate threshold (W), maximal lactate concentration, lactate threshold (percent V O 2max ) and V E max (l·min -1 ) to a stepwise multiple regression analysis produced the following model to predict 2000 m rowing performance: Time 2000 =- 0.163 (Power)14.213 ·( V O 2max l· min -1 ) + 0.738· (Fatigue) + 567.259 ( R 2 = 0.96, standard error = 2.89). These results indicate that, in the women studied, 75.7% of the variation in 2000 m indoor rowing performance time was predicted by peak power in a rowing Wingate test, while V O 2max and fatigue during the Wingate test explained an additional 12.1% and 8.2% of the variance, respectively.  相似文献   

7.
Abstract

We evaluated (1) the test–retest reliability of the Wingate test conducted on a rowing ergometer, and (2) the sensitivity of this test in determining the differences in performance attained by 12- to 18-year-old rowers. Altogether, 297 male rowers aged 12.0–18.9 years (mean ± s: 14.8 ± 1.7) completed a maximal 30-s test on a rowing ergometer, and 80 rowers representing all age groups were retested after 5–7 days. No change was evident in participants' performance in terms of mean power output (P = 0.726; Cohen's d = 0.04), maximal power output (P = 0.567; Cohen's d = 0.06), and minimum power output (P = 0.318; Cohen's d = 0.11) in the second test. The intra-class correlation coefficients were high (≥0.973) and coefficients of variation were low (≤7.3%). A series of analyses of variance were used to compare the performances among 12- to 18-year-old rowers, and age-related increases in performance were evident (P < 0.001; Cohen's d = 1.91–1.96). The age-related increases in performance were similar, although reduced, when the effects of body mass were partitioned out when using analysis of covariance (P < 0.001; Cohen's d = 0.82–0.85). The results suggest that: (1) the described test is reliable and can be used for maximal-intensity exercise assessment in youth rowing, and (2) it discriminates performance among 12- to-18-year-old rowers.  相似文献   

8.
The aims of this study were to examine the use of the critical velocity test as a means of predicting 2000-m rowing ergometer performance in female collegiate rowers, and to study the relationship of selected physiological variables on performance times. Thirty-five female collegiate rowers (mean ± s: age 19.3 ± 1.3 years; height 1.70 ± 0.06 m; weight 69.5 ± 7.2 kg) volunteered to participate in the study. Rowers were divided into two categories based on rowing experience: varsity (more than 1 year collegiate experience) and novice (less than 1 year collegiate experience). All rowers performed two continuous graded maximal oxygen consumption tests (familiarization and baseline) to establish maximal oxygen uptake (VO(2max)), peak power output, and power output at ventilatory threshold. Rowers then completed a critical velocity test, consisting of four time-trials at various distances (400 m, 600 m, 800 m, and 1000 m) on two separate days, with 15 min rest between trials. Following the critical velocity test, rowers completed a 2000-m time-trial. Absolute VO(2max) was the strongest predictor of 2000-m performance (r = 0.923) in varsity rowers, with significant correlations also observed for peak power output and critical velocity (r = 0.866 and r = 0.856, respectively). In contrast, critical velocity was the strongest predictor of 2000-m performance in novice rowers (r = 0.733), explaining 54% of the variability in performance. These findings suggest the critical velocity test may be more appropriate for evaluating performance in novice rowers.  相似文献   

9.
Rowers need to combine high sprint and endurance capacities. Muscle morphology largely explains muscle power generating capacity, however, little is known on how muscle morphology relates to rowing performance measures. The aim was to determine how muscle morphology of the vastus lateralis relates to rowing ergometer performance, sprint and endurance capacity of Olympic rowers. Eighteen rowers (12♂, 6♀, who competed at 2016 Olympics) performed an incremental rowing test to obtain maximal oxygen consumption, reflecting endurance capacity. Sprint capacity was assessed by Wingate cycling peak power. M. vastus lateralis morphology (volume, physiological cross-sectional area, fascicle length and pennation angle) was derived from 3-dimensional ultrasound imaging. Thirteen rowers (7♂, 6♀) completed a 2000-m rowing ergometer time trial. Muscle volume largely explained variance in 2000-m rowing performance (R2 = 0.85), maximal oxygen consumption (R2 = 0.65), and Wingate peak power (R2 = 0.82). When normalized for differences in body size, maximal oxygen consumption and Wingate peak power were negatively related in males (r = ?0.94). Fascicle length, not physiological cross-sectional area, attributed to normalized peak power. In conclusion, vastus lateralis volume largely explains variance in rowing ergometer performance, sprint and endurance capacity. For a high normalized sprint capacity, athletes may benefit from long fascicles rather than a large physiological cross-sectional area.  相似文献   

10.
This case study reports the results of a 12-year (2005–2016) follow-up study of two Olympic champion rowers. The rowers were prospective athletes at the junior level when the study began, and we monitored their relevant physiological and performance data annually. Our findings indicated that their V?O2max gradually increased up to about 22 years of age and leveled off at a value of approximately 7 l·min?1 with minimal fluctuations thereafter. However, the variables that directly influence the V?O2max changed. There was an age-related decline in maximal heart rate of about 0.5 beats·year?1, while oxygen pulse, which serves as an indirect measure of stroke volume, correspondingly increased by about 1 ml O2·beat?1 per year, allowing the athletes to maintain exceptional V?O2max values. Maximal minute power of the studied rowers, derived each year from their ramp-wise tests, closely resembled the mean power output sustained during the 2000-m all-out tests on a rowing ergometer. A 12-year improvement of 28% and 33% occurred for the mean power output sustained over 2000 and 6000-m on a rowing ergometer, respectively. The findings contribute to the body of knowledge on athletes representing the true elites of their respective sports.  相似文献   

11.
Graded exercise tests are commonly used to assess peak physiological capacities of athletes. However, unlike time trials, these tests do not provide performance information. The aim of this study was to examine the peak physiological responses of female outrigger canoeists to a 1000-m ergometer time trial and compare the time-trial performance to two graded exercise tests performed at increments of 7.5 W each minute and 15 W each two minutes respectively. 17 trained female outrigger canoeists completed the time trial on an outrigger canoe ergometer with heart rate (HR), stroke rate, power output, and oxygen consumption (VO2) determined every 15 s. The mean (+/- s) time-trial time was 359 +/- 33 s, with a mean power output of 65 +/- 16 W and mean stroke rate of 56 +/- 4 strokes min(-1). Mean values for peak VO2, peak heart rate, and mean heart rate were 3.17 +/- 0.67 litres min(-1), 177 +/- 11 beats min(-1), and 164 +/- 12 beats min(-1) respectively. Compared with the graded exercise tests, the time-trial elicited similar values for peak heart rate, peak power output, peak blood lactate concentration, and peak VO2. As a time trial is sport-specific and can simultaneously quantify sprint performance and peak physiological responses in outrigger canoeing, it is suggested that a time trial be used by coaches for crew selection as it doubles as a reliable performance measure and a protocol for monitoring peak aerobic capacity of female outrigger canoeists.  相似文献   

12.
13.
The rowing stroke is a leg-driven action, in which forces developed by the lower limbs provide a large proportion of power delivered to the oars. In terms of both performance and injury, it is important to initiate each stroke with powerful and symmetrical loading of the foot stretchers. The aims of this study were to assess the reliability of foot force measured by footplates developed for the Concept2 indoor ergometer and to examine the magnitude and symmetry of bilateral foot forces in different groups of rowers. Five heavyweight female scullers, six heavyweight female sweep rowers, and six lightweight male (LWM) rowers performed an incremental step test on the Concept2 ergometer. Vertical, horizontal, and resultant forces were recorded bilaterally, and asymmetries were quantified using the absolute symmetry index. Foot force was measured with high consistency (coefficient of multiple determination>0.976 ± 0.010). Relative resultant, vertical, and horizontal forces were largest in LWM rowers, whilst average foot forces significantly increased across stroke rates for all three groups of rowers. Asymmetries ranged from 5.3% for average resultant force to 28.9% for timing of peak vertical force. Asymmetries were not sensitive to stroke rate or rowing group, however, large inter-subject variability in asymmetries was evident.  相似文献   

14.
Oar force and oar angle data resulting from a 6‐min maximal rowing ergometer test undertaken by novice (n = 9), good (n ‐ 23) and national (n = 9) level male rowers, were used to identify biomechanical performance variables which accurately discriminated between rowers of differing ability levels. The variables included two work capacity measures, mean propulsive power output per kilogram of body mass (W kg‐1) and propulsive work consistency (%), and two skill variables, stroke‐to‐stroke consistency (%) and stroke smoothness (%). Discriminant function analysis indicated the presence of two functions, both of which clearly indicated the importance of mean propulsive power output per kilogram of body mass as a discriminating variable. Function 2 gave greater weight to stroke‐to‐stroke consistency and stroke smoothness than function 1; however, function 1 was the most powerful discriminator. Classification procedures were used to predict the ability level to which a rower most likely belonged and involved defining the ‘distance’ between each rower and each ability level centroid, with the rower being classified into the ‘nearest’ ability level. These procedures indicated that 100% of the elite, 73.9% of the good, 88.9% of the novice and 82.9% of all rowers were correctly classified into their respective skill levels. Stepwise discriminant analysis included the variables in the following order: mean propulsive power output per kilogram of body mass, stroke‐to‐stroke consistency, stroke smoothness and propulsive work consistency (P < 0.001). The results of this study indicate that biomechanical performance variables related to rowing capacity and skill may be identified and used to discriminate accurately between rowers of differing skill levels, and that, of these variables, propulsive work consistency is the least effective discriminator.  相似文献   

15.
Lumbar spine injury in rowers is common and ergometer rowing has been cited as a risk factor for this injury. The purpose of this study is to compare lumbar kinematics between ergometer and single scull rowing and to examine the effect of fatigue on kinematics. The sagittal lumbar spine motion of 19 elite male rowers (lumbar spine injury free in the previous six months) was measured with an electrogoniometer during a ‘step test’ on an ergometer and in a single sculling boat. Maximum range of lumbar flexion was recorded in standing for reference. Power output and heart rate were recorded during the ergometer tests. Heart rate was used as a surrogate for power output in the sculling test. Maximum lumbar flexion increased during the step test and was significantly greater on the ergometer (4.4° ± 0.9°change), compared with the boat (+1.3° ± 1.1°change), (3.1°difference, p = 0.035). Compared to the voluntary range of motion, there is an increase of 11.3% (ergometer) and 4.1% (boat). Lumbar spine flexion increases significantly during the course of an ergometer trial while changes in a sculling boat were minimal. Such differences may contribute to the recent findings linking ergometer use to lower-back injury.  相似文献   

16.
Bilateral leg extension power and fat-free mass in young oarsmen   总被引:1,自引:0,他引:1  
We evaluated the impact of bilateral leg extension power and fat-free mass on 2000 m rowing ergometer performance in 332 young oarsmen (age 21+/-2 years, height 1.76+/-0.05 m, body mass 62+/-6 kg; mean+/-s). The 2000 m rowing performance time was correlated with height (1.62-1.93 m; R2=0.23, P<0.001), body mass (53-95 kg; R2=0.53, P<0.001), fat-free mass (47-82 kg; R2=0.58, P<0.001) and bilateral leg extension power (1202-3302 W; R2=0.38, P<0.001). Multiple regression analysis selected fat-free mass and bilateral leg extension power as regressor variables. Fat-free mass explained 58% of the variability in rowing performance and the inclusion of bilateral leg extension power improved the power of prediction by 5%. The results suggest that rowing involves almost every muscle in the body and that bilateral leg extension power is very important during this activity.  相似文献   

17.
本文观察了16名女子赛艇运动员30周训练期间有氧和无氧代谢运动能力的变化。前13周以力量训练为主,后17周以专项训练为主。观察发现过多力量训练无助于有氧能力发展,在专项训练期,应保持足够强度才能在发展有氧能力的同时提高最大乳酸值。  相似文献   

18.
ABSTRACT

Post-activation potentiation likely acutely improves power-based performance; however, few studies have demonstrated improved endurance performance. Forty collegiate female rowers performed isometric potentiating (ISO), dynamic potentiating (DYN) and control (CON) warm-up protocols on a rowing ergometer, followed by a three-minute all-out test to evaluate their total distance, peak power, mean power, critical power, anaerobic working capacity (W’) and stroke rate. Fifteen-second splits were also analysed. ISO consisted of 5 × 5-second static muscle actions with the ergometer handle rendered immovable with a nylon strap, while DYN consisted of 2 × 10-second all-out rowing bouts, separated by a 2-minute rest interval. The participants were divided into high and low experience groups by median experience level (3.75 years) for statistical analysis. Significant differences (DYN > CON; p < 0.05) were found for distance (+5.6 m), mean power (+5.9 W) and W’ (+1561.6 J) for more experienced rowers (n = 19) and no differences for less experienced rowers (n = 18). Mean power in DYN was significantly greater than CON and ISO in the 15–30, 30–45, 45–60 and 60–75 second intervals independent of experience level. These results suggest that DYN may benefit experienced female rowers and that these strategies might benefit a greater power output over shorter distances regardless of experience.  相似文献   

19.
Abstract

The aims of this study were to examine the use of the critical velocity test as a means of predicting 2000-m rowing ergometer performance in female collegiate rowers, and to study the relationship of selected physiological variables on performance times. Thirty-five female collegiate rowers (mean ± s: age 19.3 ± 1.3 years; height 1.70 ± 0.06 m; weight 69.5 ± 7.2 kg) volunteered to participate in the study. Rowers were divided into two categories based on rowing experience: varsity (more than 1 year collegiate experience) and novice (less than 1 year collegiate experience). All rowers performed two continuous graded maximal oxygen consumption tests (familiarization and baseline) to establish maximal oxygen uptake ([Vdot]O2max), peak power output, and power output at ventilatory threshold. Rowers then completed a critical velocity test, consisting of four time-trials at various distances (400 m, 600 m, 800 m, and 1000 m) on two separate days, with 15 min rest between trials. Following the critical velocity test, rowers completed a 2000-m time-trial. Absolute [Vdot]O2max was the strongest predictor of 2000-m performance (r = 0.923) in varsity rowers, with significant correlations also observed for peak power output and critical velocity (r = 0.866 and r = 0.856, respectively). In contrast, critical velocity was the strongest predictor of 2000-m performance in novice rowers (r = 0.733), explaining 54% of the variability in performance. These findings suggest the critical velocity test may be more appropriate for evaluating performance in novice rowers.  相似文献   

20.
The effect of anthropometric differences in shank to thigh length ratio upon timing and magnitude of joint power production during the drive phase of the rowing stroke was investigated in 14 elite male rowers. Rowers were tested on the RowPerfect ergometer which was instrumented at the handle and foot stretcher to measure force generation, and a nine segment inverse dynamics model used to calculate the rower's joint and overall power production. Rowers were divided into two groups according to relative shank thigh ratio. Time to half lumbar power generation was significantly earlier in shorter shank rowers (p = 0.028) compared to longer shank rowers, who showed no lumbar power generation during the same period of the drive phase. Rowers with a relatively shorter shank demonstrated earlier lumbar power generation during the drive phase resulting from restricted rotation of the pelvic segment requiring increased lumbar extension in these rowers. Earlier lumbar power generation and extension did not appear to directly affect performance measures of the short shank group, and so can be attributed to a technical adaptation developed to maximise rowing performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号