首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
教育   1篇
科学研究   1篇
体育   11篇
  2021年   1篇
  2013年   8篇
  2009年   1篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
Three studies are reported of children and youth aged 11–19 years (n?=?3478) examining the nature of beliefs about athletic ability. Drawing on related research in academic, moral and stereotyping domains, development of a psychometric instrument assessing athletic ability beliefs is detailed. Support was found for a multidimensional hierarchical structure that is invariant across age and gender. Confirmatory factor analysis revealed a structure comprising two higher-order factors of entity and incremental beliefs underpinned by beliefs that athletic ability is stable and a gift (entity), and is open to improvement and can be developed through learning (incremental). Incremental beliefs, indirectly through a task goal orientation, and entity beliefs directly, predicted self-reported amotivation towards physical education and sport. On the other hand, enjoyment of physical activity in youth was predicted directly by task orientation and incremental beliefs. Predictions concerning the moderating role of perceived competence were not supported. Our findings highlight the importance of ability beliefs and goals in understanding the determinants of physical activity in children and youth.  相似文献   
2.
The aim of this study was to assess the sensitivity of the lactate minimum speed test to changes in endurance fitness resulting from a 6 week training intervention. Sixteen participants (mean +/- s :age 23 +/- 4 years;body mass 69.7 +/- 9.1 kg) completed 6 weeks of endurance training. Another eight participants (age 23 +/- 4 years; body mass 72.7 +/-12.5 kg) acted as non-training controls. Before and after the training intervention, all participants completed: (1) a standard multi-stage treadmill test for the assessment of VO 2max , running speed at the lactate threshold and running speed at a reference blood lactate concentration of 3 mmol.l -1 ; and (2) the lactate minimum speed test, which involved two supramaximal exercise bouts and an 8 min walking recovery period to increase blood lactate concentration before the completion of an incremental treadmill test. Additionally, a subgroup of eight participants from the training intervention completed a series of constant-speed runs for determination of running speed at the maximal lactate steady state. The test protocols were identical before and after the 6 week intervention. The control group showed no significant changes in VO 2max , running speed at the lactate threshold, running speed at a blood lactate concentration of 3 mmol.l -1 or the lactate minimum speed.In the training group, there was a significant increase in VO 2max (from 47.9 +/- 8.4 to 52.2 +/- 2.7 ml.kg -1 .min -1 ), running speed at the maximal lactate steady state (from 13.3 +/- 1.7 to 13.9 +/- 1.6 km.h -1 ), running speed at the lactate threshold (from 11.2 +/- 1.8 to 11.9 +/- 1.8 km.h -1 ) and running speed at a blood lactate concentration of 3 mmol.l -1 (from 12.5 +/- 2.2 to 13.2 +/- 2.1 km.h -1 ) (all P ? 0.05). Despite these clear improvements in aerobic fitness, there was no significant difference in lactate minimum speed after the training intervention (from 11.0 +/- 0.7 to 10.9 +/- 1.7 km.h -1 ). The results demonstrate that the lactate minimum speed,when assessed using the same exercise protocol before and after 6 weeks of aerobic exercise training, is not sensitive to changes in endurance capacity.  相似文献   
3.
Extreme multistability is the coexistence of a large number of attractors which can be reached by varying initial conditions. In this paper we show how this fascinating phenomenon can be used for secure communication. The main advantage of the communication system based on extreme multistability over a conventional chaos-based communication system is its exceptionally high security. The proposed system consists of two identical six-order oscillators; one in the transmitter and another one in the receiver, each exhibiting the coexistence of a large number of chaotic attractors. The oscillators are synchronized using a private channel through one of the system variables, while the information is transmitted via a public channel through another variable. The information is encrypted by varying the initial condition of one of the state variables in the transmitter using a chaotic map, adhering message packages in a staggered form to the coexisting attractors within the same time series of another state variable, which leads to switching among the coexisting chaotic attractors. To ensure communication security, the duration of the packages is shorter than synchronization time, so that synchronization attacks are ineffective.  相似文献   
4.
The aim of this study was to assess the sensitivity of the lactate minimum speed test to changes in endurance fitness resulting from a 6 week training intervention. Sixteen participants (mean +/- s: age 23+/-4 years; body mass 69.7+/-9.1 kg) completed 6 weeks of endurance training. Another eight participants (age 23+/-4 years; body mass 72.7+/-12.5 kg) acted as non-training controls. Before and after the training intervention, all participants completed: (1) a standard multi-stage treadmill test for the assessment of VO2max, running speed at the lactate threshold and running speed at a reference blood lactate concentration of 3 mmol x l(-1); and (2) the lactate minimum speed test, which involved two supramaximal exercise bouts and an 8 min walking recovery period to increase blood lactate concentration before the completion of an incremental treadmill test. Additionally, a subgroup of eight participants from the training intervention completed a series of constant-speed runs for determination of running speed at the maximal lactate steady state. The test protocols were identical before and after the 6 week intervention. The control group showed no significant changes in VO2max, running speed at the lactate threshold, running speed at a blood lactate concentration of 3 mmol x l(-1) or the lactate minimum speed. In the training group, there was a significant increase in VO2max (from 47.9+/-8.4 to 52.2+/-2.7 ml x kg(-1) x min(-1)), running speed at the maximal lactate steady state (from 13.3+/-1.7 to 13.9+/-1.6 km x h(-1)), running speed at the lactate threshold (from 11.2+/-1.8 to 11.9+/-1.8 km x h(-1)) and running speed at a blood lactate concentration of 3 mmol x l(-1) (from 12.5+/-2.2 to 13.2+/-2.1 km x h(-1)) (all P < 0.05). Despite these clear improvements in aerobic fitness, there was no significant difference in lactate minimum speed after the training intervention (from 11.0+/-0.7 to 10.9+/-1.7 km x h(-1)). The results demonstrate that the lactate minimum speed, when assessed using the same exercise protocol before and after 6 weeks of aerobic exercise training, is not sensitive to changes in endurance capacity.  相似文献   
5.
美国医学院校的课程整合改革方兴未艾.加州大学旧金山分校医学院从2001级新生开始对课程体系进行大幅调整,本研究调查了该校参与改革的不同群体,包括教育改革的领导者、受到直接影响的学生、新建课程的负责人等对课程改革的态度,了解其对课程整合实施一年内的成绩和挑战的看法.结果表明,他们对跨学科教学、跨学科系室协作、课程关联的建立、课程内容的排序及框架构建等四个主题有相同的看法,也有不小的分歧.  相似文献   
6.
Conconi et al. (1982) reported that an observed deviation from linearity in the heart rate-running velocity relationship determined during a field test in runners coincided with the ‘lactate threshold’. The aim of this study was to assess the validity of the original Conconi test using conventional incremental and constant-load laboratory protocols. Fourteen trained male distance runners (mean ± s : age 22.6 ±3.4 years; body mass 67.6±4.8 kg; peak [Vdot] O 2 66.3 ± 4.7 ml kg -1 min -1) performed a standard multi-stage test for determination of lactate turnpoint and a Conconi test on a motorized treadmill. A deviation from linearity in heart rate was observed in nine subjects. Significant differences were found to exist between running velocity at the lactate turnpoint (4.39 ± 0.20 ms -1) and at deviation from linear heart rate (5.08 ± 0.25 ms -1) (P < 0.01), and between heart rate at the lactate turnpoint (172 ± 10 beats min -1) and at deviation from linearity (186 ± 9 beats min -1) (P < 0.01). When deviation of heart rate from linearity was evident, it occurred at a systematically higher intensity than the lactate turnpoint and at approximately 95% of maximum heart rate. These results were confirmed by the physiological responses of seven subjects, who performed two constant-velocity treadmill runs at 0.14 ms -1 below the running velocity at the lactate turnpoint and that at which the heart rate deviated from linearity. For the lactate turnpoint trial, the prescribed 30 min exercise period was completed by all runners (terminal blood lactate concentration of 2.4 ± 0.5 mM ), while the duration attained in the trial for which heart rate deviated from linearity was 15.9 ± 6.7 min (terminal blood lactate concentration of 8.1 ± 1.8 mM). We concluded that the Conconi test is invalid for the non-invasive determination of the lactate turnpoint and that the deviation of heart rate from linearity represents the start of the plateau at maximal heart rate, the expression of which is dependent upon the specifics of the Conconi test protocol.  相似文献   
7.
The aim of this study was to establish the validity of the breakpoint in breathing frequency for the assessment of the lactate threshold and the ventilatory threshold during incremental running exercise. Twelve trained runners (mean +/- s: age 29 +/- 8 years; body mass 68.7 8.8 kg; V O 2m ax 57.9 +/- 4.1 ml . kg -1 . min -1 ) performed randomly assigned incremental treadmill tests on separate days. In addition to the assessment of the V O 2m ax (Test 1), the subjects performed two standard multi-stage treadmill tests (4-min stages) for the assessment of the lactate threshold while wearing (Test 2) and not wearing (Test 3) a standard mouthpiece and noseclip arrangement. Breathing frequency was measured by a thermistor, which was positioned in the back of the mouthpiece for Test 2, and fixed 3 cm in front of the mouth using a headband and flexible wiring for Test 3. All exercise tests were recorded on videotape and mean breathing frequency and stride rate were calculated for the last minute of each stage from real-time playback of the videotapes. The breathing frequency breakpoint was determined in six subjects only for Test 2 and in five subjects only for Test 3. For Test 2, there were no differences between the breakpoint in breathing frequency (14.7 +/- 0.9 km . h - 1), the lactate threshold (14.7 +/- 0.9 km . h -1 ) and the ventilatory threshold (14.7 +/- 1.1 km . h -1 ). For Test 3, the breakpoint in breathing frequency (14.0 +/- 1.0 km . h -1 ) was not appreciably different from the lactate threshold (14.7 +/- 1.2 km . h -1 ). Hey plots showed marked interindividual differences in the responses of breathing frequency and tidal volume to exercise. In four subjects, the ventilatory threshold was mediated by a non-linear increase in tidal volume, with breathing frequency either increasing in a linear manner (n = 1) or remaining constant owing to entrainment of breathing frequency to cadence (n = 3). We conclude that the breakpoint in breathing frequency does not provide a valid method for the field-based assessment of the lactate or ventilatory thresholds in most subjects for running exercise.  相似文献   
8.
The aim of this study was to examine the variability of the oxygen uptake (VO2) kinetic response during moderate- and high-intensity treadmill exercise within the same day (at 06:00, 12:00 and 18:00 h) and across days (on five occasions). Nine participants (age 25 +/- 8 years, mass 70.2 +/- 4.7 kg, VO2max 4137 +/- 697 ml x min(-1); mean +/- s) took part in the study. Six of the participants performed replicate 'square-wave' rest-to-exercise transitions of 6 min duration at running speeds calculated to require 80% VO2 at the ventilatory threshold (moderate-intensity exercise) and 50% of the difference between VO2 at the ventilatory threshold and VO2max (50% delta; high-intensity exercise) on 5 different days. Although the amplitudes of the VO2 response were relatively constant (coefficient of variation approximately 6%) from day to day, the time-based parameters were more variable (coefficient of variation approximately 15 to 30%). All nine participants performed replicate square-waves for each time of day. There was no diurnal effect on the time-based parameters of VO2 kinetics during either moderate- or high-intensity exercise. However, for high-intensity exercise, the amplitude of the primary component was significantly lower during the 12:00 h trial (2859 +/- 142 ml x min(-1) vs 2955 +/- 135 ml x min(-1) at 06:00 h and 2937 +/- 137 ml x min(-1) at 18:00 h; P < 0.05), but this effect was eliminated when expressed relative to body mass. The results of this study indicate that the amplitudes of the VO2 kinetic responses to moderate- and high-intensity treadmill exercise are similar within and across test days. The time-based parameters, however, are more variable from day to day and multiple transitions are, therefore, recommended to increase confidence in the data.  相似文献   
9.
The aims of this study were to quantify the effects of factors such as mode of exercise, body composition and training on the relationship between heart rate and physical activity energy expenditure (measured in kJ?·?min?1) and to develop prediction equations for energy expenditure from heart rate. Regularly exercising individuals (n = 115; age 18?–?45 years, body mass 47?–?120?kg) underwent a test for maximal oxygen uptake ([Vdot]O2max test), using incremental protocols on either a cycle ergometer or treadmill; [Vdot]O2max ranged from 27 to 81?ml?·?kg?1?·?min?1. The participants then completed three steady-state exercise stages on either the treadmill (10?min) or the cycle ergometer (15?min) at 35%, 62% and 80% of [Vdot]O2max, corresponding to 57%, 77% and 90% of maximal heart rate. Heart rate and respiratory exchange ratio data were collected during each stage. A mixed-model analysis identified gender, heart rate, weight, [Vdot]2max and age as factors that best predicted the relationship between heart rate and energy expenditure. The model (with the highest likelihood ratio) was used to estimate energy expenditure. The correlation coefficient (r) between the measured and estimated energy expenditure was 0.913. The model therefore accounted for 83.3% (R 2) of the variance in energy expenditure in this sample. Because a measure of fitness, such as [Vdot]O2max, is not always available, a model without [Vdot]O2max included was also fitted. The correlation coefficient between the measured energy expenditure and estimates from the mixed model without [Vdot]O2max was 0.857. It follows that the model without a fitness measure accounted for 73.4% of the variance in energy expenditure in this sample. Based on these results, we conclude that it is possible to estimate physical activity energy expenditure from heart rate in a group of individuals with a great deal of accuracy, after adjusting for age, gender, body mass and fitness.  相似文献   
10.
Books reviews     
Coaching Children in Sport: Principles and Practice. M. Lee (ed.), E. & F.N. Spon, London, 1993. xiv + 311 pp., £16.99 (pb), ISBN 0 419 18250 0.

Clinical Sports Medicine. P. Brukner and K. Khan, McGraw‐Hill, Sydney, 1993. 697 pp., £48.00 (hb), ISBN 0 07 452852 1.

The Physiology of Sport and Exercise. J.H. Wilmore and D.L. Costill, Human Kinetics, Champaign, IL, 1994. x + 549 pp., £40.00 (hb), ISBN 0 87322 693 3.

Neuromechanical Basis of Kinesiology, 2nd Edn. R.M. Enoka, Human Kinetics, Champaign, IL, 1994. xiii + 466 pp., £40.00 (hb), ISBN 0 87322 665 8.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号