首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The purpose of this study was to quantify the reliability of kinematic and kinetic variables using a sample of pre-peak-height-velocity (PHV) male athletes sprinting on a non-motorised treadmill. Following variables were measured and their normative data presented, average and peak velocity, average and peak power, average and peak horizontal force, average and peak vertical force, average step frequency, average step length, average work. Twenty-five participants performed three 5-s all-out sprints from a standing split start on a non-motorised treadmill on three separate occasions. Per cent change in the means (-3.66 to 3.35%) and coefficients of variation (0.56–7.81%) were thought reliable for all variables. However, average step rate, average horizontal force and average vertical force did not meet the standards (≥0.70) set for acceptable intraclass correlation coefficients (ICC). Due to the homogeneous group, it was expected to receive low ICC values. Therefore, youth sprinting performance can be tested reliably on a non-motorised treadmill, especially if the per cent change in the mean and CV are deemed the important reliability measures. Normative data are given for the participant’s age as well as their maturity level for kinematic and kinetic variables.  相似文献   

2.
The reliability of grinding performance was assessed in 18 current Emirates Team New Zealand America's Cup sailors in two test sessions separated by 5 h using a custom-built ergometer. Sixteen different grinding conditions that varied by load (Light 39 N x m, Moderate 48 N x m, Heavy 68 N x m), deck heel (Flat 0 degrees control, Downhill 25 degrees, Uphill 25 degrees, Right 25 degrees, Left 25 degrees), and grinding direction (forwards, backwards) were assessed using peak power and external work over 5 s during maximal-effort 8-s grinds. Reliability statistics included the difference in mean (M(diff)), standard error of measurement (SEM), and intraclass correlation coefficients (ICC). External work (SEM = 1.6-6.9%; ICC = 0.91-0.99) was a more consistent performance measure than peak power (SEM = 1.3-9.6%; ICC = 0.84-0.99) across all test conditions. Testing under different load conditions resulted in external work SEMs of 1.6-3.9% with performance more reliable in lighter load conditions. Grinding performance during different heel conditions was less reliable (external work SEMs = 4.6-6.9%). Grinding direction (forward or backward) did not appear to affect performance reliability, although external work was 10-15% higher in forward grinding. Reliability is acceptable across various loads, but testing under different heel conditions may need some protocol development to allow the detection of smaller differences in performance.  相似文献   

3.
The aim of this study was to evaluate the reliability of two long jump tasks and their ability to predict 10 m sprint performance in elite adolescent female athletes. Eight junior national-level female track and field athletes completed three standing (SLJ) and reactive long jumps (RLJ) on portable force plates, followed by three 10 m sprints. Intra-class correlation coefficients (ICC) and coefficients of variation (CV) were calculated to examine reliability. Linear regression results identified the best predictor of average and best 10 m sprint time from the jump kinematic and kinetic measures. The ICCs and CVs indicated good reliability for the majority of kinetic measures however, better reliability was reported for the SLJ. The SLJ was a good predictor of best and average 10 m sprint time, with average horizontal power the best predictor of performance (best; R2 = 0.751, p = 0.003, Standard Error of Estimate (SEE)% = 2.2 average; R2 = 0.708, p = 0.005, SEE% = 2.5).  相似文献   

4.
The purpose of this study was to quantify the inter-session reliability of force–velocity–power profiling and estimated maximal strength in youth. Thirty-six males (11–15 years old) performed a ballistic supine leg press test at five randomized loads (80%, 100%, 120%, 140%, and 160% body mass) on three separate occasions. Peak and mean force, power, velocity, and peak displacement were collected with a linear position transducer attached to the weight stack. Mean values at each load were used to calculate different regression lines and estimate maximal strength, force, velocity, and power. All variables were found reliable (change in the mean [CIM] = ? 1 to 14%; coefficient of variation [CV] = 3–18%; intraclass correlation coefficient [ICC] = 0.74–0.99), but were likely to benefit from a familiarization, apart from the unreliable maximal force/velocity ratio (CIM = 0–3%; CV = 23–25%; ICC = 0.35–0.54) and load at maximal power (CIM = ? 1 to 2%; CV = 10–13%; ICC = 0.26–0.61). Isoinertial force–velocity–power profiling and maximal strength in youth can be assessed after a familiarization session. Such profiling may provide valuable insight into neuromuscular capabilities during growth and maturation and may be used to monitor specific training adaptations.  相似文献   

5.
ABSTRACT

This study aimed to compare the reliability and magnitude of velocity variables between 3 variants of the bench press (BP) exercise in participants with and without BP training experience. Thirty males, 15 with and 15 without BP experience, randomly performed 3 variants of the BP on separate sessions: (I) concentric-only, (II) fast-eccentric and (III) controlled-eccentric. The mean velocity (MV) and maximum velocity (Vmax) of the concentric phase were collected against 3 loads (≈30%1RM, 50%1RM, and 75%1RM) with a linear velocity transducer. Reliability was high regardless of the variable, BP variant, and load (coefficient of variation [CV] ≤ 4.47%, intraclass correlation coefficient [ICC] ≥ 0.87). The comparison of the CVs suggested a higher reliability for the fast-eccentric BP (8 out of 12 comparisons), followed by the concentric-only BP (5 out of 12 comparisons), and finally the controlled-eccentric BP (never provided a higher reliability). No differences in reliability were observed between experienced (CV ≤ 4.71%; ICC ≥ 0.79) and non-experienced (CV ≤ 6.29%; ICC ≥ 0.76) participants. The fast-eccentric BP provided the highest MV (p < 0.05) and no differences were observed for Vmax. These results support the assessment of movement velocity during the fast-eccentric BP even in participants without experience.  相似文献   

6.
7.
The purpose of this study was to determine the between day reliability of power-time measures calculated with data collected using the linear position transducer or the force plate independently, or a combination of the two technologies. Twenty-five male rugby union players performed three jump squats on two occasions one week apart. Ground reaction forces were measured via a force plate and position data were collected using a linear position transducer. From these data, a number of power-time variables were calculated for each method. The force plate, linear position transducer and a combined method were all found to be a reliable means of measuring peak power (ICC = 0.87-0.95, CV = 3.4%-8.0%). The absolute consistency of power-time measures varied between methods (CV = 8.0%-53.4%). Relative consistency of power-time measures was generally comparable between methods and measures, and for many variables was at an acceptable level (ICC = 0.77-0.94). Although a number of time-dependent power variables can be reliably calculated from data acquired from the three methods investigated, the reliability of a number of these measures is below that which is acceptable for use in research and for practical applications.  相似文献   

8.
This study aimed to explore the strength of the force–velocity (FV) relationship of lower limb muscles and the reliability of its parameters (maximum force [F0], slope [a], maximum velocity [V0], and maximum power [P0]). Twenty-three men were tested in two different jump types (squat and countermovement jump: SJ and CMJ), performed under two different loading conditions (free weight and Smith machine: Free and Smith) with 0, 17, 30, 45, 60, and 75?kg loads. The maximum and averaged values of F and V were obtained for the FV relationship modelling. All FV relationships were strong and linear independently whether observed from the averaged across the participants (r?≥?0.98) or individual data (r?=?0.94–0.98), while their parameters were generally highly reliable (F0 [CV: 4.85%, ICC: 0.87], V0 [CV: 6.10%, ICC: 0.82], a [CV: 10.5%, ICC: 0.81], and P0 [CV: 3.5%, ICC: 0.93]). Both the strength of the FV relationships and the reliability of their parameters were significantly higher for (1) the CMJ over the SJ, (2) the Free over the Smith loading type, and (3) the maximum over the averaged F and V variables. In conclusion, although the FV relationships obtained from all the jumps tested were linear and generally highly reliable, the less appropriate choice for testing the FV relationship could be through the averaged F and V data obtained from the SJ performed either in a Free weight or in a Smith machine. Insubstantial differences exist among the other combinations tested.  相似文献   

9.
This study aimed to assess the validity and reliability of jump assessments using the MyJump2 application. Eleven junior athletes (15 ± 1.4 years) performed five countermovement (CMJ) and drop jumps (DJ) measured simultaneously by a force platform and MyJump2. Additionally, intra- and inter-day reliability was assessed over two sessions, 7 days apart. Extremely high agreement between MyJump2 and the force platform (intra-class correlation coefficient, ICC ≥ 0.99) and the intra- and inter-operator agreement (ICC = 0.98–0.99) confirmed the validity and reliability of MyJump2. Mean typical errors (coefficient of variation percentage, CV%) within the first and second sessions were 4.9% and 4.5% respectively for CMJs, and 8.0% to 11.8% for DJ outcomes. CMJ height held acceptable inter-day reliability (CV < 10%; ICC > 0.8), while DJ did not. Results supported MyJump2 to be a valid and reliable tool for assessing jumps; however, with variability in DJs in this cohort, appropriate caution should be taken if including in a junior assessment battery.  相似文献   

10.
There is a need for reliable analysis techniques for kinetic data for coaches and sport scientists who employ athlete monitoring practices. The purpose of the study was: (1) to determine intra- and inter-rater reliability within a manual-based kinetic analysis program; and (2) to determine test-retest reliability of an algorithm-based kinetic analysis program. Five independent raters used a manual analysis program to analyse 100 isometric mid-thigh pull (IMTP) trials obtained from previously collected data. Each trial was analysed three times. The same IMTP trials were analysed using an algorithm-based analysis software. Variables measured were peak force, rate of force development from 0 to 50 ms (RFD50) and RFD from 0 to 200 ms (RFD200). Intraclass correlation coefficients (ICC) and coefficient of variation (CV) were used to assess intra- and inter-rater reliability. Nearly perfect reliability was observed for the manual-based (ICC > 0.92). However, poor intra- and inter-rater CV was observed for RFD (CV > 16.25% and CV > 32.27%, respectively). The algorithm-based method resulted in perfect reliability in all measurements (ICC = 1.0, CV = 0%). While manual methods of kinetic analysis may provide sufficient reliability, the perfect reliability observed within the algorithm-based method in the current study suggest it is a superior method for use in athlete monitoring programs.  相似文献   

11.
The reliability of grinding performance was assessed in 18 current Emirates Team New Zealand America's Cup sailors in two test sessions separated by 5 h using a custom-built ergometer. Sixteen different grinding conditions that varied by load (Light 39 N·m, Moderate 48 N·m, Heavy 68 N·m), deck heel (Flat 0° control, Downhill 25°, Uphill 25°, Right 25°, Left 25°), and grinding direction (forwards, backwards) were assessed using peak power and external work over 5 s during maximal-effort 8-s grinds. Reliability statistics included the difference in mean (Mdiff), standard error of measurement (SEM), and intraclass correlation coefficients (ICC). External work (SEM = 1.6–6.9%; ICC = 0.91–0.99) was a more consistent performance measure than peak power (SEM = 1.3–9.6%; ICC = 0.84–0.99) across all test conditions. Testing under different load conditions resulted in external work SEMs of 1.6–3.9% with performance more reliable in lighter load conditions. Grinding performance during different heel conditions was less reliable (external work SEMs = 4.6–6.9%). Grinding direction (forward or backward) did not appear to affect performance reliability, although external work was 10–15% higher in forward grinding. Reliability is acceptable across various loads, but testing under different heel conditions may need some protocol development to allow the detection of smaller differences in performance.  相似文献   

12.
The aim of this study was to evaluate the reliability of two long jump tasks and their ability to predict 10 m sprint performance in elite adolescent female athletes. Eight junior national-level female track and field athletes completed three standing (SLJ) and reactive long jumps (RLJ) on portable force plates, followed by three 10 m sprints. Intra-class correlation coefficients (ICC) and coefficients of variation (CV) were calculated to examine reliability. Linear regression results identified the best predictor of average and best 10 m sprint time from the jump kinematic and kinetic measures. The ICCs and CVs indicated good reliability for the majority of kinetic measures however, better reliability was reported for the SLJ. The SLJ was a good predictor of best and average 10 m sprint time, with average horizontal power the best predictor of performance (best; R 2 = 0.751, p = 0.003, Standard Error of Estimate (SEE)% = 2.2 average; R 2 = 0.708, p = 0.005, SEE% = 2.5).  相似文献   

13.
PurposeThis review aimed to synthesize previous findings on the test–retest reliability of the 30–15 Intermittent Fitness Test (IFT).MethodsThe literature searches were performed in 8 databases. Studies that examined the test–retest reliability of the 30–15 IFT and presented the intraclass correlation coefficient (ICC) and/or the coefficient of variation (CV) for maximal velocity and/or peak heart rate were included. The consensus-based standards for the selection of health measurement instruments (COSMIN) checklist was used for the assessment of the methodological quality of the included studies.ResultsSeven studies, with a total of 10 study groups, explored reliability of maximal velocity assessed by the 30–15 IFT. ICCs ranged from 0.80 to 0.99, where 70% of ICCs were ≥0.90. CVs for maximal velocity ranged from 1.5% to 6.0%. Six studies, with a total of 7 study groups, explored reliability of peak heart rate as assessed by the 30–15 IFT. ICCs ranged from 0.90 to 0.97 (i.e., all ICCs were ≥0.90). CVs ranged from 0.6% to 4.8%. All included studies were of excellent methodological quality.ConclusionFrom the results of this systematic review, it can be concluded that the 30–15 IFT has excellent test–retest reliability for both maximal velocity and peak heart rate. The test may, therefore, be used as a reliable measure of fitness in research and sports practice.  相似文献   

14.
This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants’ feet. The velocity of the ‘body + lifted mass’ system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p < 0.05). Within sessions and between sessions, mean and peak forces during DHP showed a strong agreement (CV < 3%, ICC > 0.94), mean and peak velocities showed a good agreement (CV < 9%, 0.78 < ICC < 0.92). It was concluded that DHP performance and its force-velocity relationships are highly reliable and can therefore be utilised as a tool to characterise individuals’ muscular profiles.  相似文献   

15.
Muscle imbalance and deficit are key parameters for guiding rehabilitation and sports sessions and avoiding injuries. However, the high cost and non-portable nature of most instruments employed for muscle strength assessment frequently hamper an affordable evaluation in field conditions. This study evaluated the validity and reliability of a low-cost digital dynamometer to assess the maximal isometric strength of upper limb muscles. Fourteen physically active volunteers performed the main movements of the upper limb at maximal isometric strength: flexion-extension, internal-external rotation and abduction-adduction of the shoulder; and flexion-extension of both elbow and wrist. Validity was examined by comparing the strength values from the low-cost digital dynamometer and those measured by an isokinetic dynamometer, assumed as the gold standard. The correlation between both devices was perfect (r > 0.913), while Bland-Altman plots showed absolute agreement between both devices, the maximum range of the values of bias was ?0.99–1.00 N in wrist extension. Inter-tester and intra-tester reliability were excellent for all movements (ICC ≥ 0.855). The low-cost digital dynamometer showed strong validity and excellent reliability in assessing maximal isometric strength during the main movements of the upper limb. Professionals may use it for an affordable isometric muscle strength assessment in field situations.  相似文献   

16.
Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test–retest reliability. Talent identification test–retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland–Altman plots (Limits of Agreement). Spearman’s correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.  相似文献   

17.
In Paralympic seated throwing events, the athlete can throw with and without an assistive pole. This study aimed to identify and compare performance-related kinematic variables associated with both seated throwing techniques. Twenty-nine non-disabled males (21.9 ± 2.6 years) performed 12 maximal throws using a 1-kg ball in two conditions (no-pole and pole). Automatic 3D-kinematic tracking (150 Hz) and temporal data were acquired. There was no significant difference between ball speeds at the point of release between conditions (no-pole = 12.8 ± 1.6 m/s vs. pole = 12.9 ± 1.5 m/s). There were four kinematic variables that were strongly correlated with ball speed when throwing with or without an assistive pole. These variables were elbow flexion at the start phase (pole r = .39 and no-pole r = .41), maximum shoulder external rotation angular velocity during the arm cocking phase (pole r = .42), maximum shoulder internal rotation angular velocity during the arm acceleration phase (pole r = .47), and should internal rotation angular velocity at the instant of ball release (pole r = .40). The pole clearly influenced the throwing technique with all four strongly correlated variables identified in this condition, compared to only one during the no-pole condition. When using the pole, participants produced significantly higher shoulder internal rotation angular velocities during the arm acceleration phase (pole = 367 ± 183°/s vs. no-pole = 275 ± 178°/s, p < .05) and at the instant of ball release (pole = 355 ± 115°/s vs. no-pole = 264 ± 120°/s, p < .05), compared to throwing without the pole. These findings have implications for the development of evidence-based classification systems in Paralympic seated throwing, and facilitate research that investigates the impact of impairment on seated throwing performance.  相似文献   

18.
ABSTRACT

Anaerobic performance in youth has received little attention partly due to the lack of a “gold-standard” measurement. However, force-velocity-power (F-v-P) profiling recently showed high reliability and validity in trained adults. Therefore, the aim was to determine the reliability of F-v-P profiling in children and adolescents. Seventy-five children (60 boys, 15 girls; age: 14.1 ± 2.6 years) completed three 30 m sprints. Velocity was measured at 46.875 Hz using a radar device. The F-v-P profile was fitted to a velocity-time curve allowing instantaneous power variables to be calculated. Reliability was assessed using the intra-class correlation coefficient (ICC), coefficient of variation (CV), standard error of measurement (SEM) and smallest worthwhile change (SWC). High reliability was evident for absolute peak (Ppeak) and mean power (Pmean), Ppeak and Pmean expressed relative to body mass, peak and mean velocity, 30 m sprint time, peak horizontal force (F0), relative F0, mechanical efficiency index and fatigue rate (ICC: 0.75–0.88; CV: 1.9–9.4%) with time to peak power demonstrating moderate reliability (ICC: 0.50; CV: 9.5%). The F-v-P model demonstrated at least moderate reliability for all variables. This therefore provides a potential alternative for paediatric researchers assessing sprint performance and the underlying kinetics.  相似文献   

19.
陈龙伟  王珏  高琳  石磊 《中国体育科技》2012,48(2):83-85,111
目的:对正常青年人步态的时空及运动学参数进行可靠性分析,确定步态参数的最佳测试次数,为步态测试次数的标准化提供依据.方法:利用三维运动捕捉系统采集35例正常青年人的步态时空及运动学参数;利用组内相关系数(ICC)对步态参数进行可靠性分析.结果:重复测试4次,正常青年人时空各参数的ICC值均达到0.9以上;重复测试6次,正常青年人运动学各参数的ICC值均达到0.9以上.结论:1)正常青年人每次测试取一个步态周期、重复测试4次能使时空参数达到较高的可靠性;2)同样条件下,正常青年人需要重复测试6次能使运动学参数达到较高的可靠性;3)正常青年人的时空参数的可靠性高于运动学参数.  相似文献   

20.
This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20–70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load–power relationship compared to the load–velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号