首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 953 毫秒
1.
The purpose of this study was to determine the between day reliability of power-time measures calculated with data collected using the linear position transducer or the force plate independently, or a combination of the two technologies. Twenty-five male rugby union players performed three jump squats on two occasions one week apart. Ground reaction forces were measured via a force plate and position data were collected using a linear position transducer. From these data, a number of power-time variables were calculated for each method. The force plate, linear position transducer and a combined method were all found to be a reliable means of measuring peak power (ICC = 0.87‐0.95, CV = 3.4%‐8.0%). The absolute consistency of power-time measures varied between methods (CV = 8.0%‐53.4%). Relative consistency of power-time measures was generally comparable between methods and measures, and for many variables was at an acceptable level (ICC = 0.77‐0.94). Although a number of time-dependent power variables can be reliably calculated from data acquired from the three methods investigated, the reliability of a number of these measures is below that which is acceptable for use in research and for practical applications.  相似文献   

2.
ABSTRACT

When new protocols are developed, there is a requirement to investigate test–retest reliability of measures for valid use and interpretation of data in research and practice. Therefore, the aim of this investigation was to determine the inter-day reliability of the cable put and seated rotation assessment protocols. On three occasions, nine resistance-trained men performed cable puts and cable rotations at different loads between 6 and 42 kg on a commercially available cable cross over machine. Load stack movement was recorded using a PT5A linear position transducer from which all kinematic and kinetic variables were calculated. Reliability was excellent for peak velocity and displacement based on intraclass correlation coefficient (ICC) and coefficient of variation (CV) across the majority of loads and movements (cable put: ICC = 0.92 to 0.99, CV = 3.1% to 8.6%; cable seated rotation: ICC = 0.76 to 0.99, CV = ?1.7% to 16.1%). However, kinetic variables demonstrated inadequate reliability across the majority of days, loads and movements (ICC = 0.70, CV >10%). It was concluded that peak velocity is a reliable kinematic measure to assess muscular capability from cable put and seated rotation protocols; however, kinetic measures are too variable to provide reliable outputs across testing occasions.  相似文献   

3.
Abstract

This study assessed the reliability and validity of segment measured accelerations in comparison to front foot contact (FFC) ground reaction force (GRF) during the delivery stride for cricket pace bowlers. Eleven recreational bowlers completed a 30-delivery bowling spell. Trunk- and tibia-mounted inertial measurement units (IMUs) were used to measure accelerations, converted to force, for comparisons to force plate GRF discrete measures. These measures included peak force, impulse and the continuous force–time curve in the vertical and braking (horizontal) planes. Reliability and validity was determined by intra-class correlation coefficients (ICC), coefficient of variation (CV), Bland–Altman plots, paired sample t-tests, Pearson’s correlation and one-dimensional (1D) statistical parametrical mapping (SPM). All ICC (0.90–0.98) and CV (4.23–7.41%) were acceptable, except for tibia-mounted IMU braking peak force (CV = 12.44%) and impulse (CV = 18.17%) and trunk vertical impulse (CV = 17.93%). Bland–Altman plots revealed wide limits of agreement between discrete IMU force signatures and force plate GRF. The 1D SPM outlined numerous significant (p < 0.01) differences between trunk- and tibia-located IMU-derived measures and force plate GRF traces in vertical and braking (horizontal) planes. The trunk- and tibia-mounted IMUs appeared to not represent the GRF experienced during pace bowling FFC when compared to a gold-standard force plate.  相似文献   

4.
The current study aimed to assess the validity and test–retest reliability of a linear position transducer when compared to a force plate through a counter-movement jump in female participants. Twenty-seven female recreational athletes (19 ± 2 years) performed three counter-movement jumps simultaneously using the linear position transducer and force plate for validity. In addition, 11 elite female athletes (23 ± 6 years) performed 3 counter-movement jumps with the linear position transducer on three separate days for test–retest reliability. Pearson correlations for jump height between the devices were at a high level (= .90), with the linear position transducer overestimating jump height by 7.0 ± 2.8 cm. The reliability measured by the linear position transducer resulted in a mean intraclass correlation of .70 for jump height, .90 for peak velocity, and .91 for mean velocity. The linear position transducer was reliable for measuring counter-movement jumps in elite female athletes; however, caution should be taken for one-off jump measures as it may over-estimate jump height.  相似文献   

5.
This study aimed to (1) assess the reliability of the force, velocity, and power output variables measured by a force plate and a linear velocity transducer (LVT) for both the unconstrained and constrained loaded countermovement jump (CMJ), and (2) examine the effect of both the CMJ type and the measurement method on the magnitudes of the same variables. Twenty-three men were tested on the free CMJ and the CMJ constrained by a Smith machine. Maximum values of force, velocity, and power were recorded by a force plate and by a LVT attached to a bar loaded by 17, 30, 45, 60, and 75 kg. The reliability of all mechanical variables proved to be high (ICC > 0.70; CV < 10%) and similar for two CMJ types. However, force plate-derived measures displayed greater reliability than the LVT. The LVT also markedly overestimated the magnitudes of the mechanical variables, particularly at lower external loads. Therefore, although both jump types and both methods could be acceptable for routine testing, we recommend the force platform due to a higher reliability and more accurate magnitudes of the obtained variables. The unconstrained loaded CMJ could also be recommended due to the simpler equipment needed.  相似文献   

6.
The purpose of this study was to quantify the reliability of kinematic and kinetic variables using a sample of pre-peak-height-velocity (PHV) male athletes sprinting on a non-motorised treadmill. Following variables were measured and their normative data presented, average and peak velocity, average and peak power, average and peak horizontal force, average and peak vertical force, average step frequency, average step length, average work. Twenty-five participants performed three 5-s all-out sprints from a standing split start on a non-motorised treadmill on three separate occasions. Per cent change in the means (-3.66 to 3.35%) and coefficients of variation (0.56–7.81%) were thought reliable for all variables. However, average step rate, average horizontal force and average vertical force did not meet the standards (≥0.70) set for acceptable intraclass correlation coefficients (ICC). Due to the homogeneous group, it was expected to receive low ICC values. Therefore, youth sprinting performance can be tested reliably on a non-motorised treadmill, especially if the per cent change in the mean and CV are deemed the important reliability measures. Normative data are given for the participant’s age as well as their maturity level for kinematic and kinetic variables.  相似文献   

7.
ABSTRACT

This study aimed to compare the reliability and magnitude of velocity variables between 3 variants of the bench press (BP) exercise in participants with and without BP training experience. Thirty males, 15 with and 15 without BP experience, randomly performed 3 variants of the BP on separate sessions: (I) concentric-only, (II) fast-eccentric and (III) controlled-eccentric. The mean velocity (MV) and maximum velocity (Vmax) of the concentric phase were collected against 3 loads (≈30%1RM, 50%1RM, and 75%1RM) with a linear velocity transducer. Reliability was high regardless of the variable, BP variant, and load (coefficient of variation [CV] ≤ 4.47%, intraclass correlation coefficient [ICC] ≥ 0.87). The comparison of the CVs suggested a higher reliability for the fast-eccentric BP (8 out of 12 comparisons), followed by the concentric-only BP (5 out of 12 comparisons), and finally the controlled-eccentric BP (never provided a higher reliability). No differences in reliability were observed between experienced (CV ≤ 4.71%; ICC ≥ 0.79) and non-experienced (CV ≤ 6.29%; ICC ≥ 0.76) participants. The fast-eccentric BP provided the highest MV (p < 0.05) and no differences were observed for Vmax. These results support the assessment of movement velocity during the fast-eccentric BP even in participants without experience.  相似文献   

8.
This study aimed to correlate, compare, and determine the reliability of force, velocity, and power values collected with a force plate (FP) and a linear transducer during loaded jumps. Twenty-three swimmers performed an incremental loading test at 25, 50, 75, and 100% of their own body weight on a FP. A linear velocity transducer (LVT) was attached to the bar to assess the peak and the mean values of force, velocity, and power. Both the peak variables (r = 0.94 – 0.99 for peak force, r = 0.83 – 0.91 for peak velocity, and r = 0.90–0.94 for peak power; p < 0.001) and the mean variables (r = 0.96–0.99 for mean force, r = 0.87–0.89 for mean velocity, and r = 0.93–0.96 for mean power; p < 0.001) were strongly correlated between both measurement tools. Differences in the shape of the force-, velocity-, and power-time curves were observed. The LVT data showed a steeper increase in these variables at the beginning of the movement, while the FP recorded larger values in the latter part. Peak values were more reliable than mean values. These results suggest that the LVT is a valid tool for the assessment of loaded squat jump.  相似文献   

9.
This study aimed to assess the reliability, usefulness and construct validity of the newly developed Combined Basketball Skill Test (CBST). Fifteen recreational (age = 22.8 ± 4.2 y, stature = 184.8 ± 6.5 cm, body mass = 81.6 ± 9.6 kg, training experience = 9.8 ± 5.3 y) and fifteen semiprofessional (age = 18.9 ± 3.3 y, stature = 190.5 ± 8.1 cm, body mass = 84.2 ± 11.2 kg, training experience = 11.1 ± 3.5 y) players volunteered to participate in this study. Test–retest reliability and usefulness were examined for recreational players, while construct validity was evaluated comparing the two player groups. The CBST is composed of 12 trials and its outcome measures include: completion time (sum of the 12 trial times); penalty time (sum of the times from the 12 trials); performance time (completion time + penalty time) and total number of errors. Relative reliability analysis showed acceptable ICC values (i.e. ≥0.70) in all the studied variables. Absolute reliability analysis showed a CV < 5% for completion (1.6%) and performance (2.0%) time, while a CV >5% is reported for the remaining variables. The usefulness of the test was considered “Marginal” and “Good” when comparing TE values with SWC02 and SWC05, respectively for all the studied variables. Likely and very likely differences were shown between recreational and semiprofessional players in all investigated variables. Results showed that the CBST is reliable, useful to detect moderate changes and valid to assess basketball skills.  相似文献   

10.
11.
The aim of this study was to evaluate the reliability of two long jump tasks and their ability to predict 10 m sprint performance in elite adolescent female athletes. Eight junior national-level female track and field athletes completed three standing (SLJ) and reactive long jumps (RLJ) on portable force plates, followed by three 10 m sprints. Intra-class correlation coefficients (ICC) and coefficients of variation (CV) were calculated to examine reliability. Linear regression results identified the best predictor of average and best 10 m sprint time from the jump kinematic and kinetic measures. The ICCs and CVs indicated good reliability for the majority of kinetic measures however, better reliability was reported for the SLJ. The SLJ was a good predictor of best and average 10 m sprint time, with average horizontal power the best predictor of performance (best; R2 = 0.751, p = 0.003, Standard Error of Estimate (SEE)% = 2.2 average; R2 = 0.708, p = 0.005, SEE% = 2.5).  相似文献   

12.
The purpose of this study was to quantify the inter-session reliability of force–velocity–power profiling and estimated maximal strength in youth. Thirty-six males (11–15 years old) performed a ballistic supine leg press test at five randomized loads (80%, 100%, 120%, 140%, and 160% body mass) on three separate occasions. Peak and mean force, power, velocity, and peak displacement were collected with a linear position transducer attached to the weight stack. Mean values at each load were used to calculate different regression lines and estimate maximal strength, force, velocity, and power. All variables were found reliable (change in the mean [CIM] = ? 1 to 14%; coefficient of variation [CV] = 3–18%; intraclass correlation coefficient [ICC] = 0.74–0.99), but were likely to benefit from a familiarization, apart from the unreliable maximal force/velocity ratio (CIM = 0–3%; CV = 23–25%; ICC = 0.35–0.54) and load at maximal power (CIM = ? 1 to 2%; CV = 10–13%; ICC = 0.26–0.61). Isoinertial force–velocity–power profiling and maximal strength in youth can be assessed after a familiarization session. Such profiling may provide valuable insight into neuromuscular capabilities during growth and maturation and may be used to monitor specific training adaptations.  相似文献   

13.
ABSTRACT

Anaerobic performance in youth has received little attention partly due to the lack of a “gold-standard” measurement. However, force-velocity-power (F-v-P) profiling recently showed high reliability and validity in trained adults. Therefore, the aim was to determine the reliability of F-v-P profiling in children and adolescents. Seventy-five children (60 boys, 15 girls; age: 14.1 ± 2.6 years) completed three 30 m sprints. Velocity was measured at 46.875 Hz using a radar device. The F-v-P profile was fitted to a velocity-time curve allowing instantaneous power variables to be calculated. Reliability was assessed using the intra-class correlation coefficient (ICC), coefficient of variation (CV), standard error of measurement (SEM) and smallest worthwhile change (SWC). High reliability was evident for absolute peak (Ppeak) and mean power (Pmean), Ppeak and Pmean expressed relative to body mass, peak and mean velocity, 30 m sprint time, peak horizontal force (F0), relative F0, mechanical efficiency index and fatigue rate (ICC: 0.75–0.88; CV: 1.9–9.4%) with time to peak power demonstrating moderate reliability (ICC: 0.50; CV: 9.5%). The F-v-P model demonstrated at least moderate reliability for all variables. This therefore provides a potential alternative for paediatric researchers assessing sprint performance and the underlying kinetics.  相似文献   

14.
This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants’ feet. The velocity of the ‘body + lifted mass’ system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p < 0.05). Within sessions and between sessions, mean and peak forces during DHP showed a strong agreement (CV < 3%, ICC > 0.94), mean and peak velocities showed a good agreement (CV < 9%, 0.78 < ICC < 0.92). It was concluded that DHP performance and its force-velocity relationships are highly reliable and can therefore be utilised as a tool to characterise individuals’ muscular profiles.  相似文献   

15.
This study aimed to assess the validity and reliability of jump assessments using the MyJump2 application. Eleven junior athletes (15 ± 1.4 years) performed five countermovement (CMJ) and drop jumps (DJ) measured simultaneously by a force platform and MyJump2. Additionally, intra- and inter-day reliability was assessed over two sessions, 7 days apart. Extremely high agreement between MyJump2 and the force platform (intra-class correlation coefficient, ICC ≥ 0.99) and the intra- and inter-operator agreement (ICC = 0.98–0.99) confirmed the validity and reliability of MyJump2. Mean typical errors (coefficient of variation percentage, CV%) within the first and second sessions were 4.9% and 4.5% respectively for CMJs, and 8.0% to 11.8% for DJ outcomes. CMJ height held acceptable inter-day reliability (CV < 10%; ICC > 0.8), while DJ did not. Results supported MyJump2 to be a valid and reliable tool for assessing jumps; however, with variability in DJs in this cohort, appropriate caution should be taken if including in a junior assessment battery.  相似文献   

16.
Quantifying soft tissue motion following impact is important in human motion analysis as soft tissues attenuate potentially injurious forces resulting from activities such as running and jumping. This study determined the reliability of leg soft tissue position and velocity following heel impacts. A grid of black dots was applied to the skin of the right leg and foot (n = 20). Dots were automatically detected (ProAnalyst®) from high-speed records of pendulum and drop impacts. Three trained measurers selected columns of dots on each participant for analysis; one measurer 6 months later. Between- and within-measurer differences in kinematic variables were all relatively small (<0.8 cm for position; <3.7 cm/s for velocity) between-measurers and (<0.5 cm for position; <2.6 cm/s for velocity) within-measurer. Good (coefficients of variation (CV) ≤ 10%) to acceptable (CV > 10% and ≤20%) reliability was shown for 95% of the position measures, with mean CVs of 10% and 11% within-measurers and between-measures, respectively. Velocity measures were less reliable; 40% of the measures showed good to marginal (CV > 20% and ≤30%) reliability. This study established that leg soft tissue position data from skin markers could be obtained with good to acceptable reliability following heel impacts. Velocity data were less reliable but still acceptable in many cases.  相似文献   

17.
There is a need for reliable analysis techniques for kinetic data for coaches and sport scientists who employ athlete monitoring practices. The purpose of the study was: (1) to determine intra- and inter-rater reliability within a manual-based kinetic analysis program; and (2) to determine test-retest reliability of an algorithm-based kinetic analysis program. Five independent raters used a manual analysis program to analyse 100 isometric mid-thigh pull (IMTP) trials obtained from previously collected data. Each trial was analysed three times. The same IMTP trials were analysed using an algorithm-based analysis software. Variables measured were peak force, rate of force development from 0 to 50 ms (RFD50) and RFD from 0 to 200 ms (RFD200). Intraclass correlation coefficients (ICC) and coefficient of variation (CV) were used to assess intra- and inter-rater reliability. Nearly perfect reliability was observed for the manual-based (ICC > 0.92). However, poor intra- and inter-rater CV was observed for RFD (CV > 16.25% and CV > 32.27%, respectively). The algorithm-based method resulted in perfect reliability in all measurements (ICC = 1.0, CV = 0%). While manual methods of kinetic analysis may provide sufficient reliability, the perfect reliability observed within the algorithm-based method in the current study suggest it is a superior method for use in athlete monitoring programs.  相似文献   

18.
This study aimed to explore the strength of the force–velocity (FV) relationship of lower limb muscles and the reliability of its parameters (maximum force [F0], slope [a], maximum velocity [V0], and maximum power [P0]). Twenty-three men were tested in two different jump types (squat and countermovement jump: SJ and CMJ), performed under two different loading conditions (free weight and Smith machine: Free and Smith) with 0, 17, 30, 45, 60, and 75?kg loads. The maximum and averaged values of F and V were obtained for the FV relationship modelling. All FV relationships were strong and linear independently whether observed from the averaged across the participants (r?≥?0.98) or individual data (r?=?0.94–0.98), while their parameters were generally highly reliable (F0 [CV: 4.85%, ICC: 0.87], V0 [CV: 6.10%, ICC: 0.82], a [CV: 10.5%, ICC: 0.81], and P0 [CV: 3.5%, ICC: 0.93]). Both the strength of the FV relationships and the reliability of their parameters were significantly higher for (1) the CMJ over the SJ, (2) the Free over the Smith loading type, and (3) the maximum over the averaged F and V variables. In conclusion, although the FV relationships obtained from all the jumps tested were linear and generally highly reliable, the less appropriate choice for testing the FV relationship could be through the averaged F and V data obtained from the SJ performed either in a Free weight or in a Smith machine. Insubstantial differences exist among the other combinations tested.  相似文献   

19.
Little is known about the reliability, validity and smallest detectable differences of selected kinetic and temporal variables recorded by the Zebris FDM-THQ instrumented treadmill especially during running. Twenty male participants (age = 31.9 years (±5.6), height = 1.81 m (±0.08), mass = 80.2 kg (±9.5), body mass index = 24.53 kg/m2 (±2.53)) walked (5 km/h) and ran (10 and 15 km/h) on an instrumented treadmill, wearing running shoes fitted with Pedar-X insoles. A test-double retest protocol was conducted over two consecutive days. Maximal vertical force (Fmax), contact time (CT) and flight time (FT) data from 10 consecutive steps were collected. Within- and between-day reliability, smallest detectable differences (SDD) and validity (95% limits of agreement (LOA)) were calculated. ICC values for the Zebris for Fmax were acceptable (ICC ≥ 0.7) while CT and FT reliability indices were predominantly good (ICC ≥ 0.8) to excellent (ICC ≥ 0.9). The Zebris significantly underestimated Fmax when compared with the Pedar-X. The 95% LOA increased with speed. SDD ranged between 96 N and 169 N for Fmax, 0.017s and 0.055s for CT and 0.021s and 0.026s for FT. In conclusion, Zebris reliability was acceptable to excellent for the variables examined, but inferior in comparison with Pedar-X. With increased running speeds, a bias effect (underestimation) existed for the Zebris compared with Pedar-X.  相似文献   

20.
This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20–70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load–power relationship compared to the load–velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏